Description
1. Commercial Introduction
The NYLON Suture PREMISUT Prime is the reference of the premium range of non-absorbable sutures from Cahnos for procedures requiring precision, clean passage and minimal tissue damage. This configuration combines a nylon monofilament thread (polyamide 6 or 6.6), black, USP gauge 3/0 and 45 cm length, with a ½ circular needle with a triangular point of extra-long precision reverse cutting and square body of 22 mm (XHS 22 Prime profile).
It is the usual choice in ophthalmology, neurosurgery, plastic and cosmetic surgery, dermatology and general surgery services, as well as for purchasing centres and tenders seeking a high-performance permanent thread with predictable clinical behaviour and full traceability. Sterile product, ready to use, presented in a box of 12 units in individual sachets.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely: it gradually becomes encapsulated by fibrous connective tissue and retains high tensile strength for more than three months, comfortably covering the critical healing phase. Being an uncoated monofilament with a non-grooved surface, the thread slides easily through tissues, without wicking effect, reduces bacterial drag compared to multifilaments and minimises the inflammatory reaction, an essential behaviour in cosmetic sutures and delicate planes.
The XHS 22 Prime needle features a ½ circle curvature with a precision extra-long reverse cutting triangular point (Reverse Extra Cutting) and square body: the cutting edge, with a long cutting edge, cuts in the opposite direction to the wound bed, generating a clean entry hole that preserves the skin edge and prevents the cut from widening, while the square body optimises grip in the needle holder and torque transmission. The USP 3/0 gauge (metric EP 2) offers the optimal balance between manageability and strength for medium suture tissues, and the 45 cm of thread provides sufficient length for interrupted sutures or contained surgical fields. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the distributor (Cahnos S.L.).
3.1. General characteristics
| Parameter | Specification |
| Brand / Quality | PREMISUT Prime (premium range) |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament, smooth non-grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / Size | USP 3/0 (metric EP 2), in accordance with USP and European Pharmacopoeia gauges. |
| Approximate thread diameter | 0.20 – 0.249 mm |
| Thread length | 45 cm (free end, without loop) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | ½ circle (1/2 circle) |
| Tip type | Triangular extra-long precision reverse cutting (Reverse Extra Cutting, long cutting edge) |
| Needle body | Square (maximum stability in the needle holder) |
| Needle size | 22 mm (XHS 22 Prime profile) |
| Configuration | 1 needle per unit, single armed, non-grooved |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology, neurosurgery, plastic and cosmetic surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P641XHS2230 |
| Reference Cahnos (SKU) | AMP641XHS2230 |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 3/0 (this product) | 2 | 0.20 – 0.249 mm |
3.3. PREMISUT Prime XHS family (½ circle needle, triangular point extra-long precision reverse cutting, square body)
| Needle profile | USP size | Thread | Reference |
| XHS 8 Prime | 8/0 | 1 × 45 cm (black) | P641XHS880 / AMP641XHS880 |
| XHS 13 Prime | 5/0 | 1 × 45 cm (black) | P641XHS1350 / AMP641XHS1350 |
| XHS 17 Prime | 5/0 | 1 × 75 cm (black) | P642XHS1750 / AMP642XHS1750 |
| XHS 22 Prime | 3/0 | 1 × 45 cm (black) | P641XHS2230 / AMP641XHS2230 (this product) |
| XHS 48 Prime | 1 | 1 × 100 cm (black) | P647XHS4810 / AMP647XHS4810 |
4. Equivalences and Cross-References
The reference P641XHS2230 corresponds to the official nomenclature of the Premisut Prime range (XHS 22 profile: ½ circle needle with extra-long precision reverse cutting triangular point with 22 mm square body, USP 3/0 gauge, 45 cm black thread) and Cahnos markets it without altering characters: no digit should be added, removed or reordered when ordering or bidding. Black non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercial type «Ethilon»). There is no manufacturer-validated equivalence table cross-referencing this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (J&J MedTech) | ETHILON® – black nylon monofilament, 3-0, 45 cm (18″), X-1 needle of 22 mm, ½ circle, reverse cutting | 642G (verified in official Ethicon EPC/EMEA catalogue and authorised distribution) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6/6.6), gauge 3/0 (EP 2), black colour, length 45 cm, ½ circle curvature, reverse cutting point family and needle size of 22 mm; the sharpening geometry differs: standard reverse cutting X-1 versus XHS 22 Prime with extra-long precision edge and square body. Usual presentation in box of 12 or 36; verify IFU before substituting. |
Other homologous families in the segment that must be reviewed property by property (material, gauge, ½ circle curvature, reverse cutting point family, needle length of 22 mm within tolerance ±1 mm, thread length of 45 cm, black colour, single needle arming and CE/MDR regulatory classification) before any substitution: DAFILON® (B. Braun, polyamide monofilament), MONOSOF™ and DERMALON™ (Medtronic/Covidien), DemeLON™ (DemeTECH), LUXAMID® (LuxSutures) and the polyamide ranges from Serag-Wiessner. No code from these companies has been found in public sources (GUDID/EUDAMED and official catalogues) that reproduces the exact combination XHS 22 Prime + USP 3/0 + 45 cm black thread with extra-long edge and square body, so no third-party cross-reference codes are published without verification. The cited brands belong to their respective manufacturers and are mentioned solely as equivalence reference. This needle geometry (XHS 22 Prime, USP 3/0, 45 cm thread) is only fully safely interchangeable within the Premisut system itself. There is no manufacturer-validated equivalence table; consult the technical department before use in tendering.
5. Selection tips and variants of interest
- Tissue to suture: the USP 3/0 (EP 2) gauge offers the optimal balance between fineness and strength for skin, subcutaneous tissue, mucous membranes and soft tissues under medium tension. The extra-long reverse-cutting XHS 22 Prime needle with square body penetrates firm, non-distensible tissues by separating the fibres without tearing the puncture bed, being especially indicated in plastic, cosmetic and ophthalmic surgery; for finer planes consider the 4/0 or 5/0 from the same family.
- Needle length: the XHS 22 mm profile is the intermediate size in the Prime precision family. For reduced fields or superficial planes, the same XHS Prime family offers 8, 13 and 17 mm profiles (P641XHS880, P641XHS1350 and P642XHS1750); for wide access or deep planes, the XHS 48 mm profile (P647XHS4810).
- Portfolio unification: the XHS Prime family allows supplier unification across the entire range of non-absorbable precision sutures with extra-long reverse-cutting ½ circle needle. If the protocol allows another curvature, the range offers XDS profiles (⅜ circle, precision reverse-cutting) for more superficial access applications with the same cosmetic result.
- Presentations: this reference is supplied in a box of 12 units in individual sterile sachets with batch traceability, the usual format for operating theatre, purchasing centres and tenders. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team at Cahnos.
- Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P641XHS2230 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.