Description
1. Product Presentation
At Cahnos we offer you the non-absorbable nylon monofilament suture from the PREMISUT Prime range, factory reference P642HR4020.2 (SKU AMP642HR4020.2), in a presentation of 2 strands of 75 cm per pack. This configuration incorporates a needle of ½ circle with cylindrical body and taper point of 40 mm (HR 40 Prime profile) on a black strand of USP 2/0 gauge: the reference combination for approximation of soft tissues, ligatures and precision specialties such as ophthalmology and neurosurgery. Prime quality provides an improved surface finish that optimises passage through tissue and knot security, with predictable behaviour and special conditions for hospital supply, tenders and volume contracts. Sold in boxes of 12 units.
2. Technical explanation of the material and procedure
The suture is manufactured in nylon (polyamide 6 or 6.6) in a monofilament configuration: a single continuous, smooth and uncoated filament that minimises microorganism adherence, the sawing effect on tissue and the inflammatory reaction. Being non-absorbable, it permanently maintains its structural integrity and provides a gradual encapsulation with high tensile strength, helping to support the wound for more than three months and comfortably covering the critical healing phase. The grooved finish of the strand improves knot grip and the black colour guarantees optimal contrast on the surgical field.
The HR 40 Prime needle of ½ circle has a cylindrical body and taper point (taperpoint): the rounded point passes through the tissue separating the fibres rather than cutting them, making it especially suitable for soft, lax and well-irrigated tissues, vascular walls, ligatures and precision approximations in ophthalmology and neurosurgery. The 2×75 cm presentation incorporates two strands per unit, practical for continuous or multi-point suture techniques. Sterilisation by ethylene oxide (EO) ensures its sterile delivery, ready for immediate use; it is a single-use product and does not allow re-sterilisation.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Factory reference | P642HR4020.2 (suffix .2 = double strand 2×75 cm) |
| SKU Cahnos | AMP642HR4020.2 |
| Brand / Quality | PREMISUT Prime (premium range) |
| Material | Nylon monofilament (polyamide 6 / 6.6), uncoated |
| Thread structure | Monofilament, grooved finish |
| Gauge / USP size | USP 2/0 (metric 3 / EP 3) |
| Approximate thread diameter | 0.30 – 0.339 mm (USP Pharmacopoeia) |
| Thread length | 2 × 75 cm (two strands per pack, 1 needle per strand) |
| Thread colour | Black (high visibility in surgical field) |
| Needle shape | ½ circle (1/2 circular), grooved |
| Tip type | Conical (Taperpoint), cylindrical body |
| Needle size | 40 mm (HR 40 Prime model) |
| Swaged | 1 needle per suture (2 needles per pack) |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
3.2. Gauge equivalence (non-absorbable suture, USP/EP Pharmacopoeia)
| USP size | Metric measurement (EP) | Approximate diameter |
|---|---|---|
| 2/0 | 3 | 0.30 – 0.339 mm |
The diameter of the strand complies with the official ranges of the USP Pharmacopoeia for non-absorbable sutures, without exceeding its limits.
3.3. HR 40 Prime family (½-circle 40 mm needle, taper point, black thread)
| Needle profile | USP size | Thread | Reference |
|---|---|---|---|
| HR 40 Prime | 2/0 | 2 × 75 cm | P642HR4020.2 / AMP642HR4020.2 (this product) |
4. Equivalences and Cross-References
Non-absorbable nylon monofilament is one of the most standardised permanent suture families in the surgical market for approximation of soft tissues and ligatures. There is no equivalence table validated by the manufacturer that cross-references this specific configuration (½ circle taper point needle HR 40 mm, USP 2/0 gauge, black, double strand 2×75 cm) with references from other brands; therefore, the following matches are functional comparisons and should not be treated as 1:1 interchangeable without prior technical validation and confirmation of the strand presentation. The cited codes have been checked against the manufacturer’s official catalogue.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| B. Braun (Aesculap) | DAFILON, uncoated polyamide monofilament | C0930474 (USP 2/0, blue, 75 cm, HR30 ½-circle needle, round body / taper point) | Comparable by category (not interchangeable 1:1) | Code confirmed in the official catalogue of B. Braun. They match in material (polyamide 6/6.6), USP 2/0 gauge (EP 3), strand length (75 cm), ½ circle curvature and round body taper point family; they differ in strand colour (blue vs. black), needle size (30 mm vs. 40 mm) and presentation (1 strand vs. 2×75 cm). The black version of Dafilon (polyamide 6.6, ophthalmology/microsurgery) exists, but its code is not verified in public sources; confirm with the manufacturer. |
| B. Braun (Aesculap) | DAFILON, uncoated polyamide monofilament | C0930423 (USP 2/0, blue, 75 cm, HR26 ½-circle needle, round body / taper point) | Comparable by category (not interchangeable 1:1) | Code confirmed in the official catalogue of B. Braun. Same material, gauge and strand length; taper point needle in ½ circle of 26 mm vs. the HR 40 of 40 mm. They differ in colour and presentation. |
Other homologous families of non-absorbable nylon monofilament with round/taper point needles in ½ circle —such as Ethicon ETHILON (Johnson \u0026 Johnson MedTech), Medtronic Monosof, Serag-Wiessner SERALON or DemeTECH DemeLON— appear in public sources with needles of different sizes and lengths from this configuration; they must be verified property by property (material, gauge, curvature, point family, needle size, length and number of strands, colour and regulatory classification CE/MDR) in their official technical data sheets and GUDID/EUDAMED before any substitution.
There is no equivalence table validated by the manufacturer for this configuration (HR 40 mm taper point needle, USP 2/0, black, 2×75 cm); consult the technical-commercial department of Cahnos before use in tenders. Before any formal substitution, verify in the technical data sheet or IFU of the alternative manufacturer the exact gauge, strand length and its number of strands per pack, needle geometry and size, colour, surface treatment and regulatory classification (CE/MDR). This needle geometry (HR 40, USP 2/0) is only interchangeable with complete safety within the Premisut system itself. The cited brands belong to their respective manufacturers and are mentioned solely as an equivalence reference.
5. Selection tips and variants of interest
Tissue to suture: the HR needle with conical point (cylindrical body) is indicated for lax, well-vascularised soft tissues and vascular planes, as well as for ligatures and precise approximation in ophthalmology and neurosurgery; for skin, mucous membranes and firm tissues, consider the reverse cutting profiles (DS/HS series) from the same range. Gauge: USP 2/0 (metric 3) offers an optimal balance between strength and handling for subcutaneous tissue and soft tissues under moderate tension; for finer planes consider 3/0 and for higher loads USP 0 from the same HR family. Presentation: this reference provides 2 threads of 75 cm per pack, ideal for high-consumption surgical programmes; if the protocol requires a single thread, the same needle and gauge are available in a 1×75 cm presentation.
Variants of interest within the Cahnos catalogue: AMP642HR2020 (HR 20 Prime, USP 2/0, black, 1×75 cm), AMP642HR2020.2 (HR 20 Prime, USP 2/0, black, 2×75 cm), 642HR2620 (HR 26, USP 2/0, black, 75 cm), as well as the double-thread family with reverse cutting needle AMP642DS2620.2 and AMP642DS2420.2 for skin and firm tissues.
As this is a sterile single-use product, check the integrity of the blister and the expiry date before each procedure, and keep the reference P642HR4020.2 together with the batch number for traceability in the operating theatre. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.