Description
1. Product Presentation
We offer the nylon suture from the PREMISUT Prime range, reference AMP642RGS6030 (manufacturer ref. P642GS6030), a professional solution for B2B procurement for operating theatres, purchasing centres, general and specialist surgery services, as well as ophthalmology and neurosurgery units.
This presentation incorporates a straight conventional cutting needle GS 60 mm with 2 black threads of 75 cm (2×75 cm) in gauge USP 3/0, a highly demanded configuration for manual suturing on soft tissues with direct access, ligatures and precision surgery. Predictable behaviour, high tensile strength and special conditions for hospital supply and volume contracts.
2. Technical explanation of the material and procedure
The suture is made of nylon (polyamide 6 or 6.6) in a monofilament configuration: a single continuous, smooth and uncoated filament that minimises microorganism adherence, the sawing effect on tissue and the inflammatory reaction. Being non-absorbable, it maintains its structural integrity permanently and provides gradual encapsulation with great tensile strength, helping to support the wound for more than three months.
The straight needle model GS 60 mm, with a triangular conventional cutting point (Conventional Cutting), allows precise penetration into soft tissues without tearing; its straight shape is especially useful for continuous sutures, superficial approximations and direct-access ligatures. The black colour of the thread guarantees optimal contrast on the surgical field. The 2×75 cm presentation incorporates two 75 cm threads, which facilitates work in continuous or multi-point suturing techniques with a single unit. Ethylene oxide sterilisation ensures its sterile delivery, ready for immediate use; it is a single-use product and does not allow re-sterilisation.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference (SKU Cahnos) | AMP642RGS6030 |
| Manufacturer reference | P642GS6030 |
| Brand / Quality | PREMISUT Prime |
| Material | Nylon (polyamide 6 / 6.6), synthetic monofilament |
| Thread structure | Monofilament, uncoated |
| Gauge / USP size | USP 3/0 (metric 2 / EP 2) |
| Thread presentation | 2 strands of 75 cm (2×75 cm) |
| Thread colour | Black (high visibility in surgical field) |
| Needle shape | Straight |
| Tip type | Conventional cutting triangular point (Conventional Cutting) |
| Needle size | 60 mm (model GS 60) |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Sterilisation | Ethylene oxide (EO), sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units |
Gauge equivalence (non-absorbable suture, according to USP Pharmacopeia):
| USP size | Metric measurement (EP) | Approximate diameter |
|---|---|---|
| 3/0 | 2 | 0.20 – 0.249 mm |
Minimal tissue reaction, excellent tensile strength, secure knot and fully predictable behaviour as there is no polymer degradation in the body.
4. Equivalences and Cross-References
Non-absorbable monofilament nylon is one of the most widespread permanent suture families in the surgical market for soft tissue approximation and ligatures. There is no official equivalence table validated by the manufacturer that cross-references this specific configuration (straight conventional cutting needle GS 60 mm, USP 3/0 gauge, black, 2×75 cm) with references from other manufacturers; therefore, matches must be treated as functional comparisons and not as 1:1 interchangeable without technical validation.
| Manufacturer / Company | Line / Reference | Equivalence level | Differences and observations |
|---|---|---|---|
| Ethicon (Johnson & Johnson) | ETHILON, ref. 627H (USP 3/0, black, 75 cm, straight KS 60 mm needle) | Comparable in specifications, not interchangeable 1:1 | Code confirmed in Ethicon data sheets and authorised distributor catalogues. It matches in material, gauge, colour and thread length; the KS needle has a triangular reverse cutting point (reverse cutting) while the GS has conventional cutting, and the ETHILON presentation is a single thread (75 cm) compared to the 2×75 cm format of this reference: verify point geometry and regulatory traceability before substituting. |
| B. Braun | Dafilon, ref. C0932655 (USP 3/0 [EP 2], blue, 75 cm, straight needle GS 60) | Comparable by category | Confirmed in the official B. Braun catalogue the Dafilon GS 60 combination (straight cutting needle 60 mm) in blue; the black 3/0 version with this same needle has not been verified in official sources. Same material (polyamide) and same needle designation GS 60. |
| Atramat | Nylon, ref. U6043-N (USP 3/0, black, 75 cm, straight cutting needle PU-60 60 mm) | Directly comparable in specifications | Thread configuration identical in gauge, colour and length (75 cm), with a 60 mm straight cutting needle (PU-60). Confirm with the authorised distributor the exact point geometry and presentation (single thread in Atramat). |
Closing phrase: There is no equivalence table validated by the manufacturer for this configuration; before any formal substitution, verify in the alternative manufacturer’s technical data sheet the exact gauge, thread length, needle geometry and size, colour, surface treatment and regulatory classification (CE/MDR). Consult our technical-commercial department before using this information in tenders or direct substitution of references. The cited brands belong to their respective manufacturers and are mentioned only as an equivalence reference.
5. Selection tips and variants of interest
Assess the wound support time required by the tissue and the gauge according to the anatomical area: the USP 3/0 gauge (metric 2) is fine and very versatile, indicated for skin, subcutaneous tissue and delicate soft tissues, as well as for precision approximation in ophthalmology and neurosurgery. Always check the needle geometry: the straight GS conventional cutting needle is ideal for soft tissues with direct access and ligatures, while the 3/8 circle formats with reverse cutting (DS series) are oriented towards deep sutures and closed planes. The 2×75 cm presentation is especially practical for continuous or multi-point suturing techniques with a single unit.
Variants of interest within the Cahnos catalogue:
- AMP642GS6030: nylon Premisut Prime, straight needle GS 60 mm, USP 3/0, black, 75 cm (single thread).
- AM642GS6030: nylon Premisut standard quality, straight needle GS 60 mm, USP 3/0, black, 75 cm.
- AMP642RGS6020: nylon Premisut Prime, straight needle GS 60 mm, USP 2/0, black, 2×75 cm.
- AMP642GS6020: nylon Premisut Prime, straight needle GS 60 mm, USP 2/0, black, 75 cm (slightly thicker gauge).
- AMP642GS5020: nylon Premisut Prime, straight needle GS 50 mm, USP 2/0, black, 75 cm (shorter needle).
- AMP642DS2630: nylon Premisut Prime with 3/8 circle needle and reverse cutting (DS 26) for deep sutures.
As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply agreements or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews