We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

NYLON Suture PREMISUT Prime 3/8 Circle Triangular Point Reverse Precision Cutting XDS13 mm (13 mm, Square Body) – USP 6/0 (EP 0.7), Black, 45 cm – Box of 12 units (Ref. P641XDS1360)

51,86 €

NYLON suture PREMISUT Prime 6/0 (EP 0.7) black, 45 cm, non-absorbable, in polyamide 6/6.6 monofilament, uncoated and non-grooved. It mounts a ⅜ circle needle with triangular point, extra-long precision reverse cutting edge and square body of 13 mm (XDS13 Prime profile), designed for clean and controlled passage through delicate tissues with minimal tissue reaction and reliable knot retention. Indicated for soft tissue approximation, ligatures, ophthalmology, neurosurgery and plastic/cosmetic surgery. Sterilised by ethylene oxide (EO), single-use, in a box of 12 individual sachets with batch traceability. Factory ref. P641XDS1360 · SKU Cahnos AMP641XDS1360.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP641XDS1360

Description

1. Commercial Introduction

The NYLON PREMISUT Prime Suture is the precision reference for operating theatres, aesthetic surgery clinics, purchasing centres and tenders that need a non-absorbable thread with predictable behaviour and full traceability. This presentation mounts a ⅜ circle needle with a triangular point with extra-long precision reverse cutting and a square body of 13 mm (XDS13 Prime profile) on a black monofilament thread of 45 cm in USP 6/0 gauge (metric EP 0.7).

It is the microsurgery format par excellence for fine skin, ophthalmology, neurosurgery and plastic and cosmetic surgery. Sterile, single-use product with batch traceability, presented in a box of 12 units in individual sachets, ideal for unifying the permanent suture portfolio with a single B2B supplier.

2. Technical Explanation

The thread is made of uncoated monofilament nylon (polyamide 6 or 6.6), a synthetic polymer with a smooth surface that offers very smooth sliding through the tissue, without wicking effect, with minimal bacterial adherence and low tissue reaction. Being non-absorbable, it does not degrade by enzymatic action: it undergoes gradual encapsulation by the connective tissue and maintains tensile strength for more than three months, comfortably covering the critical healing phase.

The XDS13 Prime needle (⅜ circle, triangular point with extra-long precision reverse cutting, reverse extra cutting, with a 13 mm square body) concentrates the cutting edge at the tip and prevents the cut from widening in the tissue, reducing tearing and improving the aesthetics of the scar. The square body provides excellent stability in the needle holder. The USP 6/0 gauge (metric 0.7) is one of the finest in the range, ideal for maximum precision procedures, and the black colour guarantees immediate contrast of the thread on the surgical field.

3. Technical Specifications

Data verified according to the technical data sheet and instructions for use of the manufacturer/distributor (Cahnos S.L.).

3.1. General characteristics

Parameter Specification
Brand / Quality PREMISUT Prime (premium range)
Thread material Nylon – polyamide 6 or 6.6, uncoated monofilament
Thread structure Monofilament, smooth non-grooved surface (without grooves)
Absorption Non-absorbable; gradual encapsulation, tissue support longer than 3 months
Gauge / USP size USP 6/0 (metric EP 0.7); conforms to USP and European Pharmacopoeia sizes
Approximate thread diameter 0.070 – 0.099 mm (according to USP Pharmacopoeia, synthetic non-absorbable suture)
Thread length 45 cm (free end, without loop)
Thread colour Black identifier (high visibility in surgical field)
Needle shape ⅜ circle (3/8 circular)
Tip type Triangular, extra-long reverse precision cutting (Reverse Extra Cutting, XDS profile)
Needle body / measurement Square body, 13 mm (XDS 13 Prime profile)
Configuration Single needle (1 × 45 cm)
Sterilisation Ethylene oxide (EO) – sterile, single-use; do not re-sterilise
Indications Approximation of soft tissues, ligatures, ophthalmology, neurosurgery and plastic/cosmetic surgery
Commercial presentation Box of 12 units (sterile individual sachets); batch traceability
Factory reference P641XDS1360
Reference Cahnos (SKU) AMP641XDS1360

3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
6/0 0.7 0.070 – 0.099 mm

3.3. Premisut Prime XDS13 family (⅜ circle needle, square body, triangular point with precision reverse cutting)

Needle profile USP size Thread Reference
XDS 13 Prime 3/0 1 × 45 cm (black) P641XDS1330 / AMP641XDS1330
XDS 13 Prime 4/0 1 × 45 cm (black) P641XDS1340 / AMP641XDS1340
XDS 13 Prime 5/0 1 × 45 cm (black) P641XDS1350 / AMP641XDS1350
XDS 13 Prime 6/0 1 × 45 cm (black) P641XDS1360 / AMP641XDS1360 (this product)
XDS 13 Prime 6/0 1 × 75 cm (black) P642XDS1360 / AMP642XDS1360

4. Equivalences and Cross-References

The reference P641XDS1360 corresponds to the official nomenclature of the PREMISUT Prime range (XDS13 profile, extra-long precision reverse cutting needle with 13 mm square body, USP 6/0 gauge, 45 cm black thread) and Cahnos markets it without altering characters: no digit should be added, removed or reordered when ordering or tendering. Non-absorbable black monofilament nylon is one of the most standardised permanent suture families on the market (commercially type «Ethilon»).

