Description
1. Introduction
The non-absorbable polyester suture Premisut with a ½ circle conical-point needle of 36 mm (HR36) is the reference solution for general surgery, ophthalmology, neurosurgery and purchasing centres seeking a permanent, high-strength thread with predictable clinical performance. Its braided multifilament structure with silicone coating offers smooth passage through tissue, high tensile strength and an excellent cost-performance ratio, making it a highly competitive option for equipping operating theatres, replenishing stock and tender processes. Professional presentation in a box of 12 units.
2. Technical explanation
The thread is composed of polyester fibres (polyethylene terephthalate) braided into a multifilament and uniformly coated with silicone. This coating reduces friction when passing through tissues, promotes sliding and improves knot security without compromising retention, minimising the sawing effect on tissue. As a non-absorbable suture, it does not lose mass or strength through hydrolysis: gradual fibrous encapsulation occurs, maintaining the mechanical integrity of the wound for more than three months, a critical healing period.
The ½ circle needle with cylindrical body and conical point (taperpoint) of 36 mm separates the fibres without cutting them, achieving atraumatic and controlled passes, which is especially indicated in delicate planes such as ophthalmology and neurosurgery. The ribbed green colour ensures optimal visibility of the thread on the surgical field. Sterilisation by ethylene oxide (EO).
3. Technical Specifications
| Parameter | Specification |
| Thread material | Braided multifilament polyester (polyethylene terephthalate / polyester – polyethylene) |
| Coating | Silicone (optimal sliding and handling) |
| Structure | Braided multifilament, grooved surface |
| Absorption type | Non-absorbable – gradual encapsulation (support for more than 3 months) |
| USP gauge / size | USP 0 (metric 3.5) |
| Thread length | 75 cm |
| Colour | Green (also available in white depending on reference and stock) |
| Needle shape | ½ circle (1/2 circular) |
| Needle body | Cylindrical |
| Needle point type | Conical – taperpoint (atraumatic) |
| Needle size | HR 36 (36 mm) |
| Sterilisation | Ethylene oxide (EO) |
| Wound support | More than three months |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Presentation | Box of 12 units |
| Factory reference | 852HR3610 |
| SKU Cahnos | AM852HR3610 |
4. Equivalences and Cross-References
Non-absorbable braided polyester is one of the most widespread permanent suture families on the market for approximating soft tissues and ligatures. There is no official equivalence table validated by manufacturers for this specific configuration (HR36 ½ circle conical-point needle + USP 0 gauge + 75 cm + green). The references cited below are declared as functional category comparisons, not interchangeable 1:1 without prior verification against the technical data sheet and IFU of each manufacturer.
| Manufacturer / Brand | Family / Model | Indicative code | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | ETHIBOND EXCEL (braided polyester, green) | W series (consult official catalogue for gauge and needle) | Comparable by category, not interchangeable 1:1 | Polybutylate coating (not silicone); needle geometries different from HR36 |
| B. Braun (Aesculap) | PremiCron (braided polyester coated with silicone, green) | C002… series (consult official catalogue for gauge and needle) | Comparable by category, not interchangeable 1:1 | Same material and same silicone coating; confirm needle size and geometry by reference |
| Medtronic (Covidien) | Ti-Cron / Surgidac | Code series D / CD / ED (consult official catalogue) | Comparable by category, not interchangeable 1:1 | Same base material; Ti-Cron with silicone and Surgidac uncoated; confirm code and needle |
| Cahnos – same family Premisut | Premisut Prime polyester, same gauge and conical needle configuration | AMP852HR3010 (HR30, USP 0, green, 75 cm) | Configuration equivalence within the same system | Same thread, gauge, colour and length; needle size changes (30 mm vs 36 mm) |
Important note: there is no equivalence table validated by the manufacturer for this reference. Before using it as a substitute for another brand in tenders or stock replenishment, consult the technical department of Cahnos and verify the technical data sheet and IFU of the corresponding manufacturer.
5. Selection tips and variants of interest
Before placing the order, verify three parameters: USP gauge (this reference is 0), needle size (HR36 = 36 mm) and thread length/colour (75 cm green). USP 0 is suitable for planes with medium-high mechanical demand and ligatures; consider finer gauges (USP 2/0, 3/0, 4/0) for delicate tissues and precision ophthalmic surgery, and USP 1 or 2 for planes under greater tension (e.g. AM852HR4001, HR40 USP 1).
Within the Cahnos catalogue, the HR family in polyester is available with the same taperpoint conical point: AM852HR2620 (HR26, USP 2/0), AMP852HR3030 (HR30 Prime, USP 3/0), AMP852HR3020 (HR30 Prime, USP 2/0) and AMP852HR3010 (HR30 Prime, USP 0). If your purchasing centre prefers a reverse cutting needle, reference AM852DS3610 maintains the same USP 0 gauge, colour and length with a ⅜ circular DS 36 needle. For other thread structures with the identical HR36 needle, the rapid absorbable PGAR version (AM222HR3610) and the absorbable monofilament PGCL version (AM312HR3610) are available. For larger volumes, special gauges or supply agreements, contact the commercial department of Cahnos.





Reviews
There are no reviews yet.