Description
1. Commercial Introduction
The PREMISUT PRIME nylon suture is the reference choice for operating theatres, purchasing departments and tenders that need a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle that penetrates tissue with total control. This presentation in USP 10/0 gauge mounts a ⅜ circle needle with cylindrical body and taper point conical tip of 3.8 mm (DR 3.8 Prime profile) and a 15 cm thread in black, designed for the most demanding surgery: ophthalmology, neurosurgery, vascular microsurgery and precision procedures on soft tissues.
It is supplied sterile and ready for individual use in a box of 12 units with batch traceability, which facilitates hospital stock management and presentation to public tenders. It is marketed under the factory reference P649DR3.8100, kept without altering characters, in a B2B format ideal for hospital replenishment and tenders.
2. Technical Explanation
Nylon or polyamide (6 or 6.6) is presented as an uncoated, non-grooved monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not promote bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by connective tissue, helping the wound for more than three months.
The DR 3.8 Prime needle (⅜ circle, cylindrical body with sharp taper point conical tip) penetrates soft tissues by separating fibres without cutting them, which reduces tissue trauma and is especially valued in delicate ocular, vascular and nervous structures. The USP 10/0 gauge (EP metric 0.2) is an ultra-fine thread with adequate strength to approximate very fine tissues with minimal residue. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated, dyed black |
| Thread structure | Monofilament, smooth non-grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 10/0 (metric EP 0.2); in accordance with USP and European Pharmacopoeia gauges |
| Indicative thread diameter | 0.020 – 0.029 mm |
| Thread length | 15 cm (1 strand per unit) |
| Thread colour | Black |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Cylindrical body, conical tip (taperpoint) |
| Needle size | 3.8 mm (DR 3.8 Prime profile) |
| Number of needles | 1 (single-armed) |
| Manufacturing quality | Prime (premium range) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P649DR3.8100 |
| SKU Cahnos | AMP649DR3.8100 |
3.2. Premisut Prime DR family in nylon (⅜ circle, cylindrical, conical tip) – 15 cm presentation
| Needle profile | USP | Presentation | Reference |
| DR 3.8 Prime | 11/0 | 1 × 15 cm | P649DR3.8110 / AMP649DR3.8110 |
| DR 3.8 Prime | 10/0 | 1 × 15 cm | P649DR3.8100 / AMP649DR3.8100 (this product) |
| DR 3.8 Prime | 9/0 | 1 × 15 cm | P649DR3,890 / AMP649DR3,890 |
| DR 4.7 Prime | 9/0 | 1 × 15 cm | P649DR4,790 / AMP649DR4,790 |
| DR 5.1 Prime | 10/0 | 1 × 15 cm | P649DR5.1100 / AMP649DR5.1100 |
| DR 5.1 Prime | 9/0 | 1 × 15 cm | P649DR5,190 / AMP649DR5,190 |
| DR 6.5 Prime | 10/0 | 1 × 15 cm | P649DR6.5100 / AMP649DR6.5100 |
3.3. Gauge conformity (indicative according to USP Pharmacopoeia, synthetic non-absorbable suture)
| USP size | EP metric measure | Indicative diameter | Thread length |
| 10/0 | 0.2 | 0.020 – 0.029 mm | 15 cm |
4. Equivalences and Cross-References
The reference P649DR3.8100 corresponds to the official nomenclature of the Premisut Prime range (DR 3.8 Prime profile, individual taper point needle of 3.8 mm, USP 10/0 gauge, black thread of 15 cm). Cahnos markets the product keeping the factory reference without altering characters.
