Description
1. Introduction
The polyester suture Premisut Prime in a ½ circle configuration with double needle and 20 mm taper point is the choice of surgical departments seeking a high-performance non-absorbable thread with smooth handling and predictable tissue behaviour. Supplied in USP 2/0 gauge, green colour and 75 cm of thread, it allows standardisation in soft tissue approximation and ligation procedures, as well as in demanding specialties such as ophthalmology and neurosurgery.
Prime quality guarantees a regular thread surface, smooth passage through tissue, consistent knot seating and excellent knot retention. It is supplied in a box of 12 units sterilised by ethylene oxide, ready to use at the time of the procedure and designed for centralised purchasing by the surgical block.
2. Technical explanation
The thread is composed of fine polyethylene terephthalate (polyester, PET) fibres braided into a compact multifilament structure and coated with silicone (polyester – polyethylene). This coating improves passage through tissue, facilitates knot seating, prevents the sawing or grooving effect and reduces tissue trauma, without compromising tensile strength.
Being non-absorbable, it is not degraded by the body’s enzymatic action: it maintains its tensile strength over a prolonged period, supporting the wound for more than three months while gradual encapsulation by fibrous connective tissue occurs. The ½ circle needle allows suturing in wide or restricted surgical fields with controlled rotational movements, while its taper point (Taperpoint) passes through tissue by separating fibres without cutting them, with minimal tissue trauma, making it especially suitable for delicate tissues. The double needle configuration (2xHR20) allows continuous sutures to be placed with two half-circles without repositioning the needle in the needle holder, optimising surgical time.
3. Technical Specifications
3.1. General characteristics
| Characteristic | Specification |
| Brand / line | Premisut Prime (PREMISTER PRIME series) |
| Thread material | Braided multifilament polyester (polyethylene terephthalate, PET) |
| Coating | Silicone (polyester – polyethylene), non-grooved surface |
| Suture type | Non-absorbable, synthetic coated multifilament |
| Gauge | USP 2/0 (metric size EP 3) |
| Thread length | 75 cm |
| Needle shape | 1/2 circle |
| Tip type | Cylindrical body with conical tip (Taperpoint), atraumatic |
| Needle configuration and size | Double needle 2xHR20, 20 mm |
| Number of needles | 2 (double needle) |
| Thread colour | Green (D&C Green No. 6) |
| Behaviour | No absorption; gradual encapsulation; tissue support exceeding 3 months |
| Tensile strength | High and permanent; exceeds USP and EP requirements |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Presentation | Box of 12 units; minimum order 30 boxes |
| Shelf life | 5 years |
| Regulatory standard | Conforms to Regulation (EU) 2017/745 (MDR) |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Reference Cahnos (SKU) | AMP852HR2020-2 |
3.2. Gauge equivalence (USP/EP table)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 2/0 | 3 | 0.35 – 0.399 mm (USP/EP standard) |
4. Equivalences and Cross-References
Non-absorbable braided polyester suture is a well-established category in the market, present in most major manufacturers. The references identified are listed below with their level of equivalence; note that only a change in thread colour, while keeping the needle, gauge and length, maintains the condition of direct equivalent within the same family. For equivalents between brands, the coating, needle geometry and exact diameter differ, so they must always be verified in the official technical data sheet.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut Prime | Polyester 1/2 taper point 2xHR20, 2/0 green, 75 cm | AMP852HR2020-2 | Reference analysed | Product covered by this data sheet; Prime quality with superior needle and finish. Factory code of the pattern P852HR20… pending official confirmation with the manufacturer. |
| Premisut Prime | Polyester 1/2 taper point 2xHR20, 2/0, multipack 10×75 cm (5 green + 5 white) | AMP882HR2020.10-2 | Family equivalence, not interchangeable 1:1 | Same needle 2xHR20 and same USP 2/0 gauge; differs in presentation (dual multipack 5+5) and colour. Not interchangeable 1:1 if the presentation is a protocol requirement. |
| Premisut Prime | Polyester 1/2 taper point 2xHR20, 4/0 green, 75 cm | AMP852HR2040-2 | Family equivalence, not interchangeable 1:1 | Same needle and length; finer USP 4/0 gauge for very delicate tissues. |
| Premisut Prime | Polyester 1/2 taper point 2xHR26, 2/0 green, 90 cm | AMP853HR2620-2 | Family equivalence, not interchangeable 1:1 | Same gauge and double needle configuration; 26 mm needle and 90 cm thread for larger fields. |
| Premisut Prime | Polyester 1/2 trocar tip 2xHRT17, 2/0 green, 90 cm | AMP853HRT1720-2 | Comparable by category, not interchangeable 1:1 | Same material and gauge; changes the point type (trocar instead of taper) and needle size (17 mm). Suitable when denser tissues need to be penetrated. |
| Ethicon (Johnson & Johnson MedTech) | Ethibond Excel / Mersilene (braided polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Non-absorbable polyester multifilament with similar indications; differs in coating (polybutylate vs silicone). Confirm 20 mm taper point, 1/2 circle and actual USP/EP gauge. |
| B. Braun (Aesculap) | PremiCron / Dagrofil (braided polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Same type of braided polyester thread; verify coating, 1/2 HR20 needle geometry and USP/EP gauge in the official technical data sheet before substituting. |
| Medtronic (Covidien) / Teleflex | Surgidac / Ti-Cron / Tevdek II (coated braided polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Same base material; Ti-Cron silicone-coated similar to Premisut. Confirm 2xHR20 needle and presentation in the official catalogue. |
Important note: there is no equivalence table validated by the manufacturer that cross-references this Premisut reference with other brands; the cross-references with Ethicon, B. Braun, Medtronic and Teleflex are functional category comparisons pending official confirmation. Consult the technical department of Cahnos before use in tenders or reference substitution.
5. Selection tips and variants of interest
Delicate tissues and restricted fields: the 20 mm taper point (Taperpoint) offers atraumatic penetration by separating fibres without cutting them, ideal for ophthalmology, neurosurgery, soft tissue approximation and ligations. If the protocol requires denser or fibrous tissues, consider the trocar point (Tapercut) from the same family (AMP853HRT1720-2).
Same needle, alternative gauge: with the 2xHR20 needle, USP 4/0 gauge (AMP852HR2040-2) is available for maximum fineness in microsurgery.
Longer needle travel: for wider surgical fields, the variant with 2xHR26 needle and 90 cm thread (AMP853HR2620-2) maintains USP 2/0 gauge.
Centralised purchasing: the dual multipack 10×75 cm (5 green + 5 white, AMP882HR2020.10-2) unifies consumption of both colours in a single pack; consult minimum order conditions with your Cahnos advisor.
Before substituting brands: always check needle angle (1/2), size (20 mm), point type (taper/Taperpoint), double needle configuration, USP/EP gauge, exact thread material and coating in the alternative manufacturer’s technical data sheet.
Storage: sterile product by ethylene oxide with a shelf life of 5 years, single-use and non-resterilizable; respect storage conditions (below 30 °C, away from humidity and direct sunlight) and the expiry date of the packaging.