Description
1. Commercial Introduction
The NYLON PREMISUT PRIME suture is Cahnos’s precision reference for operating theatres, aesthetic surgery clinics, purchasing centres and tenders that require a non-absorbable thread with predictable behaviour. This presentation mounts a ⅜ circle needle with an extra-long precision reverse cutting triangular point and a square body of 11 mm (XDS11 Prime profile) on a black monofilament thread of 75 cm in USP 7/0 gauge: the microsurgery format par excellence for fine skin, ophthalmology, neurosurgery and plastic and cosmetic surgery. The Prime finish guarantees a homogeneous surface, low tissue reactivity and reliable knot retention, with batch traceability for hospital purchasing management.
2. Technical Explanation
The thread is made of uncoated nylon monofilament (polyamide 6 or 6.6), a synthetic polymer with a smooth surface that offers very smooth passage through tissue, without wicking effect, with minimal bacterial adherence and low tissue reaction. Being non-absorbable, it does not degrade by enzymatic action: it undergoes gradual encapsulation by connective tissue and maintains tensile strength for more than three months, comfortably covering the critical healing phase in tissues subjected to prolonged tension.
The XDS11 Prime needle (⅜ circle, extra-long precision reverse cutting triangular point with long cutting edge and square body of 11 mm) concentrates the cutting edge at the tip and prevents the cut from widening in the tissue, reducing tearing and improving the aesthetics of the scar. The square body provides maximum stability in the needle holder. The USP 7/0 gauge (metric EP 0.5) is one of the finest in the range, ideal for maximum precision procedures, and the black colour guarantees immediate contrast of the thread on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Property | Specification |
| Brand / Quality | Premisut Prime (premium range) |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament, smooth non-grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 7/0 (metric EP 0.5); conforming to USP gauges and European Pharmacopoeia |
| Approximate thread diameter | 0.050 – 0.069 mm (according to USP Pharmacopoeia, synthetic non-absorbable suture) |
| Thread length | 75 cm (free end, without loop) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | ⅜ circle (3/8 circular) |
| Tip type | Triangular reverse cutting, extra-long precision (Reverse Extra Cutting) |
| Needle body | Square, maximum stability in needle holder |
| Needle size | 11 mm (XDS11 Prime profile) |
| Configuration | Single needle (1 × 75 cm) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, plastic and cosmetic surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P642XDS1170 |
| Reference Cahnos (SKU) | AMP642XDS1170 |
Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 7/0 | 0.5 | 0.050 – 0.069 mm |
4. Equivalences and Cross-References
The reference P642XDS1170 corresponds to the official nomenclature of the Premisut Prime range (XDS11 profile, extra-long precision reverse cutting needle with square body of 11 mm, USP 7/0 gauge, black thread of 75 cm) and Cahnos markets it keeping the factory reference without altering characters: no digit may be added, removed or reordered when ordering or tendering. Black non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercially of the ‘Ethilon’ type). There is no manufacturer-validated equivalence table cross-referencing this reference with other brands; comparisons between brands are functional, at category level, and not interchangeable 1:1, and must be confirmed against each manufacturer’s technical data sheet or IFU before use in tendering or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (J&J MedTech) | ETHILON® – black nylon monofilament, 7-0, 45 cm (18″), P-1 needle of 11 mm ⅜ circle, reverse cutting Prime | 1696G (confirmed in Ethicon EPC catalogue and authorised distribution: The Surgical Room, MAP Medical, MedicalEcart, Medex Supply) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6/6.6), gauge 7/0 (EP 0.5), black colour, ⅜ radius and needle size 11 mm; they differ in thread length (45 cm vs 75 cm) and profile: P-1 Prime standard reverse cutting versus XDS11 with extra-long cutting edge and square body. Verify IFU before substituting. |
| Medtronic (Covidien) | MONOSOF™ – black monofilament nylon, 7-0, 45 cm (18″), P-10 needle of 11 mm ⅜ circle, premium reverse cutting | SN-3686 (confirmed in Medtronic/Covidien catalogue and authorised distribution: McKesson, Hospeq, WestCMR, CIA Medical) | Comparable by category (not interchangeable 1:1) | Same material (nylon 6 and 6.6), gauge 7/0, black colour, ⅜ radius and 11 mm needle; they differ in thread length (45 cm vs 75 cm) and finish (P-10 premium reverse cutting from Surgalloy versus XDS11 Prime with extra-long cutting edge and square body). |
Other comparable houses in the segment to consider: DAFILON® from B. Braun (polyamide monofilament, black version in polyamide 6.6 indicated for microsurgery and ophthalmology, with DS needles of ⅜ circle inverted triangular point) and the nylon range from Serag-Wiessner (black, polyamide monofilament, covers USO gauges 11/0 to 8/0). For the exact configuration 7/0 black 75 cm with 11 mm reverse cutting needle, the specific code for these brands must be confirmed with the distributor and against the IFU before any substitution.
Mandatory technical note: there is no manufacturer-validated equivalence table cross-referencing this reference with other brands. Comparisons with ETHILON® or MONOSOF™ are functional, at category level, and must be confirmed against each manufacturer’s technical data sheet or IFU before use in tendering or direct substitution. This needle geometry (XDS11 Prime, USP 7/0, 75 cm) is only safely interchangeable within the Premisut system itself. Consult Cahnos’s technical department to validate any equivalence.
5. Selection tips and variants of interest
Tissue to suture: the USP 7/0 gauge (metric 0.5) is one of the finest in the catalogue and the microsurgery choice for very delicate planes (ophthalmology, neurosurgery) and fine skin. The precision XDS needle with extra-long cutting edge and square body reduces tearing and improves the aesthetics of the scar, being especially valued in plastic and cosmetic surgery.
Thread length: 75 cm is the usual operating theatre measure and offers ample margin for passes and knots; if the protocol requires a shorter length for reduced fields, the same XDS11 Prime 7/0 configuration is available in 45 cm (AMP641XDS1170).
Same XDS Prime family in nylon:
| Reference | Needle | USP | Length | Colour |
| AMP642XDS1170 | XDS 11 mm | 7/0 | 75 cm | Black (nylon) · product in this data sheet |
| AMP641XDS1170 | XDS 11 mm | 7/0 | 45 cm | Black |
| AMP642XDS1160 | XDS 11 mm | 6/0 | 75 cm | Black |
| AMP642XDS1360 | XDS 13 mm | 6/0 | 75 cm | Black |
| AMP642XDS1660 | XDS 16 mm | 6/0 | 75 cm | Black |
| AMP642DS1270 | DS 12 mm (standard reverse cutting) | 7/0 | 75 cm | Black |
Same needle, different material: if a non-absorbable suture with the same XDS 11 needle profile in polypropylene (blue) is required, consider the Polypropylene Premisut range (AMP732XDS1170, 7/0, 75 cm). Larger needle body: for slightly deeper accesses, the same configuration in XDS 13 mm or XDS 16 mm (AMP642XDS1360, AMP642XDS1660). Conventional vs. reverse cutting: if the protocol prefers a precision conventional cutting triangular point, consult the XNS family in the catalogue.
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P642XDS1170 and the batch number for traceability in the operating theatre. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other manufacturers, contact the technical-commercial team of Cahnos.