Description
1. Commercial Introduction
The NYLON PREMISUT Prime Suture (factory ref. P642HR2060 · SKU Cahnos AMP642HR2060) is the premium reference from Cahnos within non-absorbable nylon sutures for procedures requiring a permanent, manageable, high-performance thread, mounted on a cylindrical-bodied needle with a conical point. It combines a nylon monofilament (polyamide 6 or 6.6) in identifying black, USP gauge 6/0 (metric 0.7) and a smooth 75 cm uncoated strand, mounted on a Prime needle of ½ circle and taperpoint point of 20 mm (HR20 profile). It is a common choice in ophthalmology, neurosurgery, general surgery and purchasing departments that value batch-to-batch consistency and full traceability of the Prime range. Sterile product, ready to use, presented in a box of 12 individual pouches.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely, gradually encapsulating and maintaining high tensile strength for more than three months, comfortably covering the critical phase of healing. Being an uncoated, non-grooved monofilament, the thread slides easily through tissues, reduces the wick effect and bacterial drag compared with multifilaments, and minimises the inflammatory reaction. The black colour ensures optimal contrast on the surgical field. The 20 mm HR20 Prime needle features a ½ circle curvature with a cylindrical body and conical point (taperpoint): the sharp point without cutting edges passes through tissues by separating the fibres without cutting them, making it especially suitable for soft, well-vascularised tissues (fascia, peritoneum, muscle, conjunctiva) where minimising trauma is sought. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical specifications and tables
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Factory reference | P642HR2060 |
| Reference Cahnos (SKU) | AMP642HR2060 |
| Brand / Quality | PREMISUT Prime (premium range) |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament, smooth non-grooved surface |
| Coating | None |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / Size | USP 6/0 (metric EP 0.7); conforms to USP and European Pharmacopoeia sizes |
| Approximate thread diameter | 0.070 – 0.099 mm |
| Thread length | 75 cm (single strand, no loop) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | ½ circle (1/2 circular), cylindrical body |
| Tip type | Conical / Taperpoint |
| Needle size | HR 20 Prime (20 mm) |
| Configuration | 1 needle × 75 cm per pack |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 sterile individual sachets; batch traceability |
| Regulatory standard | Complies with USP/EP Pharmacopoeia; CE marking (MDR) |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 7/0 | 0.5 | 0.050 – 0.069 mm |
| 6/0 (this product) | 0.7 | 0.070 – 0.099 mm |
| 5/0 | 1 | 0.10 – 0.149 mm |
The thread diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without exceeding their established limits.
3.3. PREMISUT Prime family in nylon (½ circle needle, taperpoint conical point HR20, black thread)
| Needle profile | USP size | Thread | Reference |
|---|---|---|---|
| HR 20 Prime | 6/0 | 1 × 75 cm (black) | P642HR2060 / AMP642HR2060 (this product) |
| HR 20 Prime | 5/0 | 1 × 75 cm (black) | P642HR2050 / AMP642HR2050 |
| HR 20 Prime | 4/0 | 1 × 75 cm (black) | P642HR2040 / AMP642HR2040 |
| HR 20 Prime | 3/0 | 1 × 75 cm (black) | P642HR2030 / AMP642HR2030 |
| HR 20 Prime | 2/0 | 1 × 75 cm (black) | P642HR2020 / AMP642HR2020 |
| HR 20 standard | 6/0 | 1 × 75 cm (black) | 642HR2060 / AM642HR2060 |
The same conical needle is available in HR20 (shorter), HR26, HR30 and HR37 (longer travel) profiles and in USP gauges 6/0, 5/0, 4/0, 3/0, 2/0, 0 and 1 depending on the tissue plane to be sutured.
4. Equivalences and Cross-References
Reference P642HR2060 corresponds to the official nomenclature of the PREMISUT Prime range (HR20 profile: ½ circle needle with 20 mm taperpoint conical point, USP gauge 6/0, smooth black thread 75 cm) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering.
Black non-absorbable nylon monofilament is one of the most standardised permanent suture families in the surgical market (commercial type ‘Ethilon’). There is no manufacturer-validated equivalence table cross-referencing this specific configuration (½ circle needle with 20 mm HR20 conical point, USP gauge 6/0, black, 75 cm strand) with references from other manufacturers; therefore, the matches shown below are functional comparisons at category level, not interchangeable 1:1 without prior technical validation.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (J&J MedTech) | ETHILON® – black nylon monofilament, 6-0, 45 cm, P-3 needle 13 mm ⅜ circle, precision reverse cutting, pliable | 1698G | Comparable by category (not interchangeable 1:1) – code confirmed | Same material (polyamide), gauge 6/0 and black colour; differs in needle geometry (⅜ circle reverse cutting P-3 13 mm versus ½ circle taperpoint HR20 20 mm) and length (45 versus 75 cm). Verified in official Ethicon catalogue. |
| Ethicon (J&J MedTech) | ETHILON® – black monofilament nylon, 6-0, 45 cm, PS-4 needle 16 mm ½ circle, precision reverse cutting | 1662G | Comparable by category (not interchangeable 1:1) – code confirmed | The needle radius (½ circle) and gauge 6/0 match; the point differs (precision reverse cutting versus taperpoint conical), needle length (16 versus 20 mm) and strand (45 versus 75 cm). Verified in official Ethicon catalogue. |
There is no manufacturer-validated equivalence table; consult the technical department before use in tendering. This needle geometry (HR20 Prime, USP 6/0, 75 cm strand) is only fully safely interchangeable within the PREMISUT system itself. Homologous market families without a verified code in public sources for this exact configuration (½ circle, 20 mm conical point, USP 6/0, black, 75 cm) are: DAFILON® (B. Braun / Aesculap), Monosof™ (Medtronic / Covidien), DemeLON™ (DemeTECH) and SERALON® (Serag-Wiessner); they must be confirmed with each manufacturer before use as a substitute or in tendering. The cited brands belong to their respective manufacturers and are mentioned solely as an equivalence reference.
5. Selection tips and variants of interest
- Tissue to be sutured: USP gauge 6/0 (EP metric 0.7) is the microsurgery choice for very delicate planes (ophthalmology, neurosurgery) and thin skin. The conical-point needle separates fibres without cutting them, ideal for lax, vascular and well-irrigated tissues; for firm or poorly distensible tissues consider reverse cutting profiles from the same Premisut nylon range (e.g. AMP642XDS1360, XDS13 in 6/0).
- Needle length and radius: the 20 mm HR20 profile in ½ circle is the ideal option for surgical fields with very limited access (ophthalmology, minor surgery, paediatric surgery and neurosurgery). If the protocol prefers a ⅜ circle radius with a conical point, the DR13 variant in 6/0 is available (AMP642DR1360, 45 cm).
- Same HR20 Prime needle in other gauges: 5/0 (AMP642HR2050), 4/0 (AMP642HR2040), 3/0 (AMP642HR2030) and 2/0 (AMP642HR2020), all in black 75 cm thread, to unify the range and adjust the gauge to the tissue plane to be sutured.
- Prime vs. standard quality: the Prime range offers maximum sharpening precision and batch-to-batch consistency; if unit cost is a critical factor, the standard HR20 nylon range maintains the same dimensional specifications (AM642HR2060) with standard sharpening performance.
- Sterility verification: sterile product by ethylene oxide and single-use; check the blister integrity and expiry date before each use, and keep the reference P642HR2060 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.
For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.