There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut Prime range (Cahnos) | Nylon DR 3.8 Prime, USP 9/0, black, 15 cm | P649DR3,890 / AMP649DR3,890 | Configuration equivalent within the same system | Same conical needle of 3.8 mm, same material, colour and length; 9/0 gauge somewhat stronger than 10/0 |
| Premisut Prime range (Cahnos) | Nylon DR 3.8 Prime, USP 11/0, black, 15 cm | P649DR3.8110 / AMP649DR3.8110 | Configuration equivalent within the same system | Same conical needle of 3.8 mm, same material, colour and length; USP 11/0 gauge (EP 0.1) of greater fineness |
| Premisut Prime range (Cahnos) | Nylon DR 5.1 Prime, USP 10/0, black, 15 cm | P649DR5.1100 / AMP649DR5.1100 | Configuration equivalent within the same system | Same material, gauge and length; conical needle of 5.1 mm compared to 3.8 mm |
| Premisut Prime range (Cahnos) | Nylon DR 6.5 Prime, USP 10/0, black, 15 cm | P649DR6.5100 / AMP649DR6.5100 | Configuration equivalent within the same system | Same material, gauge and length; conical needle of 6.5 mm compared to 3.8 mm |
| Ethicon (Johnson & Johnson MedTech) | ETHILON® – black monofilament nylon, USP 10/0, 13 cm (5″), BV75-3 needle ⅜ circle taper point of 3.8 mm | 2870G (verified in official Ethicon catalogue, authorised distributors and GUDID/FDA) | Functional equivalence by specifications, not interchangeable 1:1 | They match material (polyamide 6/6.6), gauge 10/0, black colour, ⅜ radius, taper point and needle size 3.8 mm; thread of 13 cm compared to 15 cm; confirm presentation and batch against IFU |
| B. Braun | DAFILON® – black polyamide monofilament, USP 10/0 (EP 0.2), 15 cm, DRm6 micro-needle ⅜ circle round body of 6.0 mm | G1118013 (verified in official B. Braun catalogue) | Functional equivalence by specifications, not interchangeable 1:1 | High match: gauge 10/0 (EP 0.2), length 15 cm, black colour and ⅜ shape; DRm6 needle of 6.0 mm compared to taper point of 3.8 mm; confirm point geometry against IFU |
| B. Braun | DAFILON® – black monofilament polyamide, USP 10/0 (EP 0.2), 15 cm, DRm5 micro-needle ⅜ circle round body of 5.0 mm | G1118110 (verified in official B. Braun catalogue) | Comparable by category | Same gauge, colour and length (15 cm); conical micro-needle of 5.0 mm compared to 3.8 mm; confirm exact point geometry against IFU |
| Luxsutures / LUXAMID | Luxamid Nylon Monofilament, USP 10/0, black, 15 cm, 3/8 circle micro taper needle of 3.8 mm | NY10MDR038-100 (verified in specialised distributor) | Functional equivalence by specifications, not interchangeable 1:1 | Very close configuration: same gauge, colour, length and needle of 3.8 mm; confirm finish and regulatory classification in the manufacturer’s official data sheet |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; the comparisons with ETHILON®, DAFILON® and LUXAMID are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution. This needle geometry (DR 3.8 taper point, USP 10/0, 15 cm) is only safely interchangeable within the Premisut system itself. Consult the technical department of Cahnos to validate any equivalence.
5. Selection tips and variants of interest
Tissue to suture: the USP 10/0 gauge (EP 0.2) is a thread of maximum fineness, indicated for approximation of very delicate soft tissues, ligatures, ophthalmology and neurosurgery. The DR needle with taper point separates fibres without cutting them, ideal for lax, vascular and well-irrigated structures; for planes requiring firmer penetration (skin, fascia), consider triangular point profiles from the same Premisut Prime range.
Gauge: with the same DR 3.8 needle, it is available in USP 9/0 (AMP649DR3,890) and USP 11/0 (AMP649DR3.8110). If you prefer a bit more strength while keeping USP 10/0, there are longer needles, such as the DR 5.1 (AMP649DR5.1100) and the DR 6.5 (AMP649DR6.5100).
Presentation: for continuous techniques or double anchoring with the same 10/0 gauge and 6.5 mm needle, it is available in the double-needle version 2×DR 6.5 on 30 cm thread (AMP644DR6.5100-2).
Material alternatives: if the protocol prefers a polyolefin over polyamide, the Premisut Prime range offers polypropylene with a DR needle in fine gauges (e.g. AMP739DR3.8100). Unifying supplier across the entire permanent suture portfolio enables B2B volume conditions.
Sterility verification: product sterilised by ethylene oxide and single-use; check the blister integrity and expiry date before each use and keep the reference P649DR3.8100 and batch number for traceability in the operating theatre and in the event of a claim. For annual contracts, tenders or hospital supply agreements, contact the technical-commercial team at Cahnos.