Description
1. Commercial Introduction
The Suture NYLON PREMISUT Prime in double-strand presentation (factory reference P642HR3010.2 · SKU Cahnos AMP642HR3010.2) is the premium reference from Cahnos within non-absorbable nylon sutures for procedures requiring maximum sharpness precision and batch-to-batch consistency. It combines a nylon monofilament (polyamide 6 or 6.6) in identifying black colour, USP size 0 (metric EP 3.5) and two 75 cm strands with needles, allowing suturing with ample length or distributing the material across two fields without re-swaging.
It is a common choice in ophthalmology, neurosurgery, general surgery departments and in purchasing and tendering centres that need a permanent thread with high performance, predictable clinical behaviour and complete batch traceability. Sterile, ready-to-use product, presented in a box of 12 individual sachets.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely, gradually encapsulating and maintaining high tensile strength for more than three months, comfortably covering the critical healing phase. Being an uncoated monofilament, the thread slides easily through tissues, reduces the wick effect and bacterial drag compared with multifilaments, and minimises the inflammatory reaction. The grooved finish of the strand improves knot retention and handling in the surgical field, while the black colour ensures optimal contrast on the operative field.
The 30 mm HR30 Prime needle features a ½ circle curvature with a cylindrical body and conical point (taperpoint): the sharp point without cutting edges passes through tissues by separating the fibres without cutting them, making it especially suitable for soft, well-vascularised tissues (fasciae, peritoneum, muscle, conjunctiva) where minimising trauma is sought. Prime quality ensures more consistent sharpening and more predictable penetration at each stitch. USP size 0 (metric EP 3.5) offers balanced strength for tissues under medium tension, and the 2 x 75 cm strand presentation provides the versatility needed for continuous sutures or multiple stitches. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical specifications and tables
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Brand / Quality | PREMISUT Prime (premium range) |
| Factory reference | P642HR3010.2 (suffix .2 = double thread 2×75 cm) |
| Reference Cahnos (SKU) | AMP642HR3010.2 |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament with grooved surface |
| Coating | None |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / Size | USP 0 (metric EP 3.5); conforms to USP/EP Pharmacopoeia |
| Approximate thread diameter | 0.35 – 0.399 mm |
| Thread length | 2 strands of 75 cm (2 × 75 cm, double thread) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | ½ circle (1/2 circular), cylindrical body |
| Tip type | Conical / Taperpoint, grooved |
| Needle size | HR 30 Prime (30 mm) |
| Configuration | 2 threads of 75 cm with needle (double presentation) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 sterile individual sachets; batch traceability |
| Regulatory standard | Complies with USP/EP Pharmacopoeia; CE marking (MDR) |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 2/0 | 3 | 0.30 – 0.339 mm |
| 0 (this product) | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
| 2 | 5 | 0.50 – 0.599 mm |
The thread diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without exceeding their limits.
3.3. Family PREMISUT HR30 Prime (needle ½ circle of 30 mm, conical taperpoint, black thread)
| Needle profile | USP size | Thread | Reference |
|---|---|---|---|
| HR 30 Prime | 1 | 1 × 75 cm (black) | P642HR3001 / AMP642HR3001 |
| HR 30 Prime | 1 | 2 × 75 cm (black, double thread) | P642HR3001.2 / AMP642HR3001.2 |
| HR 30 Prime | 0 | 1 × 75 cm (black) | P642HR3010 / AMP642HR3010 |
| HR 30 Prime | 0 | 2 × 75 cm (black, double thread) | P642HR3010.2 / AMP642HR3010.2 (this product) |
| HR 30 Prime | 2/0 | 1 × 75 cm (black) | P642HR3020 / AMP642HR3020 |
| HR 30 Prime | 2/0 | 2 × 75 cm (black, double thread) | P642HR3020.2 / AMP642HR3020.2 |
The same conical HR30 needle is available in other sizes (USP 1, 2/0) and in shorter needle profiles (HR20, HR26) or longer ones (HR37, HR40, HR50, series 643) depending on the surgical field reach.
