Description
1. Commercial Introduction
The NYLON PREMISUT Prime suture in USP 2 gauge is the reference choice for surgical departments, ophthalmology, neurosurgery and purchasing centres looking for a permanent, high-resistance thread with predictable behaviour. Its monofilament of polyamide 6 or 6.6, uncoated and dyed black, offers smooth tissue passage, minimal inflammatory reaction and maintained tensile strength for more than three months. Each box contains 12 individual sterile pouches with batch traceability, facilitating hospital stock management and presentation for public tenders.
2. Technical Explanation
The thread is manufactured from uncoated nylon monofilament (polyamide 6 or 6.6): as it has no interstices, it produces no wicking effect, reduces bacterial carryover compared to multifilament sutures and minimises tissue reaction. Being a non-absorbable suture, it remains in the tissue, gradually encapsulating, maintaining wound approximation for more than three months, which comfortably covers the critical healing phase in tissues requiring prolonged support.
The DS40 needle has a ⅜ circle curve with a reverse cutting triangular point: the cutting edge cuts in the opposite direction to the puncture bed, preserving the skin edge and preventing the cut from widening, ideal for firm, non-distensible tissues. The Prime finish provides improved penetration with less resistance. The USP 2 gauge (metric EP 5) offers high tensile strength, suitable for planes under significant tension. Product sterile by ethylene oxide, single-use and non-resterilisable.
3. Technical Specifications
| Parameter | Specification |
| Brand / quality | PREMISUT Prime (premium range, grooved needle) |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated, dyed black |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 2 (metric EP 5) |
| Approximate thread diameter | 0.45 – 0.499 mm (USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 90 cm (single strand) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | 3/8 circle (⅜ circular) |
| Tip type | Triangular reverse cutting (Reverse Cutting), fluted |
| Needle size | DS 40 (40 mm) Prime |
| Configuration | 1 needle per unit, 1 suture of 90 cm |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; ophthalmology, neurosurgery and general surgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Manufacturer reference (family pattern) | P643DS4002 |
| Reference Cahnos (SKU) | AMP643DS4002 |
Gauge equivalence (USP / EP Pharmacopoeia, synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 2 | 5.0 | 0.45 – 0.499 mm |
Family PREMISUT Prime DS40 (needle ⅜ circle, reverse cutting triangular point, black)
| Needle profile | USP size | Presentation | Factory reference |
| DS 40 Prime | 2 | 1 × 90 cm (single strand) | P643DS4002 (this product) |
| DS 40 Prime | 2 | 2 × 90 cm (double thread) | P643RDS4002.2 |
| DS 40 Prime | 1 | 1 × 90 cm (single strand) | P643DS4001 |
| DS 40 Prime | 2/0 | 1 × 90 cm (single strand) | P643DS4020 |
4. Equivalences and Cross-References
Black non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercial type ‘Ethilon’). There is no equivalence table validated by the manufacturer that officially cross-references this product with other brands; consult the technical department before using in tenders. In this specific configuration (DS40 needle of 40 mm, USP 2, single strand of 90 cm) no exact 1:1 equivalent from another brand has been found in public sources: market candidates match in material, colour and needle point family, but differ in gauge, needle size or length, and are therefore not interchangeable 1:1 without technical validation.
Homologous families on the market to review property by property before any substitution: ETHILON™ (Ethicon / J&J MedTech, black nylon monofilament), MONOSOF™ (Medtronic, black nylon monofilament), DAFILON® (B. Braun, black polyamide 6.6, microsurgery and ophthalmology line), DemeLON™ (DemeTECH, black nylon monofilament) and LUXAMID® / SUPRAMID® (LuxSutures / SMI). No codes from these brands have been verified in public sources for the exact configuration DS40 of 40 mm, USP 2 and 90 cm, so they must be confirmed with the manufacturer before use in substitution or tender.
5. Selection tips and variants of interest
- Tissue to suture: the USP 2 gauge (metric EP 5) offers high tensile strength for deep planes, fascias, aponeuroses and tissues under high tension; the reverse cutting needle penetrates firm tissues without tearing the puncture bed. If a smaller gauge is required on the same DS40 needle, consider the USP 1 version (SKU AMP643DS4001) or USP 2/0 (SKU AMP643DS4020).
- Presentation: to reduce pouch opening per procedure, the family offers a double version 2 × 90 cm in this same gauge (SKU AMP643DS4002.2); if you are looking for the standard range (not Prime), the reference AM643DS4002 maintains the same DS40 needle, gauge 2 and length of 90 cm.
- Other geometries: in a ½ circle needle with reverse cutting triangular point, the reference AM647HS4001 (USP 1, 100 cm) complements the range for reduced surgical fields; for vascular or lax tissues, consider the HR conical point profiles from the same PREMISUT family.
- Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each procedure, and keep the reference P643DS4002 and batch number for traceability in the operating theatre. Store below 30 °C, away from humidity and direct sunlight.