Description
Polyester suture Premisut Prime with pledget for ophthalmology and neurosurgery
The polyester suture Premisut Prime with double ½ circle needle, cylindrical body, 26 mm trocar point and 6x3x1.5 mm pledget is the choice of surgical departments seeking a high-performance non-absorbable thread with smooth handling and predictable tissue behaviour. Presented in USP 2/0 gauge, green colour and 90 cm thread, it allows a unified criterion in demanding specialties such as ophthalmology and neurosurgery, as well as in the approximation and ligation of soft tissues. It is supplied in a box of 12 units sterilised by ethylene oxide, ready to use at the time of the procedure and designed for centralised purchasing of the surgical block.
Technical explanation
The thread is composed of fine polyethylene terephthalate (polyester) fibres braided into a compact multifilament structure and coated with silicone, which improves passage through tissue, facilitates knot advancement and reduces tissue trauma. Being non-absorbable, it does not degrade by the enzymatic action of the body: it maintains its tensile strength for a prolonged period, providing wound support for more than three months while gradual encapsulation by fibrous connective tissue occurs.
The ½ circle needle allows suturing in wide spaces with controlled rotational movements, while the trocar point (tapercut) combines the penetration of a cutting needle with the minimal aggression of a round needle: it passes through dense or fibrous tissues without tearing, reducing bleeding and tissue injury. The double needle configuration (2xHRT26) allows continuous sutures with two hemi-arcs without repositioning the needle in the needle holder, optimising surgical time. The 6x3x1.5 mm pledget incorporated on the thread increases the bearing surface of the stitch, distributes tension over the tissue and prevents cutting of the tissue bed, especially useful in friable or oedematous tissues.
Technical specifications
| Material | Braided multifilament polyester (polyethylene terephthalate) |
| Coating | Silicone (polyester – polyethylene) |
| Suture type | Non-absorbable, synthetic coated multifilament |
| Gauge | USP 2/0 (EP 3) |
| Thread length | 90 cm |
| Needle shape | 1/2 circle |
| Tip type | Cylindrical body with trocar point (tapercut) |
| Needle configuration and size | Double needle 2xHRT26 (Premilloy stainless steel), 26 mm |
| Pledget | 6 x 3 x 1.5 mm |
| Colour | Green |
| Behaviour | No absorption; gradual encapsulation; tissue support exceeding 3 months |
| Tensile strength | Permanent; exceeds USP and EP requirements |
| Sterilisation | Ethylene oxide (EO) |
| Presentation | Box of 12 units |
| Regulatory standard | Conforms to Regulation (EU) 2017/745 (MDR) |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| References | P853HRT2620PL6-2 (manufacturer) / AMP853HRT2620PL6-2 (Cahnos) |
Equivalences and cross-references
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Atlas Medical (Premisut PRIME) | Polyester 1/2 trocar 2xHRT26, 2/0 green, 90 cm with pledget 6x3x1.5 mm | P853HRT2620PL6-2 / AMP853HRT2620PL6-2 | Reference analysed / direct equivalent | Same family, measurements and material; official factory code P853HRT2620PL6-2; AMP853HRT2620PL6-2 is the Cahnos distribution reference. |
| Atlas Medical (Premisut PRIME) | Polyester 1/2 trocar 2xHRT26, 2/0 green, 90 cm (without pledget) | AMP853HRT2620-2 | Family equivalence | Same configuration, gauge and length; differs by the absence of pledget. Not interchangeable 1:1. |
| Atlas Medical (Premisut PRIME) | Polyester 1/2 trocar 2xHRT26, 2/0 green, 4×90 cm with pledget | AMP853HRT2620.4PL6-2 | Family equivalence | Multipack of 4 threads of 90 cm with pledget and 26 mm needle. Not interchangeable 1:1 in presentation. |
| Atlas Medical (Premisut PRIME) | Polyester 1/2 trocar 2xHRT36, 2/0 green, 90 cm | AMP853HRT3620 | Family equivalence | Same configuration, gauge and length; 36 mm needle instead of 26 mm and without pledget. Not interchangeable 1:1. |
| B. Braun | PremiCron (braided polyester coated with silicone) 2/0 EP 3, 90 cm, double needle 2xHR26, green | C0026816 | Comparable by category, not interchangeable 1:1 | Same EP 3 gauge, green 90 cm thread, double 26 mm needle (HR26, cylindrical-conical point) and silicone coating; Premisut provides trocar point and pledget. Verify regulations and availability. |
| Ethicon (Johnson & Johnson MedTech) | Ethibond Excel (braided polyester coated with polybutylate) USP 2/0, 90 cm, double 26 mm 1/2 circle tapercut needle, green | X966H | Comparable by category, not interchangeable 1:1 | Non-absorbable coated polyester multifilament with similar indications; the coating differs (polybutylate versus silicone) and it does not incorporate a pledget. Verify geometry and gauge before substituting. |
There is no equivalence table validated by the manufacturer that cross-references the Premisut reference with other brands; the cross-references with B. Braun and Ethicon are functional category comparisons pending official confirmation. Consult the technical department before use in tendering or substitution of references.
Selection tips and variants of interest
- Delicate or friable tissues: the 6x3x1.5 mm pledget distributes tension and prevents tissue cutting; if the protocol does not require stitch reinforcement, the variant without pledget (AMP853HRT2620-2) is the natural alternative.
- Ophthalmology and neurosurgery: the USP 2/0 gauge with double needle is ideal for continuous sutures and ligatures in delicate tissues; the green colour facilitates visibility of the thread on the surgical field.
- Surgical field: for wider spaces, the 36 mm needle variant (AMP853HRT3620) is available and, for very restricted spaces, the 17 mm one (AMP853HRT1720-2).
- Centralised purchasing: for high consumption, consider the multipack presentations of 4 x 90 cm with pledget (AMP853HRT2620.4PL6-2) and check minimum order and storage conditions.
- Before changing brand: always check needle angle (1/2), size (26 mm), point type (trocar/tapercut), double needle configuration, USP/EP gauge, exact thread material and coating in the alternative manufacturer’s technical data sheet.
- Storage: sterile product by ethylene oxide; respect the storage conditions and the expiry date of the packaging.





Reviews
There are no reviews yet.