4. Equivalences and Cross-References
The reference P642HR3010.2 corresponds to the official nomenclature of the PREMISUT Prime range (HR30 profile: ½ circle taperpoint conical-point needle of 30 mm, USP size 0, black grooved 75 cm thread, double-strand presentation) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering.
Non-absorbable black nylon monofilament is one of the most standardised permanent suture families on the market (commercial type ‘Ethilon’). There is no manufacturer-validated equivalence table cross-referencing this specific configuration (½ circle HR30 conical-point needle of 30 mm, USP 0, black, double strand 2×75 cm) with references from other manufacturers; therefore, the following match is a functional, category-level comparison, verified against the corresponding manufacturer’s official catalogue, and must not be treated as 1:1 interchangeable without prior technical validation.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| B. Braun (Aesculap) | DAFILON® – uncoated polyamide monofilament, USP 0 (EP 3.5), blue 75 cm thread, 30 mm HR30 needle (½ circle, round body, conical point) | C0930482 (verified in official B. Braun catalogue) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6/6.6), USP size 0 (EP 3.5), thread length (75 cm), ½ circle curvature, conical point family and needle size (identical 30 mm HR30); they differ in strand colour (blue vs. black) and presentation (1 thread vs. 2×75 cm). Confirm IFU and CE/MDR classification before substituting. |
Other homologous families on the market that must be reviewed property by property (material, size, curvature, point family, needle and strand length, colour and CE/MDR regulatory classification) before any substitution are: ETHILON® (Ethicon / Johnson & Johnson MedTech), Monosof™ and Dermalon™ (Medtronic / Covidien), DemeLON™ (DemeTECH), SERALON® (Serag-Wiessner), LUXAMID® (LuxSutures), SUPRAMID® (SMI) and Suturas Aragó (Laboratorio Aragó). No codes from these manufacturers have been verified in public sources for the exact HR30 30 mm, USP 0, conical point and black 75 cm strand in double presentation; they must be confirmed with the manufacturer before use in substitution or tendering.
There is no manufacturer-validated equivalence table for this configuration; check the technical data sheet or instructions for use (IFU) of the alternative manufacturer for the exact size, thread length and number of strands, needle geometry and size, colour and regulatory classification (CE/MDR) before using this information in tenders or direct substitution. This needle geometry (HR30 Prime, USP 0, double strand 2×75 cm) is only fully safely interchangeable within the PREMISUT system itself. Consult Cahnos’s technical department to validate any equivalence.
5. Selection tips and variants of interest
Tissue to suture: USP size 0 (metric EP 3.5) offers balanced strength for subcutaneous tissue, soft tissues, low-tension fasciae and ligatures, always with a conical-point needle to minimise tissue damage. For finer planes, consider USP 2/0 from the same HR30 Prime family (Ref. AMP642HR3020 or double version AMP642HR3020.2); for higher tension, USP 1 (Ref. AMP642HR3001 or double version AMP642HR3001.2).
Double presentation: this reference is a double thread 2×75 cm, ideal for continuous sutures without re-threading or to split the material across two surgical fields. If the protocol only requires one strand per package, the same geometry and gauge is available in a 1 × 75 cm presentation (Ref. AMP642HR3010).
Needle length: the 30 mm HR30 profile is the ideal choice for surgical fields with a medium-to-short reach. For even smaller accesses, the HR20/HR26 profiles from the same range are available, and for deeper fields, the HR37 (Ref. AMP642HR3710.2) and HR40 (Ref. AMP642HR4010.2) profiles with the same taper point family.
Prime vs. standard quality: if the procedure requires maximum sharpness precision and batch-to-batch consistency, the Prime range offers this same geometry and gauge; if the cost per unit is a critical factor, the standard range maintains the same dimensional specifications with standard sharpness performance.
Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister pack and the expiry date before each use, and keep the reference P642HR3010.2 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other manufacturers, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.