Description
1. Commercial Introduction
The Nylon Suture PREMISUT Prime in configuration 3/8 Triangular DS40mm is the reference option for professionals who need a high-strength permanent thread with double strand: 2 threads of 90 cm of black monofilament nylon, mounted on a ⅜ circle needle with reverse cutting triangular point of 40 mm. Designed for ophthalmology, neurosurgery and general surgery services, it offers predictable clinical behaviour, excellent knot retention and the complete traceability required by hospital environments and tenders. Sterile, single-use product, presented in a box of 12 units in individual sachets.
2. Technical Explanation
The thread is manufactured in nylon (polyamide 6 or 6.6) in a uncoated monofilament structure with a grooved surface, which favours smooth sliding through tissues, reduces the wick effect and bacterial drag compared with multifilament, and minimises inflammatory reaction. Being non-absorbable, it remains in the tissue, gradually encapsulating, and maintains high tensile strength for more than three months, comfortably covering the critical healing phase.
The DS40 needle features a ⅜ circle curvature with a reverse cutting triangular point: the cutting edge cuts in the opposite direction to the wound, preserving the skin edge and preventing the cut from widening in the puncture bed; it is ideal for firm, poorly distensible tissues. This reference incorporates 2 needles with 2 threads of 90 cm, a configuration designed for procedures requiring multiple stitches or continuous sutures without re-threading. The USP 2 gauge (metric EP 5) provides high strength for tissues with medium-high tension and retention sutures.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / quality | PREMISUT Prime |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament, grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 2 (metric EP 5) |
| Approximate thread diameter | 0.45 – 0.499 mm (according to USP Pharmacopoeia, synthetic non-absorbable suture) |
| Thread length | 2 × 90 cm (double strand) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | 3/8 circle (⅜ circular) |
| Tip type | Triangular reverse cutting (Reverse Cutting) |
| Needle size | DS 40 (40 mm) |
| Configuration | 2 needles per unit, 2 fluted threads of 90 cm |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Reference Cahnos (SKU) | AMP643DS4002.2 |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 2 | 5 | 0.45 – 0.499 mm |
4. Equivalences and Cross-References
The reference AMP643DS4002.2 corresponds to the official nomenclature of the PREMISUT Prime range (DS40 profile: ⅜ circle needle with reverse cutting triangular point of 40 mm, USP 2 gauge, black grooved thread of 90 cm, double presentation). Black non-absorbable monofilament nylon is one of the most standardised permanent suture families on the market (commercially of the ‘Ethilon’ type).
There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or the instructions for use (IFU) of each manufacturer before use in tenders or direct substitution. In this specific configuration (DS40 of 40 mm, USP 2, 2×90 cm) no exact 1:1 equivalent from another house has been found in public sources; candidates with identical material (black monofilament polyamide) and same gauge, such as Ethicon ETHILON (nylon monofilament), B. Braun Dafilon® (black polyamide 6.6, ophthalmology and microsurgery line) and SMI/B. Braun Supramid® (polyamide pseudomonofilament), must be checked property by property —needle measurement and geometry, length and number of strands, colour, sterilisation method and regulatory classification (CE/MDR)— before any substitution. Closing sentence: there is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.
5. Selection tips and variants of interest
- Tissue to suture: the USP 2 gauge (EP 5) offers maximum strength for firm subcutaneous tissue, fasciae, aponeuroses, skin closures under tension and retention sutures. The reverse cutting needle penetrates dense tissues without tearing the puncture bed.
- Same DS40 geometry, single thread: if the procedure requires the same needle profile and gauge but with a single strand, use reference AMP643DS4002 (Prime, 1×90 cm) or the standard range AM643DS4002. For other 2×90 cm presentations, consider AMP643DS4001.2 (USP 1) and AMP643DS4020.2 (USP 2/0).
- Long-body needle: for deep access and wide fields, the same family offers the DS90 profile of 90 mm in AMP643DS9002 (Prime) and AM643DS9002 (standard range).
- Other curvatures in the line: in a ½ circle needle with reverse cutting triangular point of 40 mm, reference AM647HS4001 (USP 1, 100 cm) complements the range for reduced surgical fields.
- Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the batch number for traceability in the operating theatre. Store below 30 °C, away from humidity and direct sunlight.