There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; consult the technical department of Cahnos before using in tenders or direct substitution. The following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before clinical use.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (J&J MedTech) ETHILON® – black monofilament nylon, 6-0, 18″ (45 cm), P-3 needle of 13 mm ⅜ circle, precision reverse cutting 1698G (confirmed in official Ethicon EPC catalogue and authorised distribution) Comparable by category (not interchangeable 1:1) They match in material (polyamide), gauge 6/0 (EP 0.7), black colour, length 45 cm, radius ⅜ and needle size 13 mm with reverse cutting point. The exact precision profile differs (P-3 versus XDS13 Prime with extra-long cutting edge and square body) and the EMEA nomenclature (request equivalent code from the authorised distributor).
Medtronic (Covidien) MONOSOF™ – black monofilament nylon, 6-0, 18″ (45 cm), C-12 needle 12 mm ⅜ circle, reverse cutting SN660 / SN-660 (confirmed in Medtronic catalogue and authorised distribution) Comparable by category (not interchangeable 1:1) Same material (nylon 6 and 6.6), gauge 6/0, black colour, length 45 cm and radius ⅜; 12 mm needle within tolerance of 13 mm. The needle body differs (standard C-12 versus XDS13 Prime with extra-long precision and square body).
DemeTECH (DemeLON™) DemeLON™ – black monofilament nylon, 6/0, DS-2 needle of 12 mm ⅜ circle, reverse cutting, 45 cm NL166012F4P (confirmed in official DemeTECH store and authorised distribution) Comparable by category (not interchangeable 1:1) Same material (polyamide nylon 6/6.6), gauge 6/0, black colour, length 45 cm and radius ⅜; 12 mm needle within tolerance. The cutting type differs (standard reverse cutting versus XDS13 extra-long precision reverse cutting with square body).
B. Braun (Aesculap) DAFILON® – monofilament polyamide, 6/0 (EP 0.7), 45 cm, DS16 needle ⅜ circle, reverse cutting C0932116 (confirmed in official B. Braun catalogue; blue version) Comparable by category (not interchangeable 1:1) They match in material (polyamide), gauge 6/0, diameter, length 45 cm and radius ⅜. Differences: blue colour versus black, DS16 needle of 16 mm (outside tolerance of 13 mm) and standard finish versus XDS13 Prime precision with square body. The black Dafilon variant (polyamide 6.6) exists for microsurgery, but its specific reference in this configuration must be confirmed.

Mandatory technical note: this needle geometry (XDS13 mm, square body, extra-long precision reverse cutting) is only fully safely interchangeable within the PREMISUT system itself. Before substituting in a surgical protocol, the following must be verified one by one against the technical data sheet and IFU of each manufacturer: exact shape and size of the needle, USP gauge, thread length, colour, regulatory classification (MDR) and sterility conditions.

5. Selection tips and variants of interest

Tissue to suture: the USP 6/0 gauge (metric 0.7) is the microsurgery choice for very delicate tissue planes (ophthalmology, neurosurgery) and fine skin. The precision XDS needle with extra-long cutting edge and square body reduces tearing and improves scar aesthetics, being especially valued in plastic and cosmetic surgery.

Thread length: this 45 cm reference is the standard operating theatre measure and offers good margin for passes and knots in reduced surgical fields; if the protocol requires more thread per unit, the same XDS13 Prime 6/0 configuration is available with 75 cm thread (AMP642XDS1360).

Variant / Reference Description
AMP642XDS1360 NYLON Prime XDS13 mm 6/0 black 75 cm (same profile and gauge, longer thread length)
AMP641XDS1160 NYLON Prime XDS11 mm 6/0 black 45 cm (extreme precision microsurgery)
AMP641XDS1660 NYLON Prime XDS16 mm 6/0 black 45 cm (same reverse cutting point, longer needle)
AMP641XDS1350 NYLON Prime XDS13 mm 5/0 black 45 cm (slightly thicker gauge, same needle)
AMP641XNS1360 NYLON Prime XNS13 mm 6/0 black 45 cm (precision conventional cutting triangular point)
AMP541XNS1660 SILK Prime XNS16 mm 6/0 black 45 cm (non-absorbable braided silk, same needle profile)

Sterility verification: product sterilised by ethylene oxide and single-use; check the blister integrity and expiry date before each use, and keep the reference P641XDS1360 together with the batch number for traceability in the operating theatre. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Material

Nylon (polyamide 6 or 6.6), uncoated monofilament

Structure

Non-grooved monofilament

Absorption

Non-absorbable (gradual encapsulation; tissue support > 3 months)

Metric gauge (EP)

0.7 mm

Thread diameter

0.070 – 0.099 mm

Needle shape

⅜ circle (3/8 circular)

Needle type

Triangular point, extra-long reverse precision cutting (Reverse Extra Cutting)

Needle size

13 mm (XDS 13 Prime)

Needle body

Square

Swaged

1 needle (1 × 45 cm)

Quality

Prime (premium range)

Sterilisation

Ethylene oxide (EO), single-use

Indications

Approximation of soft tissues, ligatures, ophthalmology, neurosurgery, plastic and cosmetic surgery

Presentation

Box of 12 units (individual sterile sachets)

Manufacturer reference

P641XDS1360

Medida de aguja

XDS 13

Usp

6/0

Color

Black

Medida de hilo

45 cm

Tipo de aguja

Precision triangular

Forma de aguja

3/8 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “NYLON Suture PREMISUT Prime 3/8 Circle Triangular Point Reverse Precision Cutting XDS13 mm (13 mm, Square Body) – USP 6/0 (EP 0.7), Black, 45 cm – Box of 12 units (Ref. P641XDS1360)”

Your email address will not be published. Required fields are marked *