Description
1. Introduction
The Premisut Prime polyester suture with double ½ circle needle, cylindrical body and 26 mm trocar point (TAPERCUT) is the reference solution for surgical departments seeking a high-performance non-absorbable thread with smooth handling and predictable tissue behaviour. This configuration incorporates a 6 x 3 x 1.5 mm reinforcement pledget that increases the bearing surface of the stitch, particularly useful in soft tissues under tension, friable tissues or those prone to tearing.
The 10 x 75 cm multipack with 5 green and 5 white threads allows criteria to be unified in the surgical block for approximation and ligation procedures, as well as in demanding specialties such as ophthalmology and neurosurgery. It is supplied in a box of 12 units sterilised by ethylene oxide, ready to use and designed for centralised purchasing by the operating theatre department.
2. Technical explanation
The thread is composed of fine polyethylene terephthalate (polyester) fibres braided into a compact multifilament structure and coated with silicone (polyester-polyethylene). This coating improves passage through tissue, facilitates knot seating, prevents the sawing or channelling effect and reduces tissue trauma.
As it is non-absorbable, it is not degraded by the body’s enzymatic action: it permanently maintains its tensile strength, providing wound support for more than three months while gradual encapsulation by fibrous connective tissue takes place. The ½ circle needle allows suturing in wide or restricted surgical fields with controlled rotational movements, while the trocar point (TAPERCUT) combines the penetration of a cutting needle with the minimal aggression of a round needle: it passes through dense or fibrous tissues without tearing, reducing bleeding and tissue injury. The double-needle configuration (2xHRT26) allows continuous sutures to be performed with two half-arcs without repositioning the needle in the needle holder, optimising surgical time. The pledget acts as a cushion between the suture and the tissue surface, distributing traction forces and preventing the thread from cutting the tissue at tension points.
3. Technical Specifications
| Characteristic | Specification |
| Thread material | Braided multifilament polyester (polyethylene terephthalate) coated with silicone |
| Suture type | Non-absorbable, synthetic multifilament, coated, non-channelling |
| Gauge | USP 2/0 (metric size EP 3); approximate diameter 0.35 – 0.399 mm |
| Thread length | 75 cm per thread; multipack 10 x 75 cm (5 green threads + 5 white threads) |
| Reinforcement pledget | 6 x 3 x 1.5 mm |
| Needle shape | 1/2 circle |
| Tip type | Cylindrical body with trocar point (TAPERCUT) |
| Needle configuration | Double needle 2xHRT26, Premilloy stainless steel |
| Needle size | 26 mm |
| Thread colour | Green (D&C Green No. 6) and white (undyed): 5 + 5 |
| Behaviour | No absorption; gradual encapsulation; tissue support exceeding 3 months |
| Tensile strength | High and permanent; exceeds USP and EP requirements |
| Sterilisation | Ethylene oxide (EO), sterile, single-use, not re-sterilisable |
| Commercial presentation | Box of 12 units |
| Shelf life | 5 years |
| Regulatory standard | Conforms to Regulation (EU) 2017/745 (MDR) |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Reference Cahnos | AMP882HRT2620.10PL6-2 |
| Factory reference | P882HRT2620.10PL6-2 (Premisut Prime line) |
4. Equivalences and Cross-References
The Cahnos SKU AMP882HRT2620.10PL6-2 corresponds to the official factory reference P882HRT2620.10PL6-2 from the Premisut Prime line (distributor’s own coding on the same technical configuration), and therefore constitutes an exact reference equivalence. For other brands on the market, the following cross-references are functional category comparisons pending official confirmation:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | Ethibond Excel (polyester) | Consult official catalogue | Comparable by category (not interchangeable 1:1) | Non-absorbable coated polyester multifilament with similar indications; verify needle geometry (1/2 tapercut 26 mm), double-needle configuration, pledget and USP/EP gauge before substituting. |
| B. Braun | Premicron (polyester) | Consult official catalogue | Not verified | Braided coated polyester; verify 1/2 angle, 26 mm trocar point, presence of pledget and USP gauge. Pending official confirmation. |
| Medtronic (Covidien) | Ti-Cron (coated polyester) | Consult official catalogue | Not verified | Same base material with similar coating; confirm 2xHRT26 needle, pledget and presentation in the official catalogue. |
There is no equivalence table validated by the manufacturer cross-referencing the Premisut Prime reference with other brands; the cross-references indicated are functional category comparisons pending official confirmation. Consult the technical department before use in tendering or reference substitution.
5. Selection tips and variants of interest
- Stitch reinforcement: if you work with tissues under tension or friable tissues, this version with 6x3x1.5 mm pledget distributes the load and prevents the stitch from cutting; if you prefer a smaller bearing surface, consider the variant with 3x3x1.5 mm pledget (AMP882HRT1720.10PL3-2) or without pledget (AMP882HRT2620.10-2).
- Restricted surgical fields: the 26 mm trocar point (TAPERCUT) offers controlled penetration; if a shorter needle travel is required, the 17 mm variant with pledget (AMP882HRT1720.10PL6-2) is the natural alternative from the same family.
- Single-colour protocols: if your centre standardises green or white thread, references AMP853HRT2620-2 (green, 90 cm) and AMP873HRT2620-2 (white, 90 cm) maintain the same 2xHRT26 needle and 2/0 gauge.
- Centralised purchasing: for high consumption, consider the 4 x 90 cm multipack (AMP853HRT2620.4-2) and the PTFE pledget variant (AMP853HRT2620.4PL6-2), as well as adjacent gauges 3/0 (AMP853HRT2630-2) and USP 0 (AMP853HRT2610-2) for different tissue planes.
- Before changing brand: always check needle angle (1/2), size (26 mm), point type (trocar/TAPERCUT), double-needle configuration, USP/EP gauge, exact thread material, coating and presence of pledget in the alternative manufacturer’s technical data sheet.
- Storage: sterile product by ethylene oxide with a 5-year shelf life, single-use and not re-sterilisable; respect the storage conditions and the expiry date of the packaging.





Reviews