We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

NYLON Suture PREMISUT Prime 1/2 Circle Cylindrical Conical Taperpoint Tip HR40 (40 mm) – USP 0 (EP 3.5) – Black Non-Absorbable Monofilament 150 cm Loop – Box of 12 units (Ref. P645HR40L10 · SKU AMP645HR40L10)

15,93 €

NYLON Suture PREMISUT Prime 1/2 Cylindrical HR40: non-absorbable monofilament of polyamide 6/6.6, black grooved, gauge USP 0 (metric EP 3.5) and 150 cm of thread with loop. It mounts a Prime needle of ½ circle with cylindrical body and conical taperpoint tip of 40 mm (HR40 profile), ideal for approximation of soft tissues, ligatures, ophthalmology and neurosurgery. Sterilised by ethylene oxide, single-use. Presentation: box of 12 units in individual sachets with batch traceability. Factory ref. P645HR40L10 · SKU AMP645HR40L10.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP645HR40L10

Description

1. Commercial Introduction

The Suture NYLON PREMISUT Prime 1/2 Cylindrical HR40 (Factory ref. P645HR40L10 · SKU AMP645HR40L10) is the premium reference from Cahnos within non-absorbable nylon sutures for procedures requiring a permanent high-performance thread. It combines a polyamide 6 or 6.6 monofilament, identifying black colour, USP 0 gauge and 150 cm of grooved thread in a loop presentation, mounted on a Prime needle of ½ circle with cylindrical body and taperpoint conical point of 40 mm (HR40 profile).

Prime quality guarantees consistent sharpness batch after batch and predictable penetration in each stitch, being especially valued in ophthalmology, neurosurgery and general surgery departments, as well as in purchasing centres that need a permanent thread with full traceability. Sterile product, ready to use, presented in a box of 12 units in individual sachets.

2. Technical Explanation

Nylon (polyamide 6 or 6.6) is a synthetic polymer non-absorbable that remains in the tissue indefinitely. It gradually becomes encapsulated by connective tissue and maintains high tensile strength for more than three months, comfortably covering the critical healing phase. Being a uncoated monofilament, the strand slides easily through tissues, reduces the wick effect and bacterial drag compared to multifilaments, and minimises the inflammatory reaction. The grooved surface finish improves knot retention and handling.

The 40 mm HR40 Prime needle features a ½ circle curvature with cylindrical body and conical point (taperpoint): the sharp point without cutting edges passes through tissues separating the fibres without cutting them, making it especially suitable for soft and well-vascularised tissues (fascia, peritoneum, muscle, conjunctiva). The 150 cm loop format allows continuous sutures or multiple ligatures without the need to re-thread the needle. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.

3. Technical specifications and tables

3.1. General characteristics

Parameter Specification
Brand / Quality PREMISUT Prime (premium range)
Thread material Nylon monofilament (polyamide 6 or 6.6), uncoated
Thread structure Monofilament with grooved surface
Absorption Non-absorbable; gradual encapsulation, wound support for more than 3 months
Gauge / USP size USP 0 (metric EP 3.5); conforming to USP and European Pharmacopoeia gauges
Approximate thread diameter 0.35 – 0.399 mm (according to USP Pharmacopoeia, non-absorbable suture)
Thread length 150 cm in loop (loop)
Thread colour Identifying black, grooved (high visibility on the surgical field)
Needle shape ½ circle (½ circular), cylindrical body
Tip type Conical / cylindrical (Taperpoint)
Needle size HR 40 Prime (40 mm)
Configuration 1 needle per unit, 150 cm thread in loop (loop 0)
Sterilisation Ethylene oxide (EO) – sterile
Use Single-use, sterile. Do not re-sterilise
Indications Approximation of soft tissues, ligatures, ophthalmology and neurosurgery
Commercial presentation Box of 12 units (sterile individual sachets); batch traceability
Storage Below 30 °C, away from moisture and direct sunlight
Factory reference P645HR40L10
Reference Cahnos (SKU) AMP645HR40L10

3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
0 3.5 0.35 – 0.399 mm
1 4 0.40 – 0.499 mm

3.3. Family PREMISUT HR40 (1/2 circle needle, 40 mm, taperpoint conical point, black thread)

Needle profile USP size Thread Reference
HR40 Prime 0 1 × 150 cm loop (black) P645HR40L10 / AMP645HR40L10 (this product)
HR40 Prime 1 1 × 150 cm loop (black) P645HR40L01 / AMP645HR40L01
HR40 (standard range) 0 1 × 150 cm loop (black) 645HR40L10 / AM645HR40L10
HR40 Prime 0 2 × 75 cm (black) P642HR4010.2
HR30 Prime 0 1 × 150 cm loop (black) P645HR30L10 / AMP645HR30L10
HR50 Prime 0 1 × 150 cm loop (black) P645HR50L10 / AMP645HR50L10

4. Equivalences and Cross-References

Reference P645HR40L10 corresponds to the official nomenclature of the PREMISUT Prime range (HR40 profile: ½ circle needle with cylindrical body and taperpoint conical point of 40 mm, USP 0 gauge, black 150 cm looped grooved thread) and Cahnos markets it without altering characters: no digit should be added, removed or reordered when ordering or bidding. Black non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercially type «Ethilon»).

