Description
1. Commercial Introduction
The NYLON Suture PREMISUT 1/2 Cylindrical HR40 (factory ref. 645HR40L01 · SKU AM645HR40L01) is the reference in the standard range from Cahnos within non-absorbable nylon sutures for procedures requiring a permanent, high-strength thread. It combines a polyamide 6 or 6.6 monofilament, identifying black colour, USP 1 gauge and 150 cm of grooved thread in a loop presentation, mounted on a ½-circle needle with cylindrical body and taperpoint conical tip of 40 mm (HR40 profile).
It is a common choice in ophthalmology, neurosurgery, general surgery services and in purchasing and tendering centres that need a permanent suture with predictable clinical behaviour and full traceability. Sterile, ready-to-use product, supplied in a box of 12 units in individual sachets.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely. It gradually becomes encapsulated by connective tissue and maintains high tensile strength for more than three months, comfortably covering the critical healing phase. Being an uncoated monofilament, the strand slides easily through tissues, reduces the wicking effect and bacterial drag compared with multifilament sutures, and minimises the inflammatory reaction. The grooved surface finish improves knot retention and handling.
The HR40 needle of 40 mm features a ½-circle curvature with a cylindrical body and conical (taperpoint) tip: the sharp tip without cutting edges passes through tissues by separating the fibres without cutting them, making it especially suitable for soft, well-vascularised tissues (fascia, peritoneum, muscle, conjunctiva). The USP 1 gauge (metric EP 4) provides high tensile strength, and the 150 cm of looped thread allows continuous sutures or multiple ligatures without the need to re-thread the needle. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / Quality | PREMISUT (standard line) |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 1 (metric EP 4); conforms to USP and European Pharmacopoeia gauges |
| Approximate thread diameter | 0.40 – 0.499 mm (according to USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 150 cm in loop (loop) |
| Thread colour | Identifying black, grooved (high visibility on the surgical field) |
| Needle shape | ½ circle (½ circular), cylindrical body |
| Tip type | Conical / cylindrical (Taperpoint) |
| Needle size | HR 40 (40 mm) |
| Configuration | 1 needle per unit, 150 cm thread in loop (loop 1) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Storage | Below 30 °C, away from moisture and direct sunlight |
| Factory reference | 645HR40L01 |
| Reference Cahnos (SKU) | AM645HR40L01 |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
3.3. Family PREMISUT HR40 (½-circle needle, 40 mm, taperpoint conical tip, black thread)
| Needle profile | USP size | Thread | Reference |
| HR40 (standard) | 1 | 1 × 150 cm loop (black) | 645HR40L01 / AM645HR40L01 (this product) |
| HR40 Prime | 1 | 1 × 150 cm loop (black) | P645HR40L01 / AMP645HR40L01 |
| HR40 (standard) | 0 | 1 × 150 cm loop (black) | 645HR40L10 / AM645HR40L10 |
| HR40 Prime | 0 | 1 × 150 cm loop (black) | P645HR40L10 / AMP645HR40L10 |
| HR30 (standard) | 1 | 1 × 150 cm loop (black) | 645HR30L01 / AM645HR30L01 |
| HR50 (standard) | 1 | 1 × 150 cm loop (black) | 645HR50L01 / AM645HR50L01 |
The 645 series corresponds to 150 cm thread with loop; the 642 series, to 75 cm thread; the 643 series, to 90 cm thread without loop. The same 40 mm needle is available in USP gauges 0, 1 and 2 within the PREMISUT system.
4. Equivalences and Cross-References
The reference 645HR40L01 corresponds to the official nomenclature of the PREMISUT range (HR40 profile: ½-circle needle with cylindrical body and 40 mm taperpoint conical tip, USP 1 gauge, black 150 cm looped grooved thread) and Cahnos markets it without altering characters: no digit should be added, removed or reordered when ordering or tendering. Black non-absorbable monofilament nylon is one of the most standardised permanent suture families on the market (commercially type «Ethilon»). There is no manufacturer-validated equivalence table cross-referencing this reference with other brands for the exact combination USP 1 + ½-circle taperpoint needle of 40 mm + black 150 cm looped thread. References have been found in official sources (Ethicon EMEA catalogue, DemeTECH official store and GUDID) that match in material, gauge, colour and loop configuration, with differences in needle size:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Ethicon (Johnson & Johnson) | ETHILON® – black monofilament nylon, USP 1 (EP 4), 150 cm looped, CTX ½-circle needle with conical (taperpoint) tip, 48 mm | W748 (verified in official Ethicon EMEA catalogue and authorised distribution) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6), USP 1 gauge (EP 4), black colour, ½-circle curvature, conical tip family and 150 cm looped thread. The needle size differs: CTX 48 mm versus HR40 of 40 mm (outside the ±1 mm tolerance). Confirm the technical data sheet or IFU before any substitution. |
| DemeTECH | DemeLON® – black monofilament nylon, USP 1, 150 cm looped, DCTX LOOP ½-circle needle with conical (taperpoint) tip, 48 mm | NL560148BI1P (verified in DemeTECH official store and GUDID) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6), USP 1 gauge, black colour, loop configuration, ½-circle curvature and conical tip family. The needle size differs: 48 mm versus 40 mm (outside the ±1 mm tolerance). Confirm IFU and regulatory classification before substituting. |
Homologous market families that must be reviewed property by property (material, gauge, curvature, tip family, needle and thread length, colour and CE/MDR regulatory classification) before any substitution: Ethicon ETHILON™, B. Braun Dafilon®, Medtronic Monosof™/Dermalon™, SMI SUPRAMID, LuxSutures Luxamid and DemeTECH DemeLON. No codes from these manufacturers have been verified in public sources for the exact HR40 configuration of 40 mm, USP 1 and black 150 cm looped thread; they must be confirmed with the manufacturer before use in substitution or tendering. There is no manufacturer-validated equivalence table; consult the technical department before use in tendering. This needle geometry (HR40, USP 1, 150 cm looped) is only interchangeable with full safety within the PREMISUT system itself.
5. Selection tips and variants of interest
- Tissue to suture: the USP 1 gauge (EP 4) offers high tensile strength for subcutaneous tissue, fascia, aponeurosis and soft tissues under high tension, always with a conical tip needle to minimise tissue damage. For finer planes, consider the USP 0 of the same geometry (Ref. AM645HR40L10).
- Needle length: the HR40 profile of 40 mm covers medium-depth accesses. For smaller fields, the HR30 (Ref. AM645HR30L01) and HR35 (Ref. AM645HR35L01) are available; for deeper accesses, the HR50 (Ref. AM645HR50L01), all in USP 1 with a 150 cm loop.
- Thread presentation: this product is supplied as a 150 cm loop, practical for ligatures, continuous sutures and deep-field surgery without re-threading. The same HR40 needle is available with 75 cm (series 642) and 90 cm (series 643) thread.
- Prime quality: if the procedure requires maximum lot-to-lot sharpness consistency, the exact same configuration in the Prime range corresponds to Ref. P645HR40L01 (SKU AMP645HR40L01), a direct equivalent within the same manufacturer.
- Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use, and keep the reference 645HR40L01 and the lot number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.
For special B2B volume conditions, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.