Description
1. Introduction
The polyester suture Premisut in a ½ circle configuration, cylindrical body and trocar point (tapercut) of 26 mm is the reference option for surgical departments seeking a high-performance non-absorbable thread with smooth handling and predictable tissue behaviour. Presented in USP 2/0 gauge, white colour and 90 cm length, it allows professionals to standardise criteria in soft tissue approximation and ligation procedures, as well as in demanding specialties such as ophthalmology and neurosurgery. It is supplied in a box of 12 units sterilised by ethylene oxide, ready for use at the time of the procedure.
2. Technical explanation
The thread is composed of fine polyethylene terephthalate (polyester) fibres braided into a compact multifilament structure and coated with silicone, which improves passage through tissue, facilitates knot advancement and reduces tissue trauma. Being non-absorbable, it does not lose strength through the enzymatic action of the body: it maintains its tensile strength over a prolonged period, providing wound support for more than three months while gradual encapsulation by fibrous connective tissue occurs.
The ½ circle needle allows suturing with controlled rotational movements, while the trocar point (tapercut) combines the penetration of a cutting needle with the minimal aggression of a round needle: it passes through dense or fibrous tissues without tearing, reducing bleeding and tissue damage. The double needle configuration (2xHRT26) allows continuous sutures to be performed with two half-arcs without repositioning the needle in the needle holder, optimising surgical time. The white colour facilitates identification in protocols that do not use dyed thread.
3. Technical Specifications
3.1. General characteristics
| Characteristic | Specification |
| Material | Braided multifilament polyester (polyethylene terephthalate) |
| Coating | Silicone (polyester – polyethylene) |
| Suture type | Non-absorbable, synthetic coated multifilament |
| Gauge | USP 2/0 (metric 3) |
| Thread length | 90 cm |
| Needle shape | 1/2 circle |
| Tip type | Cylindrical body with trocar point (tapercut) |
| Needle size | 2xHRT26 mm (double needle) |
| Colour | White |
| Behaviour | No absorption; gradual encapsulation; tissue support exceeding 3 months |
| Sterilisation | Ethylene oxide (EO) |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Factory reference | 873HRT2620-2 |
| Reference Cahnos (SKU) | AM873HRT2620-2 |
3.2. Gauge equivalence (USP/EP table)
| USP size | Metric size | Approximate thread diameter |
| 2/0 | 3 | 0.35 – 0.399 mm (USP/EP standard) |
4. Equivalences and Cross-References
Non-absorbable braided polyester suture is a well-established category in the market. The located references are indicated below with their level of equivalence; remember that only a change in thread colour maintains the condition of direct equivalent.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Atlas Medical (Premisut) | Polyester 1/2 trocar 2xHRT26, 2/0 green, 90 cm | AM853HRT2620-2 | Direct equivalent | Same 2xHRT26 needle, same gauge and length; only the thread colour changes (green instead of white). |
| Atlas Medical (Premisut Prime) | Polyester 1/2 trocar 2xHRT26, 2/0 green, 90 cm | AMP853HRT2620-2 | Family equivalence | Same geometry, gauge and length; Prime quality with superior handling. Not interchangeable 1:1 without prior validation. |
| Atlas Medical (Premisut) | Polyester 1/2 trocar 2xHRT26, 3/0 green, 90 cm | AM853HRT2630-2 | Family equivalence | Same needle and length; finer USP gauge 3/0. Not interchangeable 1:1. |
| Atlas Medical (Premisut Prime) | Polyester 1/2 trocar 2xHRT36, 2/0 green, 90 cm | AMP853HRT3620 | Family equivalence | Same gauge and configuration; 36 mm needle instead of 26 mm. Not interchangeable 1:1. |
| Atlas Medical (Premisut Prime) | Polyester 1/2 trocar 2xHRT26, 2/0 green, 4×90 cm | AMP853HRT2620.4-2 | Family equivalence | Same needle and gauge; multipack of 4 threads of 90 cm. Not interchangeable 1:1. |
| B. Braun | Dagrofil (braided polyester), 2/0 (EP 3), 90 cm, double needle HRT26, green | C0849383 | Comparable by category, not interchangeable 1:1 | Same EP 3 gauge, 90 cm thread and double needle; Dagrofil is supplied uncoated compared to the silicone coating of Premisut. Verify availability and local regulations. |
| Ethicon (Johnson & Johnson MedTech) | Ethibond Excel / Mersilene (braided polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Non-absorbable polyester multifilament with similar indications; verify needle geometry, size, gauge and coating in the official technical data sheet before substituting. |
Important note: there is no equivalence table validated by the manufacturer that cross-references the Premisut reference with other brands; the cross-references with B. Braun and Ethicon are functional category comparisons pending official confirmation. Consult the technical department of Cahnos before use in tenders or substitution of references.
5. Selection tips and variants of interest
The 26 mm trocar point (tapercut) offers controlled penetration with minimal aggression in dense or fibrous tissues; for wider surgical fields, consider the 36 mm needle variant (AMP853HRT3620). If your centre standardises green suture with identical performance, the reference AM853HRT2620-2 maintains needle, gauge and length changing only the thread colour.
For premium handling, the Prime version (AMP853HRT2620-2) provides superior handling and more consistent knot advancement. In ophthalmology and neurosurgery with finer gauges, the 3/0 variant (AM853HRT2630-2) is the natural alternative within the same family. For high consumption, consider the multipacks of 4 x 90 cm (AMP853HRT2620.4-2) and take into account the minimum order of 30 boxes.
Before substituting brands, always check the needle angle (1/2), the size (26 mm), the point type (trocar/tapercut), the double needle configuration, the USP/EP gauge, the exact thread material and the coating in the alternative manufacturer’s technical data sheet. Storage: sterile product by ethylene oxide, single-use and non-reesterilizable; respect the storage conditions and the expiry date of the packaging.





Reviews