Description
1. Product Presentation
The polyester suture Premisut Prime with ½ circle HR26 needle is the reference choice for the professional seeking a non-absorbable thread with a soft feel, high tensile strength and minimal tissue drag. Its cylindrical-bodied needle with a 26 mm conical point (taperpoint) passes through tissue by separating the fibres without cutting them, which is especially indicated in delicate planes such as ophthalmology and neurosurgery, as well as in the approximation of soft tissues and ligatures. It is supplied sterile, ready for use, in a box of 12 units, with full traceability for hospital purchasing and B2B tenders.
2. Technical explanation
It is a braided multifilament polyester suture (polyethylene terephthalate, PET) coated with silicone. The silicone coating provides a smooth outer surface that slides gently through tissue, reduces the sawing effect when tying knots and improves handling and knot security. Being non-absorbable, it does not lose mass or strength through hydrolysis: gradual fibrous encapsulation occurs and the wound retains mechanical support beyond three months. The ½ circle conical-point needle (HR26, 26 mm) facilitates atraumatic and controlled passes, with excellent tensile strength in confined spaces. Sterilisation by ethylene oxide (EtO), for single use and without the possibility of re-sterilisation.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Brand / line | Premisut – Prime (Premister Prime series) |
| Thread material | Braided multifilament polyester (polyethylene terephthalate, PET) coated with silicone |
| Suture type | Non-absorbable, synthetic coated multifilament |
| Absorption | No absorption; gradual encapsulation; wound support exceeding 3 months |
| Gauge | USP 3/0 (metric size 2) |
| Thread length | 75 cm |
| Needle shape | ½ circle (1/2 circular) |
| Needle body | Cylindrical |
| Needle tip | Conical – taperpoint (atraumatic) |
| Needle size | 26 mm (HR26 Prime) |
| Thread colour | Green (fluted; also available in white depending on variant) |
| Sterilisation | Ethylene oxide (EtO), single-use, not re-sterilisable |
| Indications | Soft tissue approximation, ligatures, ophthalmology, neurosurgery |
| Presentation | Box of 12 units |
| Regulatory standard | Exceeds USP and EP requirements; compliant with Regulation (EU) 2017/745 (MDR) |
| Reference Cahnos (SKU) | AMP852HR2630 |
3.2. Gauge equivalence (USP/EP table)
| USP size | Metric size | Approximate thread diameter |
|---|---|---|
| 3/0 | 2 | 0.20 – 0.249 mm (USP/EP standard) |
4. Equivalences and Cross-References
There is no official equivalence table validated by the manufacturer for this exact configuration (½ circle 26 mm conical-point needle + gauge 3/0 + 75 cm + green). The cross-references indicated below are category-level comparisons and should not be considered interchangeable 1:1 without prior technical verification.
| Manufacturer / Brand | Family / Model | Indicative code | Equivalence level | Technical differences |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | ETHIBOND EXCEL™ (braided polyester, green) | W6832 (USP 3/0, 75 cm, SH needle ½ circle conical point 26 mm) | Comparable at category level | Polybutylate coating (not silicone); same needle size (26 mm) but verify actual radius, point and gauge before substituting |
| Medtronic (Covidien) | Surgidac™ / Ti-Cron™ (non-absorbable braided polyester) | Consult official catalogue for gauge and needle | Comparable at category level | Same base material (polyethylene terephthalate) and indications including ophthalmic and neural tissue; confirm coating and needle geometry by reference |
| B. Braun | PremiCron (silicone-coated braided polyester terephthalate) | Consult range with HR needle (Easyslide line) | Comparable at category level | Same type of thread and silicone finish; locate the combination gauge 3/0 × 75 cm × 26 mm needle in the local price list and validate the exact code with the distributor |
| Cahnos – same family Premisut (HR26) | Premisut Prime polyester, same HR26 needle | AMP852HR2640 (HR26, 4/0) | Family equivalence | Same needle, thread and colour; the gauge changes (4/0 versus 3/0). Choose gauge according to clinical need |
| Cahnos – Premisut other geometries | HR30 and double needle | AMP852HR3030 (HR30, 3/0) / AMP852HR2020-2 (2xHR20, 2/0) | Similar by category | Different radius or needle size; not interchangeable 1:1 with single HR26 needle |
Pending confirmation: for use in tenders or substitution of another manufacturer’s reference, consult the technical department before formalising the change.
5. Selection tips and variants of interest
- If you need the same HR26 needle with a finer gauge, request the USP 4/0 variant (AMP852HR2640), both in green and 75 cm.
- For the same gauge 3/0 with a larger radius needle, consider the HR30 variant (AMP852HR3030); for continuous suture with double needle in ½ circle radius, the family offers AMP852HR2020-2 (2xHR20, USP 2/0, green).
- For tissues of medium or dense consistency, the same family offers a trocar-point (tapercut) needle HRT40 in gauge 3/0 (AMP852HRT4030H).
- Always verify the compatibility of the needle (½ radius, conical point, 26 mm) with the needle holder and the suture technique (interrupted or continuous) of your department.
- As it is a non-absorbable thread, it does not require replacement due to loss of strength; its removal, if required, is surgical. Confirm your centre’s protocol.
- Storage: keep below 30 °C, away from moisture and direct sunlight; check the integrity of the packaging before each procedure and do not re-sterilise or reuse.





Reviews