Description
1. Introduction
The polyester suture Premisut Prime with double ½ circle needle, cylindrical body and 17 mm trocar point (TAPERCUT) is the reference solution for surgical departments seeking a high-performance non-absorbable thread with smooth handling and predictable tissue behaviour. This configuration incorporates a reinforcement pledget of 6 x 3 x 1.5 mm that increases the support surface of the stitch, particularly useful in soft tissues under tension, friable or prone to tearing.
The multipack of 10 x 75 cm with 5 green and 5 white threads allows standardisation in the surgical block for approximation and ligation procedures, as well as in demanding specialties such as ophthalmology and neurosurgery. It is supplied in a box of 12 units sterilised by ethylene oxide, ready to use and designed for centralised purchasing by the operating theatre department.
2. Technical explanation
The thread is composed of fine polyethylene terephthalate (polyester) fibres braided into a compact multifilament structure and coated with silicone (polyester-polyethylene). This coating improves sliding through tissue, facilitates knot advancement, prevents the sawing or grooving effect and reduces tissue trauma.
Being non-absorbable, it does not degrade by the enzymatic action of the body: it maintains its tensile strength permanently, providing wound support for more than three months while gradual encapsulation by fibrous connective tissue occurs. The ½ circle needle allows suturing in wide or restricted surgical fields with controlled rotational movements, while the trocar point (TAPERCUT) combines the penetration of a cutting needle with the minimal aggression of a round needle: it passes through dense or fibrous tissues without tearing, reducing bleeding and tissue injury. The double needle (2xHRT17) configuration allows continuous sutures with two hemi-arcs without repositioning the needle in the needle holder, optimising surgical time. The pledget acts as a cushion between the suture and the tissue surface, distributing traction forces and preventing the thread from cutting the tissue at tension points.
3. Technical Specifications
| Characteristic | Specification |
| Thread material | Polyester (polyethylene terephthalate) multifilament braided coated with silicone (polyester-polyethylene) |
| Suture type | Non-absorbable, synthetic multifilament, coated, non-channelling |
| Gauge | USP 2/0 (metric size EP 3); approximate diameter 0.35 – 0.399 mm |
| Thread length | 75 cm per thread; multipack 10 x 75 cm (5 green threads + 5 white threads) |
| Reinforcement pledget | 6 x 3 x 1.5 mm |
| Needle shape | 1/2 circle |
| Tip type | Cylindrical body with trocar point (TAPERCUT) |
| Needle configuration | Double needle 2xHRT17, Premilloy stainless steel |
| Needle size | 17 mm |
| Thread colour | Green (D&C Green No. 6) and white (undyed): 5 + 5 |
| Behaviour | No absorption; gradual encapsulation; tissue support exceeding 3 months |
| Tensile strength | High and permanent; exceeds USP and EP requirements |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Commercial presentation | Box of 12 units |
| Shelf life | 5 years |
| Regulatory standard | Conforms to Regulation (EU) 2017/745 (MDR) |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Reference Cahnos | AMP882HRT1720.10PL6-2 |
| Factory reference | P882HRT1720.10PL6-2 (Premisut Prime line) |
4. Equivalences and Cross-References
The SKU Cahnos AMP882HRT1720.10PL6-2 corresponds to the official factory reference P882HRT1720.10PL6-2 of the Premisut Prime line (distributor’s own coding on the same technical configuration), thus constituting an exact reference equivalence. Within the same family, the following variants are found:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut Prime) | Polyester 1/2 trocar 2xHRT17, 2/0, 10×75 (5+5), with pledget 6x3x1.5 mm | AMP882HRT1720.10PL6-2 (factory ref. P882HRT1720.10PL6-2) | Reference analysed / direct equivalent | Configuration covered by this data sheet; double needle 17 mm, gauge 2/0 and pledget of 6x3x1.5 mm. |
| Cahnos (Premisut Prime) | Polyester 1/2 trocar 2xHRT17, 2/0, 10×75 (5+5), with pledget 3x3x1.5 mm | AMP882HRT1720.10PL3-2 | Family equivalence | Same needle, gauge, length and multipack; pledget with smaller surface (3x3x1.5 mm). Not interchangeable 1:1 if the protocol requires 6×3. |
| Cahnos (Premisut Prime) | Polyester 1/2 trocar 2xHRT17, 2/0, 10×75 (5+5), without pledget | AMP882HRT1720.10-2 | Family equivalence | Same needle, gauge and multipack; without reinforcement pledget. Not interchangeable 1:1 if stitch reinforcement is required. |
| Ethicon (Johnson & Johnson MedTech) | Ethibond Excel (polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Coated non-absorbable polyester multifilament with similar indications; verify 1/2 tapercut geometry of 17 mm, double needle, pledget and USP/EP gauge. |
| B. Braun | Premicron (polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Braided coated polyester; verify 1/2 angle, 17 mm trocar point, presence of pledget and USP gauge before substituting. Pending official confirmation. |
Note: there is no equivalence table validated by the manufacturer that cross-references the Premisut Prime reference with other brands; the cross-references with Ethicon and B. Braun are functional category comparisons pending official confirmation. Consult the technical department before use in tendering or substitution of references.
5. Selection tips and variants of interest
- Tissues under tension or friable: the 6 x 3 x 1.5 mm pledget distributes the stitch load and prevents tissue cutting; if you prefer a smaller support surface, consider the variant with 3x3x1.5 mm pledget (AMP882HRT1720.10PL3-2) or the version without pledget (AMP882HRT1720.10-2).
- Restricted surgical fields: the 17 mm trocar point (TAPERCUT) offers controlled penetration with minimal aggression; if a longer needle path is required, consider the 26 mm variant with pledget (AMP882HRT2620.10PL6-2) from this same family.
- Single-colour protocols: if your centre standardises green or white thread, references AMP853HRT1720-2 (green, 90 cm) and AMP873HRT1720-2 (white, 90 cm) maintain the same 2xHRT17 needle and 2/0 gauge.
- High consumption: for centralised purchasing, consider the 4 x 90 cm multipack with pledget (AMP853HRT1720.4PL6-2) and adjacent gauges (USP 3/0, ref. AMP882HR1730.10-2) for different tissue planes.
- Before changing brand: always check needle angle (1/2), size (17 mm), point type (trocar/TAPERCUT), double needle configuration, USP/EP gauge, exact thread material, coating and presence of pledget in the alternative manufacturer’s technical data sheet.
- Storage: sterile product by ethylene oxide with a shelf life of 5 years, single-use and not re-sterilisable; respect storage conditions and the expiry date of the packaging.





Reviews