Description
1. Commercial Introduction
The Suture NYLON PREMISUT Prime 2/0 black 2×75 cm is the reference solution in Cahnos’s premium range of non-absorbable sutures for procedures on soft tissues that demand reliability, clean passage and secure knotting. It combines an uncoated nylon monofilament (polyamide 6 or 6.6), with a fluted black colour for maximum visibility in the surgical field, with a 3/8 circle reverse cutting triangular point needle of 26 mm (DS 26 prime profile). Its double presentation of 2 strands of 75 cm per pouch makes it a cost-effective option for general surgery, dermatology, ophthalmology, neurosurgery departments and purchasing centres seeking full traceability and predictable clinical performance. Sterile product, ready to use, supplied in a box of 12 individual pouches.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely: it gradually becomes encapsulated by fibrous connective tissue and maintains a high tensile strength for more than three months, comfortably covering the critical healing phase. Being an uncoated monofilament, the strand slides easily through tissues, reduces the saw effect, minimises bacterial adherence compared to multifilament sutures and promotes a firm, stable knot; its fluted finish provides an extra point of security in the approximation of soft tissues, minimising the risk of accidental slippage.
The 3/8 circle needle with reverse cutting triangular point concentrates the cutting edge on the convex side of the arc and cuts outward from the wound, avoiding tearing of the skin edge; the fluted body of the DS 26 prime needle improves the grip of the needle holder and torque transmission. This geometry is intended for skin, mucous membranes and firm tissues of medium consistency, with a clean entry hole and a quality cosmetic result.
3. Technical Specifications
| Parameter | Specification |
| Brand / Quality | Premisut Prime (premium range) |
| Thread material | Nylon (polyamide 6 or 6.6), uncoated monofilament |
| Structure | Monofilament, grooved finish |
| Absorption | Non-absorbable; gradual encapsulation, retains tensile strength for more than 3 months |
| Gauge | USP 2/0 (metric EP 3), conforming to USP and European Pharmacopoeia gauges |
| Thread length | 2 strands of 75 cm (double presentation 2 x 75 cm) |
| Colour | Black (high visibility in surgical field) |
| Needle shape | 3/8 circle (3/8 circular) |
| Tip type | Reverse cutting triangular (reverse cutting), DS standard profile |
| Needle size | DS 26 prime (26 mm) |
| Swaged | 2 strands of 75 cm with 3/8 reverse cutting triangular needle |
| Sterilisation | Ethylene oxide (EtO), sterile; single use, do not re-sterilise |
| Indications | Soft tissue approximation, ligatures, ophthalmology, neurosurgery and skin surgery |
| Presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P642DS2620.2 |
| Reference Cahnos (SKU) | AMP642DS2620.2 |
Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture):
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 2/0 | 3 | 0.30 – 0.339 mm |
4. Equivalences and Cross-References
The reference P642DS2620.2 corresponds to the official nomenclature of the Premisut Prime range (series 642: DS 26 prime reverse cutting needle, USP 2/0 gauge, two strands of 75 cm in fluted black) and Cahnos markets it without altering characters: no digit should be added, removed or reordered when ordering or tendering.
There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; consult the technical department before using in tendering or substitution. The following comparisons are functional, at category level, and have been cross-checked against official catalogues and authorised distribution; they must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | ETHILON™ – black nylon monofilament, 2/0, 75 cm, PS Prime needle of 26 mm 3/8 circle, reverse cutting | W1626BH | Comparable by category (not interchangeable 1:1) | Code confirmed in official Ethicon EMEA catalogue and authorised distribution. It matches in material (polyamide), gauge 2/0, black colour, suture length (75 cm), 3/8 circle radius and Prime needle of 26 mm; it differs in presentation (1 strand vs. 2 strands) and needle profile (PS Prime vs. DS). Verify IFU before substituting. |
| Medtronic (Covidien) | MONOSOF™ – black nylon monofilament, 2/0, 75 cm (30″), C-15 needle of 26 mm 3/8 circle, reverse cutting | SN-664 | Comparable by category (not interchangeable 1:1) | Code confirmed in Medtronic catalogue and authorised distribution. Same non-absorbable material (nylon 6 and 6.6), gauge 2/0, black colour, needle size (26 mm) and length (75 cm); it differs in presentation (1 strand vs. 2 strands) and needle profile (standard C-15 vs. DS prime). Confirm presentation before substituting. |
| B. Braun | DAFILON® – blue polyamide monofilament, 2/0 (EP 3), 75 cm, DS24 needle 3/8 circle, reverse cutting | C0935360 | Comparable by category (not interchangeable 1:1) | Code confirmed in official B. Braun catalogue. Same material (polyamide), gauge 2/0 (EP 3) and length 75 cm; it differs in colour (blue vs. black), needle (DS24 of 24 mm vs. DS26 of 26 mm) and presentation (1 strand vs. 2 strands). Black Dafilon (polyamide 6.6) is used in microsurgery and ophthalmology; confirm the code of the black version with the manufacturer. |
Technical note: the DS 26 prime reverse cutting needle geometry of the Premisut range can only be safely interchanged within the Premisut system itself. Consult the technical department of Cahnos to validate any equivalence before use in tendering.
5. Selection tips and variants of interest
Tissue to suture: the DS 26 prime reverse cutting needle is suitable for skin, mucous membranes and firm tissues of medium consistency, as well as for approximation of soft tissues and ligatures. For vascular or lax planes consider round point profiles of the same range.
Gauge: USP 2/0 (EP 3) offers an optimal balance between strength and manageability for skin, subcutaneous tissue and medium-tension ligatures; for finer planes consider 3/0, 4/0 or 5/0 from the same family, and for fasciae or higher loads, larger gauges.
Thread length: this reference provides 2 threads of 75 cm (147 cm useful per pack), ideal for high-consumption surgical programmes. If the protocol requires a single thread, the same needle and gauge are available in 75 cm or 45 cm presentations.
| Variant (SKU Cahnos) | Description |
| AMP642DS2620 | NYLON Prime DS 26 mm – 2/0 black – 1 x 75 cm |
| AMP641DS2620 | NYLON Prime DS 26 mm – 2/0 black – 45 cm |
| AMP642DS2630.2 | NYLON Prime DS 26 mm – 3/0 black – 2 x 75 cm (same needle, finer gauge) |
| AMP642DS2420.2 | NYLON Prime DS 24 mm – 2/0 black – 2 x 75 cm (shorter needle) |
| AMP642XDS2630 | NYLON Prime XDS 26 mm (precision reverse cutting, square body) – 3/0 black – 75 cm |
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use, and keep the reference P642DS2620.2 together with the batch number for traceability in the operating theatre. For B2B volume conditions, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.