Description
1. Introduction
The polyester suture Premisut Prime in a 1/2 circle configuration with double needle and 17 mm trocar point (TAPERCUT) is the choice of professionals seeking a high-performance non-absorbable thread with smooth handling and predictable tissue behaviour. Presented in USP 2/0 gauge, white colour and 90 cm of thread, it allows surgical services to standardise criteria in procedures for approximating and ligating soft tissues, as well as in demanding specialties such as ophthalmology and neurosurgery. It is supplied in a box of 12 units sterilised by ethylene oxide, ready for use at the time of the procedure and designed for centralised purchasing by the surgical block.
2. Technical explanation
The thread is composed of fine fibres of polyethylene terephthalate (polyester) braided into a compact multifilament structure and coated with silicone, which improves passage through tissue, facilitates knot advancement and reduces tissue trauma. Being non-absorbable, it does not degrade through the body’s enzymatic action: it maintains its tensile strength over a prolonged period, providing wound support for more than three months while gradual encapsulation by fibrous connective tissue occurs.
The 1/2 circle needle allows suturing in wide or restricted surgical fields with controlled rotational movements, while the trocar point (TAPERCUT) combines the penetration of a cutting needle with the minimal aggression of a round needle: it passes through dense or fibrous tissues without tearing, reducing bleeding and tissue injury. The double needle configuration (2xHRT17) allows continuous sutures with two hemi-arcs without repositioning the needle in the needle holder, optimising surgical time.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Material | Braided multifilament polyester (polyethylene terephthalate) |
| Coating | Silicone (polyester – polyethylene) |
| Suture type | Non-absorbable, synthetic coated multifilament |
| Gauge | USP 2/0 (EP 3) |
| Thread length | 90 cm |
| Needle shape | 1/2 circle |
| Tip type | Cylindrical body with trocar point (TAPERCUT) |
| Needle configuration and size | Double needle 2xHRT17 (stainless steel), 17 mm |
| Colour | White |
| Absorption | No absorption; gradual encapsulation; tissue support exceeding 3 months |
| Tensile strength | High and permanent; exceeds USP and EP requirements |
| Sterilisation | Ethylene oxide (EO) |
| Presentation | Box of 12 units |
| Shelf life | 5 years |
| Regulatory standard | Compliant with Regulation (EU) 2017/745 (MDR); exceeds USP and EP requirements |
| Indications | Approximation of soft tissues, ligatures, ophthalmology, neurosurgery and general surgery |
| Reference Cahnos | AMP873HRT1720-2 (official Atlas Medical factory code: L873HRT1720-2) |
4. Equivalences and Cross-References
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Atlas Medical (Premisut Prime) | Polyester 1/2 TAPERCUT 2xHRT17, 2/0 white, 90 cm | L873HRT1720-2 | Reference analysed / direct equivalent | Same family, measurements and material; the official factory code is L873HRT1720-2 and the Cahnos SKU AMP873HRT1720-2 matches the configuration literally. |
| Atlas Medical (Premisut Prime) | Polyester 1/2 TAPERCUT 2xHRT17, 2/0 green, 90 cm | AMP853HRT1720-2 / L853HRT1720-2 | Family equivalence | Same needle, gauge and length; only the thread colour differs. Not 1:1 interchangeable if colour is a protocol requirement. |
| Atlas Medical (Premisut Prime) | Polyester 1/2 TAPERCUT 2xHRT17, 4/0 white, 90 cm | AMP873HRT1740-2 | Family equivalence | Same needle and geometry; finer 4/0 gauge. Not 1:1 interchangeable. |
| Atlas Medical (Premisut Prime) | Polyester 1/2 TAPERCUT 2xHRT17, 2/0 green, 4×90 cm | AMP853HRT1720.4-2 | Family equivalence | Same configuration in a multipack of 4 threads of 90 cm. Not 1:1 interchangeable in presentation. |
| Ethicon (Johnson & Johnson MedTech) | Ethibond Excel (polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Coated non-absorbable multifilament polyester with similar indications; verify 1/2 TAPERCUT 17 mm geometry, double needle configuration and USP/EP gauge. |
| B. Braun | Premicron / Dagrofil (polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Braided polyester (Dagrofil without coating versus the silicone coating of Premisut); verify 1/2 angle, 17 mm trocar point and USP gauge before substituting. |
There is no equivalence table validated by the manufacturer cross-referencing the Premisut reference with other brands; cross-references with Ethicon and B. Braun are functional category comparisons pending official confirmation. Consult the technical department before use in tenders or reference substitution.
5. Selection tips and variants of interest
- Restricted surgical fields and dense tissues: the 17 mm trocar point (TAPERCUT) offers controlled penetration with minimal aggression; if greater needle travel is required, consider the 26 mm variants (AMP853HRT2620-2) or 36 mm (AMP853HRT3620), both in 2/0 gauge.
- Ophthalmology and neurosurgery: the USP 2/0 gauge with double needle is ideal for continuous sutures and ligatures in delicate tissues; the white colour facilitates use in fields where minimal visual interference with tissue is desired.
- Colour preference: if the protocol prefers high-visibility green thread, reference AMP853HRT1720-2 is the natural variant of this same configuration.
- High consumption: for centralised purchasing, consider the multipack presentation of 4 x 90 cm (AMP853HRT1720.4-2) and the variant with reinforcement pledget (AMP853HRT1720.4PL6-2); take into account minimum order conditions.
- Before switching brands: always check needle angle (1/2), size (17 mm), point type (trocar/TAPERCUT), double needle configuration, USP/EP gauge, exact thread material and coating in the alternative manufacturer’s technical data sheet.
- Storage: product sterile by ethylene oxide with a 5-year shelf life; respect storage conditions and the expiry date on the packaging.