There is no manufacturer-validated equivalence table cross-referencing this reference with other brands for the exact combination of USP 0 + ½ circle taperpoint needle of 40 mm + black 150 cm looped strand. A reference has been located in the official Ethicon (EMEA) catalogue that matches in material, gauge and needle geometry, with differences only in thread length and format:

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Ethicon (Johnson & Johnson) ETHILON™ Nylon Suture – black monofilament, USP 0 (EP 3.5), 100 cm thread without loop, CT needle of ½ circle conical point (taperpoint) of 40 mm W746 (verified in official Ethicon EMEA catalogue and authorised distribution) Comparable by category (not interchangeable 1:1) They match in material (polyamide 6), USP 0 gauge (EP 3.5), black colour, ½ circle curvature and CT needle size of 40 mm (identical to HR40). The thread presentation differs: 100 cm without loop versus 150 cm with loop from PREMISUT. Confirm the technical data sheet or IFU before any substitution.

Homologous market families that must be reviewed property by property (material, gauge, curvature, point family, needle and strand length, colour and CE/MDR regulatory classification) before any substitution: Ethicon ETHILON™, B. Braun Dafilon®, Medtronic Monosof™/Dermalon™, SMI SUPRAMID, LuxSutures Luxamid and DemeTECH DemeLON. No codes from these manufacturers have been verified in public sources for the exact HR40 configuration of 40 mm, USP 0 and black 150 cm looped strand; they must be confirmed with the manufacturer before use in substitution or bidding.

There is no manufacturer-validated equivalence table for this configuration; check in the technical data sheet or instructions for use (IFU) of the alternative manufacturer the exact gauge, thread length, needle geometry and size, colour and regulatory classification (CE/MDR) before using this information in tenders or direct substitution. This needle geometry (HR40 Prime, USP 0, 150 cm loop) is only safely interchangeable within the PREMISUT system itself. Consult the technical department of Cahnos to validate any equivalence.

5. Selection tips and variants of interest

Tissue to suture: USP 0 gauge (EP 3.5) is ideal for approximating soft and subcutaneous tissue with medium tension, providing high tensile strength with minimal tissue reaction, always with a conical point needle to avoid cutting the fibres. For planes with higher tension, consider USP 1 of the same geometry (Ref. AMP645HR40L01).

Needle length: the 40 mm HR40 profile covers medium-depth accesses. For smaller fields, the HR30 and HR35 families of the same Prime range are available in USP 0 with 150 cm loop (Ref. AMP645HR30L10); for deeper accesses, the HR50 (Ref. AMP645HR50L10).

Presentation and thread length: this product is in a 150 cm loop, practical for ligatures, continuous sutures and deep-field surgery without re-threading. If you prefer 75 cm thread in double strand, the same HR40 Prime needle in USP 0 is available in the 642 series (Ref. P642HR4010.2).

Prime quality vs. standard: the Prime range offers maximum sharpness and batch-to-batch consistency. The same HR40 USP 0 configuration in a 150 cm loop is available in standard quality (Ref. AM645HR40L10), with identical dimensional specifications.

Sterility verification: product sterile by ethylene oxide and single-use; check the blister integrity and expiry date before each use, and keep the reference P645HR40L10 and batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.

For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Product line

PREMISUT Prime

Manufacturer reference

P645HR40L10

Material

Nylon monofilament (polyamide 6 or 6.6), uncoated

Structure

Monofilament with grooved surface

Coating

None

Absorption

Non-absorbable; gradual encapsulation, wound support for more than 3 months

USP size

USP 0 (metric EP 3.5)

Metric gauge (EP)

3.5

Thread diameter

0.35 – 0.399

Thread length

150 cm in loop (loop)

Needle shape

1/2 circle (½ circle)

Tip type

Conical / cylindrical (Taperpoint)

Needle size

HR 40 Prime (40 mm)

Configuration

1 needle per unit, loop 0, grooved thread

Sterilisation

Ethylene oxide (EO) – sterile

Use

Single-use, sterile. Do not re-sterilise

Presentation

Box of 12 units in individual sterile envelopes

Indications

Approximation of soft tissues, ligatures, ophthalmology and neurosurgery

Regulatory standard

Complies with USP/EP Pharmacopoeia; CE marking (MDR)

Medida de aguja

HR 40

Usp

0

Color

Black

Medida de hilo

150 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “NYLON Suture PREMISUT Prime 1/2 Circle Cylindrical Conical Taperpoint Tip HR40 (40 mm) – USP 0 (EP 3.5) – Black Non-Absorbable Monofilament 150 cm Loop – Box of 12 units (Ref. P645HR40L10 · SKU AMP645HR40L10)”

Your email address will not be published. Required fields are marked *