Description
1. Commercial Introduction
The NYLON PREMISUT Prime 1/2 Round-bodied HR50mm Suture is the Prime range reference for procedures requiring a high-performance permanent suture mounted on a medium-bodied needle with a tapered point. It combines a black-identifying nylon (polyamide 6 or 6.6) monofilament, USP 0 gauge and 150 cm of fluted looped suture, with a ½-circle 50 mm Taperpoint tapered-point needle (HR50 profile).
It is a common choice in general surgery, ophthalmology, neurosurgery departments and in purchasing and tendering centres that require a permanent suture with predictable clinical performance and full batch traceability. The Prime quality provides superior sharpening precision and batch-to-batch consistency, with the same needle profile and gauge as the standard range.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in tissue indefinitely, gradually encapsulating and maintaining high tensile strength for over three months, comfortably covering the critical healing phase. As an uncoated monofilament, the thread slides easily through tissues, reduces the wicking effect and bacterial drag compared to multifilaments, and minimises inflammatory reaction. The fluted finish of the strand improves knot retention and handling.
The 50 mm HR50 needle features a ½-circle (1/2 circular) curvature with a cylindrical body and Taperpoint tapered point: it does not cut but separates tissue fibres, making it ideal for soft tissues, fascia, peritoneum, muscle and well-vascularised structures. USP 0 gauge (metric EP 3.5) offers an optimal balance between strength and low trauma, and the 150 cm loop (loop) format allows continuous sutures over long distances without rethreading the needle and facilitates anchoring the thread in the needle holder. Sterilisation by ethylene oxide (EO); single-use product, not for resterilisation.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / quality | PREMISUT Prime |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / size | USP 0 (metric EP 3.5), conforming to USP and European Pharmacopoeia gauges |
| Approximate thread diameter | 0.35 – 0.399 mm |
| Thread length | 150 cm (looped end / loop) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | 1/2 circle (½ circular), cylindrical body |
| Tip type | Conical Taperpoint (conical point, non-cutting) |
| Needle size | HR 50 (50 mm) |
| Configuration | 1 needle per unit, grooved thread with loop |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P645HR50L10 |
| Reference Cahnos (SKU) | AMP645HR50L10 |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
| 2 | 5 | 0.45 – 0.499 mm |
3.3. PREMISUT HR50 family (½ circle needle, 50 mm, Taperpoint conical point, black grooved suture)
| Needle profile | USP size | Thread | Reference |
| HR 50 | 0 | 1 × 150 cm with loop (black, standard range) | 645HR50L10 / AM645HR50L10 |
| HR 50 | 1 | 1 × 90 cm (black, standard range) | 643HR5001 / AM643HR5001 |
| HR 50 | 1 | 1 × 150 cm with loop (black, standard range) | 645HR50L01 / AM645HR50L01 |
| HR 50 | 2 | 1 × 150 cm with loop (black, standard range) | 645HR50L02 / AM645HR50L02 |
| HR 50 Prime | 0 | 1 × 150 cm with loop (black, Prime range) | P645HR50L10 / AMP645HR50L10 (this product) |
| HR 50 Prime | 1 | 1 × 90 cm (black, Prime range) | P643HR5001 / AMP643HR5001 |
| HR 50 Prime | 1 | 1 × 150 cm with loop (black, Prime range) | P645HR50L01 / AMP645HR50L01 |
The 645 series corresponds to 150 cm thread with loop; the 643 series to 90 cm thread without loop. The same 50 mm needle is available in USP 0, 1 and 2 gauges within the PREMISUT system.
4. Equivalences and Cross-References
The reference P645HR50L10 corresponds to the official nomenclature of the PREMISUT range (HR50 profile: ½-circle Taperpoint tapered-point needle 50 mm, USP 0 gauge, black thread 150 cm with loop, fluted) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering.
Black non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercial type “Ethilon”). However, there is no manufacturer-validated equivalence table cross-referencing this item with other brands for the exact combination of USP 0 + ½-circle 50 mm tapered-point needle + black 150 cm looped strand. The usual market practice for this configuration uses 48 mm taper needles (CT/DCT/CTX and similar), which fall outside the ±1 mm tolerance compared to the 50 mm HR50; therefore, the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution:
- ETHILON® (Ethicon / J&J MedTech) – black nylon monofilament, USP 0, 150 cm, 48 mm ½-circle CT taper point needle. Reference consulted: W740G (code verified in Ethicon EMEA catalogue and authorised distribution). Comparable by category (not interchangeable 1:1): material, USP 0 gauge, colour, ½-circle curvature, tapered point family and strand length match; needle measurement differs (48 mm vs 50 mm, out of tolerance). Confirm IFU and CE/MDR classification before substituting.
- DemeLON™ (DemeTECH) – black nylon monofilament, USP 0, 150 cm with loop, ½-circle DCT LOOP needle with cylindrical body. Reference consulted: NL560040BI0P (verified on DemeTECH official store and GUDID). Comparable by category (not interchangeable 1:1): material, gauge, colour, loop configuration and curvature match; needle measurement differs (48 mm vs 50 mm, out of tolerance). Confirm IFU and regulatory classification before substituting.
Other homologous families on the market that must be checked property by property (material, gauge, curvature, point family, needle and strand length, presence of loop, colour and CE/MDR classification) before any substitution: DAFILON® (B. Braun / Aesculap), Monosof™ / Dermalon™ (Medtronic), LUXAMID® (LuxSutures) and SUPRAMID® (SMI / B. Braun). No codes from these companies for the exact HR50 50 mm configuration, USP 0 and black 150 cm looped strand have been verified in public sources; they must be confirmed with the manufacturer before use in substitution or tendering.
There is no manufacturer-validated equivalence table; consult the technical department before using in tendering. This needle geometry (HR50, USP 0, 150 cm with loop) is only safely interchangeable within the PREMISUT system itself.
5. Selection tips and variants of interest
- Tissue to suture: USP 0 gauge (EP 3.5) is the usual choice for subcutaneous tissue, fascia, peritoneum, muscle and approximation of soft tissues with medium tension. The tapered point separates fibres without cutting, minimising bleeding from the puncture site.
- Loop format: the 150 cm with loop (loop) facilitates continuous suturing over long distances and the thread anchoring manoeuvre, reducing the opening of pouches per procedure.
- Variants of the same HR50 profile: if the procedure requires USP 1 gauge in 150 cm with loop, the Prime version (SKU AMP645HR50L01) and standard (AM645HR50L01) are available; for USP 2 gauge, the standard AM645HR50L02; and for 90 cm thread without loop in USP 1, references AMP643HR5001 (Prime) and AM643HR5001 (standard).
- Equivalent standard range: the exact same configuration in the standard range (non-Prime) corresponds to Ref. 645HR50L10 (SKU AM645HR50L10), a direct equivalent within the same manufacturer.
- Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P645HR50L10 and the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.





Reviews