Description
1. Introduction
The polyester suture Premisut Prime in 1/2 circle configuration, cylindrical body and 17 mm trocar point (TAPERCUT) is the reference solution for surgical departments seeking a high-performance non-absorbable thread, with smooth handling and predictable tissue behaviour. Presented in USP 2/0 (EP 3) gauge and multipack of 10 x 75 cm with 5 green and 5 white threads, it allows operating theatres to standardise criteria in soft tissue approximation and ligation procedures, as well as in demanding specialties such as ophthalmology and neurosurgery.
It is supplied in a box of 12 units sterilised by ethylene oxide, ready to use at the time of the procedure and designed for centralised purchasing by the surgical block. Request a no-obligation quote for hospital volumes.
2. Technical explanation
The thread is composed of fine polyethylene terephthalate (polyester) fibres braided into a compact multifilament structure and coated with silicone, which improves sliding through tissue, facilitates knot descent and reduces tissue trauma. Being non-absorbable, it does not degrade by the body’s enzymatic action: it maintains its tensile strength over a prolonged period, providing wound support for more than three months while gradual encapsulation by fibrous connective tissue occurs.
The 1/2 circle needle allows suturing in wide spaces with controlled rotational movements, while the trocar point (TAPERCUT) combines the penetration of a cutting needle with the minimal aggression of a round needle: it passes through dense or fibrous tissues without tearing, reducing bleeding and tissue injury. The double needle configuration (2xHRT17) allows continuous sutures to be performed with two half-arcs without repositioning the needle in the needle holder, optimising surgical time in reduced fields.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Thread material | Braided multifilament polyester (polyethylene terephthalate) coated with silicone |
| Suture type | Non-absorbable, synthetic coated multifilament |
| Gauge | USP 2/0 (EP 3) |
| Thread length | 75 cm per thread; multipack 10 x 75 cm (5 green threads + 5 white threads) |
| Needle shape | 1/2 circle |
| Tip type | Cylindrical body with trocar point (TAPERCUT), non-grooved needle |
| Needle configuration | Double needle 2xHRT17, Premilloy stainless steel |
| Needle size | 17 mm |
| Thread colour | Green (D&C Green No. 6) and white (undyed): 5 + 5 |
| Behaviour | No absorption; gradual encapsulation; tissue support exceeding 3 months |
| Tensile strength | Permanent; exceeds USP and EP requirements |
| Sterilisation | Ethylene oxide (EO) |
| Commercial presentation | Box of 12 units; minimum order of 10 boxes |
| Shelf life | 5 years |
| Regulatory standard | Conforms to Regulation (EU) 2017/745 (MDR) |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Reference Cahnos | AMP882HRT1720.10-2 |
| Factory reference | P882HRT1720.10-2 (line Premisut / Atlas Medical) |
4. Equivalences and Cross-References
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Atlas Medical (Premisut Prime) | Polyester 1/2 trocar 2xHRT17, 2/0, 10×75 (5+5) | P882HRT1720.10-2 (factory ref.) / AMP882HRT1720.10-2 (SKU Cahnos) | Identical (same official reference) | The Cahnos SKU corresponds to the same factory reference with its own distributor coding; same needle, thread, gauge and 5+5 multipack. |
| Atlas Medical (Premisut Prime) | Polyester 1/2 trocar 2xHRT17, 2/0, 10×75 (5+5), with pledget 3x3x1.5 mm | AMP882HRT1720.10PL3-2 | Family equivalence | Same needle, gauge, length and multipack; incorporates pledget for stitch reinforcement. Not interchangeable 1:1 if pledget is not required. |
| Atlas Medical (Premisut Prime) | Polyester 1/2 trocar 2xHRT17, 2/0, 10×75 (5+5), with pledget 6x3x1.5 mm | AMP882HRT1720.10PL6-2 | Family equivalence | Same needle, gauge, length and multipack; incorporates a larger-surface pledget. Not interchangeable 1:1 if pledget is not required. |
| Atlas Medical (Premisut Prime) | Polyester 1/2 trocar 2xHRT26, 2/0, 10×75 (5+5) | AMP882HRT2620.10-2 | Family equivalence | Same configuration, gauge and multipack; 26 mm needle instead of 17 mm. Not interchangeable 1:1 if the procedure requires 17 mm. |
| Ethicon (Johnson & Johnson MedTech) | Ethibond Excel (polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Non-absorbable coated polyester multifilament with similar indications; verify needle geometry (1/2 tapercut 17 mm), double needle and USP/EP gauge. |
| B. Braun | Premicron (polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Coated braided polyester; verify 1/2 angle, 17 mm needle length, colour and USP gauge. Pending official confirmation. |
Note: there is no equivalence table validated by the manufacturer that cross-references the Premisut Prime AMP882HRT1720.10-2 with other brands; the cross-references with Ethicon and B. Braun are functional category comparisons pending official confirmation. Consult the technical department before use in tenders or reference substitution.
5. Selection tips and variants of interest
- Reduced surgical fields: the 17 mm trocar needle (TAPERCUT) offers controlled penetration with minimal aggression; if the procedure requires greater travel or deeper tissue, consider the 26 mm variant (AMP882HRT2620.10-2).
- Stitch reinforcement: if working with tense or traumatised tissues, the versions with pledget 3x3x1.5 mm (AMP882HRT1720.10PL3-2) and 6x3x1.5 mm (AMP882HRT1720.10PL6-2) increase the thread’s support surface and prevent stitch cutting.
- Single-colour protocols: if your centre standardises green or white suture, you can consult references from the same family with single-colour thread and the same 2xHRT needle and 2/0 gauge.
- Centralised purchasing: for high consumption, consider multipacks from the same family and adjacent gauges (3/0, USP 0) for different tissue planes.
- Before switching brands: always check needle angle (1/2), size (17 mm), point type (trocar/TAPERCUT), double needle configuration, USP/EP gauge, exact thread material and coating in the alternative manufacturer’s technical data sheet.
- Storage: product sterilised by ethylene oxide with a 5-year shelf life; respect storage conditions and the packaging expiry date. Minimum order of 10 boxes for centralised purchasing.





Reviews