Description
1. Commercial Introduction
The NYLON Suture PREMISUT Prime 6/0 black, 75 cm, with 3/8 circle XDS 13 mm needle is the reference choice for ophthalmology, neurosurgery, plastic and cosmetic surgery services, as well as for purchasing centres looking for a high-performance non-absorbable thread with predictable clinical behaviour and full traceability.
This reference combines an uncoated, non-grooved polyamide 6 or 6.6 monofilament, USP gauge 6/0, black 75 cm thread, and an extra-long reverse precision cutting needle with a 13 mm square body (XDS profile), designed to penetrate firm tissues with minimal resistance and excellent stitch control. Its Prime quality guarantees a homogeneous surface, low tissue reactivity and reliable knot retention. Sterile product, ready to use, presented in a box of 12 units in individual sachets, with batch traceability.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue permanently, gradually becoming encapsulated by fibrous connective tissue. Being a monofilament and uncoated and non-grooved, the thread has a smooth surface that slides easily, reduces bacterial drag compared with multifilament sutures and minimises the inflammatory reaction, while maintaining high tensile strength for more than three months.
The XDS needle (⅜ circle, extra-long reverse precision cutting triangular point or reverse extra cutting, with a 13 mm square body) concentrates the cutting edge at the tip and prevents the cut from widening in the tissue, reducing tearing and improving scar aesthetics. The Prime finish provides optimised penetration and consistent grip in the needle holder. The USP 6/0 gauge (metric EP 0.7) offers a very fine diameter, ideal for superficial planes and delicate tissues. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the manufacturer/distributor (Cahnos S.L.).
| Parameter | Specification |
|---|---|
| Brand / Quality | PREMISUT Prime (premium range) |
| Thread material | Nylon – polyamide 6 or 6.6, uncoated monofilament |
| Thread structure | Monofilament, smooth non-grooved surface (without grooves) |
| Absorption | Non-absorbable; gradual encapsulation, tissue support longer than 3 months |
| Gauge / USP size | USP 6/0 (metric EP 0.7); conforms to USP and European Pharmacopoeia sizes |
| Approximate thread diameter | 0.07 – 0.099 mm (according to USP Pharmacopoeia, synthetic non-absorbable suture) |
| Thread length | 75 cm (free end, without loop) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | ⅜ circle (3/8) |
| Tip type | Triangular, extra-long reverse precision cutting (Reverse Extra Cutting, XDS profile) |
| Needle body / measurement | Square body, 13 mm (XDS 13 Prime profile) |
| Configuration | Single needle (1 × 75 cm) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use; do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology, neurosurgery and plastic/cosmetic surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| References | Manufacturer ref. P642XDS1360 · SKU Cahnos AMP642XDS1360 |
3.1. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 6/0 | 0.7 | 0.07 – 0.099 mm |
4. Equivalences and Cross-References
The reference P642XDS1360 corresponds to the manufacturer’s official nomenclature (PREMISUT Prime range, XDS 13 Prime profile) and Cahnos markets it without altering characters: do not add, remove or reorder digits when ordering or tendering. Black non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercial type «Ethilon»).
There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | ETHILON® – black nylon monofilament, 6-0, P-3 needle of 13.1 mm, ⅜ circle, reverse precision cutting, 45 cm | 1698G | Comparable by category (not interchangeable 1:1) | Same material (polyamide 6/6.6), gauge 6/0, black colour, monofilament and needle radius ⅜ circle with reverse cutting point of 13 mm. The length differs (45 cm vs 75 cm) and the exact precision profile (P-3 vs XDS 13 Prime). Code 1698G verified in the Ethicon catalogue and authorised distribution (GUDID). For the equivalent EMEA reference, contact the authorised distributor. |
| Medtronic (Covidien) | Monosof™ – black nylon monofilament, 6-0, P-13 needle of 13 mm, ⅜ circle, reverse precision cutting, 45 cm | SN-5696G | Comparable by category (not interchangeable 1:1) | It matches in material (nylon 6), gauge 6/0, black colour, ⅜ circle radius and needle size of 13 mm (reverse cutting). The length differs (45 cm vs 75 cm) and the precision profile (standard P-13 vs XDS 13 Prime with extra-long cutting edge and square body). Code verified in the authorised Medtronic distributor catalogue. |
| B. Braun (Aesculap) | DAFILON® – polyamide 6/6.6 (blue or colourless) or polyamide 6.6 (black) | C0932116 (blue DS 16 version) | Comparable by category (not interchangeable 1:1) | Same family of nylon monofilament, with a black variant (polyamide 6.6) aimed at microsurgery and ophthalmology. The needle geometry (DS vs XDS 13 Prime) and length may differ; confirm the code of the black 13 mm version with the distributor. |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; consult the technical department of Cahnos before using it as a substitute in tendering. This needle geometry (XDS 13 mm, square body, extra-long reverse precision cutting) is only safely interchangeable within the PREMISUT system itself. Before substituting in a surgical protocol, the following must be verified one by one against the technical data sheet and IFU of each manufacturer: exact needle shape and size, USP gauge, thread length, colour, regulatory classification (MDR) and sterility conditions. Other brands in the sector (e.g. Serag-Wiessner with SeraNyl®) offer black nylon monofilament in the same category, but no official 1:1 cross-reference code has been found for this exact configuration.
5. Selection tips and variants of interest
Tissue to suture: the XDS 13 Prime extra-long reverse cutting needle with square body is suitable for firm tissues and delicate skin planes, plastic and cosmetic surgery, ophthalmology and neurosurgery; for looser or vascular tissues, consider round-point profiles from the same range. The USP 6/0 gauge is ideal for very fine planes (microsurgery, ophthalmology, facial skin).
Variants of the XDS Prime family available at Cahnos:
| Reference | Needle | USP | Length | Colour |
|---|---|---|---|---|
| AMP642XDS1360 | XDS 13 mm (this product) | 6/0 | 75 cm | Black |
| AMP641XDS1360 | XDS 13 mm | 6/0 | 45 cm | Black |
| AMP642XDS1350 | XDS 13 mm | 5/0 | 75 cm | Black |
| AMP642XDS1340 | XDS 13 mm | 4/0 | 75 cm | Black |
| AMP642XDS1660 | XDS 16 mm | 6/0 | 75 cm | Black |
| AMP642XDS1160 | XDS 11 mm | 6/0 | 75 cm | Black |
| AMP732XDS1360 | XDS 13 mm (polypropylene) | 6/0 | 75 cm | Blue |
Same needle, different material: if you require a non-absorbable polypropylene suture with the same XDS 13 needle profile, consider the Polypropylene PREMISUT range (e.g. AMP732XDS1360, 6/0, 75 cm). Sterility verification: product sterilised by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use, and keep the reference P642XDS1360 together with the batch number for traceability in the operating theatre.





Reviews