Description
1. Product Presentation
The NYLON suture PREMISUT Prime, factory reference P641XDS1950 (SKU Cahnos AMP641XDS1950), is the precision choice for surgical departments, purchasing centres and tenders that need a non-absorbable thread with predictable behaviour. It mounts a ⅜ circle needle with extra-long precision reverse cutting triangular point and square body of 19 mm (XDS19 Prime profile), USP 5/0 gauge and black thread of 45 cm: a configuration designed for aesthetic skin closure and approximation of soft tissues, with special value in plastic and cosmetic surgery, ophthalmology and neurosurgery. Sterile, single-use product with batch traceability, presented in a box of 12 units in individual sachets.
2. Technical Explanation
The thread is made of uncoated nylon monofilament (polyamide 6 or 6.6), a synthetic polymer with a smooth surface that offers very smooth sliding through tissue, without wicking effect, with minimal bacterial adherence and low tissue reaction. Being non-absorbable, it does not degrade by enzymatic action: it undergoes gradual encapsulation by connective tissue and maintains tensile strength for more than three months, comfortably covering the critical healing phase in tissues subjected to prolonged tension.
The ⅜ circle needle with extra-long precision reverse cutting triangular point (Reverse Extra Cutting) and square body of 19 mm concentrates the cutting edge at the tip and prevents the cut from widening in the tissue, reducing tearing and improving the aesthetics of the scar. The Prime finish provides optimised penetration and consistent grip in the needle holder. The black colour guarantees immediate contrast of the thread on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the manufacturer/distributor (Cahnos S.L.).
| Parameter | Specification |
|---|---|
| Brand / Quality | Premisut Prime (premium range) |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament, smooth non-grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, support for more than 3 months |
| Gauge / USP size | USP 5/0 (metric 1); conforming to USP and European Pharmacopoeia gauges |
| Approximate thread diameter | 0.100 – 0.149 mm (according to USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 45 cm (free end, without loop) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Tip type | Triangular reverse cutting, extra-long precision (Reverse Extra Cutting) |
| Needle body | Square, 19 mm (XDS19 Prime profile) |
| Configuration | Single needle (1 × 45 cm) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, plastic and cosmetic surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P641XDS1950 |
| Reference Cahnos (SKU) | AMP641XDS1950 |
3.1. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 5/0 | 1 | 0.100 – 0.149 mm |
3.2. Family Premisut Prime XDS (reverse cutting precision, square body, black)
| Needle profile | USP size | Thread | Reference |
|---|---|---|---|
| XDS 19 prime | 5/0 | 1 × 45 cm (black) | P641XDS1950 / AMP641XDS1950 (this product) |
| XDS 19 prime | 5/0 | 1 × 75 cm (black) | P642XDS1950 / AMP642XDS1950 |
| XDS 19 prime | 4/0 | 1 × 45 cm (black) | P641XDS1940 / AMP641XDS1940 |
| XDS 19 prime | 3/0 | 1 × 45 cm (black) | P641XDS1930 / AMP641XDS1930 |
| XDS 19 prime | 3/0 | 1 × 75 cm (black) | P642XDS1930 / AMP642XDS1930 |
| XDS 13 prime | 5/0 | 1 × 75 cm (black) | P642XDS1350 / AMP642XDS1350 |
4. Equivalences and Cross-References
The reference P641XDS1950 corresponds to the official nomenclature of the Premisut Prime range (XDS19 profile, extra-long precision reverse cutting needle with square body of 19 mm, USP 5/0 gauge, black thread of 45 cm) and Cahnos markets it without altering characters. Black non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercially type «Ethilon»). There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons between brands are functional, at category level, and not interchangeable 1:1, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution. The main difference compared to the cited external references is the XDS19 Prime precision needle (extra-long cutting edge and square body), designed specifically for plastic/cosmetic surgery.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (J&J MedTech) | ETHILON® – black nylon monofilament, 5-0, 45 cm, PS-2 needle of 19 mm ⅜ circle | 1666G | Comparable by category (not interchangeable 1:1) – code confirmed | Same material (polyamide), gauge 5/0, black colour, length 45 cm and needle radius ⅜ of 19 mm with reverse cutting Prime; the precision profile differs: PS-2 versus XDS19 with extra-long edge and square body. Verified in Ethicon catalogue and authorised distribution. |
| Medtronic (Covidien) | Monosof™ – black nylon monofilament, 5-0, 45 cm, C-13 needle of 19 mm ⅜ circle | SN-661 / SN-661G | Comparable by category (not interchangeable 1:1) – code confirmed | Same material (nylon 6 and 6.6), gauge, colour, length and needle geometry (⅜ circle reverse cutting 19 mm); the precision profile differs (C-13 versus XDS19) and the box format (36/12). Verified in Medtronic catalogue and authorised distribution. |
| B. Braun (Aesculap) | Dafilon® – polyamide monofilament, 5/0, 45 cm, DS19 needle of 19 mm ⅜ circle | C0932191 | Comparable by category (not interchangeable 1:1) – code confirmed | Same gauge, length and needle radius (⅜ circle reverse cutting 19 mm); the colour differs (blue versus black) and the standard DS needle, not equivalent to the precision XDS. The black variant of Dafilon is intended for microsurgery and ophthalmology; confirm black code in B. Braun catalogue. |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with ETHILON®, Monosof™ or Dafilon® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution. This needle geometry (XDS19 Prime, USP 5/0, 45 cm) is only safely interchangeable within the Premisut system itself. Consult the technical department of Cahnos to validate any equivalence.
5. Selection tips and variants of interest
- Tissue to suture: the USP 5/0 gauge (metric 1) is suitable for skin and soft tissues with low tension. For very delicate planes (microsurgery, ophthalmology) consider higher gauges of the same range, such as XDS13 or XDS11 in 6/0 (e.g. AMP642XDS1360).
- Thread length: this 45 cm reference offers good margin for passes and knots in reduced surgical fields; if the protocol requires more thread, the 75 cm variant is available within the same XDS19 family (AMP642XDS1950).
- Aesthetic closure: for plastic and cosmetic surgery, keep the precision XDS needle: the extra-long cutting edge and square body reduce tearing and improve the scarring outcome.
- Other geometries: if the protocol requires a standard body reverse cutting (not precision), refer to the DS family (e.g. DS19 Prime 5/0 45 cm, SKU AMP641DS1950); for taperpoint conical point, the DR family (e.g. AMP642DR1360 in 6/0).
- Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P641XDS1950 and the batch number for traceability in the operating theatre. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team of Cahnos.





Reviews