Description
1. Product Presentation
The polyester suture Premisut (PREMISTER PRIME series) is a consolidated reference in non-absorbable surgical closures that require prolonged and reliable tissue support. Its configuration with a ½ circle needle, cylindrical body and conical point (taperpoint) of 40 mm offers clean and atraumatic penetration with minimal tissue damage. It is the appropriate technical choice for surgical services, purchasing centres and B2B tendering platforms seeking proven quality at a competitive cost per volume.
2. Technical Explanation
The thread is made of polyethylene terephthalate (polyester, PET) fibres braided into a compact multifilament structure and coated with silicone. This coating improves sliding through tissue, facilitates knot descent and reduces tissue trauma. Being non-absorbable, it does not degrade by enzymatic action: it maintains its tensile strength and provides wound support for more than three months while gradual encapsulation by fibrous connective tissue occurs.
The HR40 needle, ½ circle with cylindrical body and conical point (taperpoint configuration), is indicated for passing through soft tissues with a clean path and minimal injury, especially in soft tissue approximation, ligatures, ophthalmology and neurosurgery. It is supplied sterile by ethylene oxide (EtO), for single-use and without the possibility of re-sterilisation, complying with the regulations applicable to non-absorbable surgical sutures (European Pharmacopoeia and USP).
3. Technical Specifications
3.1. General characteristics
| Characteristic | Specification |
|---|---|
| Brand / line | Premisut – PREMISTER PRIME series |
| Material | Braided multifilament polyester (polyethylene terephthalate, PET), silicone-coated |
| Suture type | Non-absorbable, synthetic coated multifilament |
| Needle shape | ½ circle |
| Needle body / tip | Cylindrical body, conical tip (taperpoint) |
| Needle size | HR 40 (40 mm) |
| Gauge | USP 2 (metric size 5) |
| Approximate thread diameter | 0.50 – 0.599 mm (USP/EP standard) |
| Thread length | 75 cm |
| Colour / finish | Green, grooved |
| Tissue behaviour | No absorption; gradual encapsulation; wound support for more than 3 months |
| Sterilisation | Ethylene oxide (EtO) |
| Use | Single-use, not re-sterilisable |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Manufacturer reference | 852HR4002 |
| Reference Cahnos (SKU) | AM852HR4002 |
3.2. Gauge equivalence (USP/EP standard)
| USP size | Metric size | Approximate thread diameter |
|---|---|---|
| 2 | 5 | 0.50 – 0.599 mm |
4. Equivalences and Cross-References
The non-absorbable braided polyester suture in USP size 2 with 75 cm green thread is a common presentation in general, cardiovascular and specialised surgery. The references found in public sources and their level of equivalence are indicated below:
| Manufacturer / Brand | Family / Model | Reference code | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| B. Braun | PremiCron – silicone-coated braided polyester terephthalate (Easyslide) | C0026394 (PremiCron 2, 75 cm, HRT37) | Comparable by category, not interchangeable 1:1 | Code verified in official B. Braun catalogue: same material (siliconised braided polyester), USP size 2, 75 cm green thread, but with HRT37 trocar point needle (37 mm) compared to the conical HR40 needle of 40 mm of this reference. Verify needle geometry before replacing. |
| Ethicon (Johnson & Johnson MedTech) | MERSILENE – braided polyester | No verified code for USP 2 × 75 cm with 40 mm conical needle | Not verified | The MERSILENE family offers green non-absorbable braided polyester with conical point needle (SH) in sizes 2/0 and 1 (e.g. R833H, EH7526H, all with 26 mm needle); the combination USP 2 × 75 cm with 40 mm conical needle has not been found in public sources. Specific code pending confirmation with the manufacturer or authorised distributor. |
| Ethicon (Johnson & Johnson MedTech) | ETHIBOND EXCEL – coated braided polyester | MX69G (USP 2, V-37 needle of 40 mm, thread 4×30 cm) | Comparable by category, not interchangeable 1:1 | Same material and USP size 2 and 40 mm needle, but with trocar point (V-37, tapercut) and presentation of 4×30 cm (120 cm) compared to the conical HR40 point and the 75 cm thread of this reference. Verify tender specifications and geometry before replacing. |
| GIMA / TAGUM | Coated non-absorbable braided polyester | No publicly verified code | Not verified | Manufacturers with non-absorbable braided polyester lines of similar characteristics; specific code pending confirmation with the manufacturer or authorised distributor. |
Important note: there is no official equivalence table validated by the manufacturer for the Premisut line compared to other brands. The cited references are offered as functional category comparisons verified in public sources and not as direct 1:1 equivalents. Before using them in a tender or stock replacement, consult our technical department to validate needle geometry, size and tender regulations.
5. Selection tips and variants of interest
The ½ circle needle with cylindrical body and 40 mm conical point is especially indicated for soft tissues, fascial planes and approaches in confined spaces, with controlled rotational movements and minimal injury. USP size 2 (metric 5) provides high tensile strength, suitable for soft tissue approximation, ligatures, ophthalmology and neurosurgery, where prolonged support is required.
Within the Cahnos catalogue you can complete the range with other presentations of the same family that allow unifying supplier and technical criteria:
- AM852HR4001 – polyester Premisut HR40, USP size 1, green, 75 cm (lower size of the same needle).
- AM852HRT4002 – polyester Premisut HRT40 (trocar point), USP size 2, green, 75 cm.
- AMP852HRT4030H – polyester Premisut Prime Heavy HRT40, USP size 3/0, green, 75 cm.
- AMP852HRT4502.4 – polyester Premisut Prime HRT45, USP size 2, green, 4×75 cm.
- AMP852HRT4810 – polyester Premisut Prime HRT48, USP size 0, green, 75 cm.
Before replacing brands, always check the needle angle (½), the size (40 mm), the point type (conical/taperpoint vs trocar), the USP size and the coating in the technical data sheet of the alternative manufacturer. Store below 30 °C, away from humidity and direct sunlight; as it is sterile single-use material, check the integrity of the packaging before each procedure and do not re-sterilise or reuse. For hospital volumes, centralised orders or other sizes and lengths on request, contact our technical-commercial team for a personalised quote.