Description
1. Introduction
The polyester suture Premisut Prime in a 1/2 circle configuration, cylindrical body and 26 mm trocar point (TAPERCUT) is the reference option for surgical departments seeking a high-performance non-absorbable suture with smooth handling and predictable tissue behaviour. Presented in USP gauge 2/0, white and 90 cm length, it allows professionals to standardise criteria in soft tissue approximation and ligation procedures, as well as in demanding specialties such as ophthalmology and neurosurgery. It is supplied in a box of 12 units sterilised by ethylene oxide, ready to use at the time of the procedure and designed for centralised purchasing by the surgical block.
2. Technical explanation
The thread is composed of fine polyethylene terephthalate (polyester) fibres braided into a compact multifilament structure and coated with silicone, which improves passage through tissue, facilitates knot advancement and reduces tissue trauma. Being non-absorbable, it does not degrade by enzymatic action of the body: it maintains its tensile strength over a prolonged period, providing wound support for more than three months while gradual encapsulation by fibrous connective tissue occurs.
The 1/2 circle needle allows suturing in wide spaces with controlled rotational movements, while the trocar point (TAPERCUT) combines the penetration of a cutting needle with the minimal aggression of a round needle: it passes through dense or fibrous tissues without tearing, reducing bleeding and tissue damage. The double needle configuration (2xHRT26) allows continuous sutures to be performed with two half-arcs without repositioning the needle in the needle holder, optimising surgical time.
3. Technical Specifications
| Material | Braided multifilament polyester (polyethylene terephthalate) |
| Coating | Silicone (polyester – polyethylene) |
| Suture type | Non-absorbable, synthetic coated multifilament |
| Gauge | USP 2/0 (EP 3) |
| Thread length | 90 cm |
| Needle shape | 1/2 circle |
| Tip type | Cylindrical body with trocar point (TAPERCUT) |
| Needle configuration and size | Double needle 2xHRT26, 26 mm |
| Colour | White |
| Behaviour | No absorption; gradual encapsulation; tissue support exceeding 3 months |
| Tensile strength | Permanent; exceeds USP and EP requirements |
| Sterilisation | Ethylene oxide (EO) |
| Presentation | Box of 12 units |
| Regulatory standard | Conforms to Regulation (EU) 2017/745 (MDR) |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Reference | AMP873HRT2620-2 (Premisut Prime line) |
4. Equivalences and Cross-References
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut (Atlas Medical) | Polyester 1/2 trocar 2xHRT26, 2/0 white, 90 cm (standard range) | AM873HRT2620-2 | Family equivalence | Same geometry, needle, gauge, colour and length; standard range without Prime finish. Not interchangeable 1:1 without prior validation. |
| Premisut Prime | Polyester 1/2 trocar 2xHRT26, 2/0 green, 90 cm | AMP853HRT2620-2 | Family equivalence | Same configuration, gauge and length; only the thread colour changes (green). Not interchangeable 1:1 in single-colour protocols. |
| Premisut Prime | Polyester 1/2 trocar 2xHRT26, 3/0 green, 90 cm | AMP853HRT2630-2 | Family equivalence | Same needle and geometry; finer gauge 3/0. Not interchangeable 1:1. |
| Premisut Prime | Polyester 1/2 trocar 2xHRT26, USP 0 green, 90 cm | AMP853HRT2610-2 | Family equivalence | Same needle and geometry; larger gauge USP 0. Not interchangeable 1:1. |
| Premisut Prime | Polyester 1/2 trocar 2xHRT36, 2/0 green, 90 cm | AMP853HRT3620 | Family equivalence | Same configuration, gauge and length; 36 mm needle instead of 26 mm. Not interchangeable 1:1. |
| Premisut Prime | Polyester 1/2 trocar 2xHRT26, 2/0 green, 4×90 cm | AMP853HRT2620.4-2 | Family equivalence | Same needle and gauge; multipack of 4 threads of 90 cm. Not interchangeable 1:1 in presentation. |
| Premisut Prime | Polyester 1/2 trocar 2xHRT26, 2/0 green, 4×90 cm with PTFE pledget | AMP853HRT2620.4PL6-2 | Family equivalence | Same configuration with PTFE pledget 6x3x1.5 mm for stitch reinforcement. Not interchangeable 1:1. |
| Ethicon (Johnson & Johnson MedTech) | Ethibond Excel (polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Non-absorbable coated polyester multifilament with similar indications; verify needle geometry (1/2 tapercut 26 mm), double needle configuration and USP/EP gauge before substituting. |
| B. Braun | Premicron / Dagrofil (polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Coated braided polyester; verify 1/2 angle, needle length of 26 mm, colour and USP gauge. Pending official confirmation. |
Important note: there is no equivalence table validated by the manufacturer that cross-references the Premisut Prime AMP873HRT2620-2 with other brands; the cross-references with Ethicon and B. Braun are functional category comparisons pending official confirmation. Consult the technical department before use in tenders or substitution of references.
5. Selection tips and variants of interest
Dense or fibrous tissues: the 26 mm trocar point (TAPERCUT) offers controlled penetration with minimal aggression. For wider surgical fields, consider the 36 mm needle variant (AMP853HRT3620).
Single-colour protocols: if your centre standardises white suture, this reference AMP873HRT2620-2 maintains the 2xHRT26 needle, 2/0 gauge and 90 cm thread; if green thread with identical performance is preferred, the AMP853HRT2620-2 variant is the natural alternative.
Ophthalmology and neurosurgery: the USP 2/0 gauge with double needle is ideal for continuous sutures and ligatures in delicate tissues; for finer gauges, the 3/0 variant (AMP853HRT2630-2) is the alternative within the same family.
Centralised purchasing: for high consumption, consider the multipack presentations of 4 x 90 cm (AMP853HRT2620.4-2) and the variants with PTFE pledget (AMP853HRT2620.4PL6-2) for stitch reinforcement in tissues under tension.
Before substituting brand: always check needle angle (1/2), size (26 mm), point type (trocar/TAPERCUT), double needle configuration, USP/EP gauge, exact thread material and coating in the alternative manufacturer’s technical data sheet.
Storage: sterile product by ethylene oxide; respect storage conditions and the expiry date of the packaging.