Description
1. Commercial Introduction
The NYLON Suture PREMISUT Prime 1/2 Cylindrical HR40 mm 1 Black 2×75 cm (Ref. P642HR4001.2 · SKU AMP642HR4001.2) is the premium reference in the range of non-absorbable sutures from Cahnos for procedures requiring maximum sharpness precision and batch-to-batch consistency. It combines a nylon monofilament (polyamide 6 or 6.6) in identifying black, USP size 1 and two 75 cm strands with double needle, allowing suturing from both ends without re-mounting. It is a common choice in ophthalmology, neurosurgery, general surgery departments and purchasing centres that need a high-performance permanent suture, predictable clinical behaviour and complete batch traceability. Sterile, ready-to-use product, supplied in a box of 12 individual pouches.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely, gradually encapsulating and maintaining high tensile strength for more than three months, comfortably covering the critical healing phase. Being an uncoated monofilament, the suture slides easily through tissues, reduces the wicking effect and bacterial drag compared with multifilament sutures, and minimises the inflammatory reaction. The grooved finish of the strand improves knot retention and handling in the surgical field.
The HR40 Prime needle of 40 mm features a ½ circle curvature with a cylindrical body and conical point (taperpoint): the sharp point without cutting edges passes through tissues separating the fibres without cutting them, making it especially suitable for soft, well-vascularised tissues (fascia, peritoneum, muscle, conjunctiva) where minimising trauma is sought. Prime quality guarantees more consistent sharpness and more predictable penetration at every stitch. USP size 1 (metric EP 4) provides high tensile strength for tissues under medium-to-high tension, and the presentation of 2 sutures of 75 cm with double needle offers sufficient length for continuous sutures or multiple stitches without re-mounting. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Brand / Quality | PREMISUT Prime (premium range) |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament, grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / Size | USP 1 (metric EP 4) |
| Approximate thread diameter | 0.40 – 0.499 mm |
| Thread length | 2 strands of 75 cm (2 × 75 cm) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | ½ circle (1/2 circular), cylindrical body |
| Tip type | Conical / cylindrical (Taperpoint), grooved |
| Needle size | HR 40 Prime (40 mm) |
| Configuration | 2 needles, 2 sutures of 75 cm (double needle) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology, neurosurgery and general surgery |
| Commercial presentation | Box of 12 sterile individual sachets; batch traceability |
| Factory reference | P642HR4001.2 |
| Reference Cahnos (SKU) | AMP642HR4001.2 |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 1 | 4 | 0.40 – 0.499 mm |
3.3. PREMISUT HR40 family (½ circle needle, 40 mm, taperpoint, black suture)
| Needle profile | USP size | Thread | Reference |
|---|---|---|---|
| HR 40 Prime | 1 | 1 × 75 cm (black) | P642HR4001 / AMP642HR4001 |
| HR 40 Prime | 1 | 2 × 75 cm (black, double needle) | P642HR4001.2 / AMP642HR4001.2 (this product) |
| HR 40 Prime | 0 | 1 × 75 cm (black) | P642HR4010 / AMP642HR4010 |
| HR 40 Prime | 2 | 1 × 75 cm (black) | P642HR4002 / AMP642HR4002 |
| HR 40 Prime | 2 | 2 × 75 cm (black, double needle) | P642HR4002.2 / AMP642HR4002.2 |
The same family of ½ circle conical needles is available in shorter profiles such as HR30 (30 mm, series AMP642HR3001 and double version AMP642HR3001.2) and in the HR50 profile (50 mm, series AMP643HR5001) for larger surgical fields.
4. Equivalences and Cross-References
The reference P642HR4001.2 corresponds to the official nomenclature of the PREMISUT Prime range (HR40 profile: ½ circle needle with conical point of 40 mm, USP size 1, black grooved suture of 75 cm, double needle presentation 2×75 cm) and Cahnos markets it without altering characters: no digit should be added, removed or reordered when ordering or tendering.
Black non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercial type ‘Ethilon’). There is no manufacturer-validated equivalence table cross-referencing this product with other brands for the exact combination of USP 1 + ½ circle taperpoint needle of 40 mm + black 75 cm strand in double needle; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (J&J MedTech) | ETHILON® – black nylon monofilament, USP 1, 30″ thread (≈ 75 cm), CTX 48 mm needle (½ circle, taperpoint conical point) | 830H (verified in official Ethicon catalogue and authorised distribution) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6/6.6), USP size 1 (EP 4), black colour, ½ circle curvature, conical point family and suture length (75 cm); they differ in needle size (CTX 48 mm vs. HR40 40 mm, outside the ±1 mm tolerance) and configuration (single needle vs. double needle 2×75 cm). Confirm IFU and CE/MDR classification before substituting. |
| Medtronic / Covidien | Monosof™ – black nylon monofilament, USP 1, 40″ suture (≈ 100 cm), GS-25 needle of 48 mm (½ circle, taperpoint) | CN724 (verified on official Medtronic website, McKesson data sheet and authorised distribution) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6/6.6), USP size 1, black colour, ½ circle curvature and conical point family; they differ in needle size (GS-25 of 48 mm vs. 40 mm, outside the ±1 mm tolerance), suture length (100 cm vs. 2×75 cm) and configuration (single needle vs. double needle). Confirm IFU and CE/MDR classification before substituting. |
| DemeTECH | DemeLON™ – black nylon monofilament, USP 1, 30″ suture (75 cm), DCTX needle of 48 mm (½ circle, round body, conical point) | NL260148B0P (verified on official DemeTECH store, net32 and GUDID/FDA) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6/6.6), USP size 1, black colour, ½ circle curvature, conical point family and suture length (75 cm); they differ in needle size (DCTX of 48 mm vs. 40 mm, outside the ±1 mm tolerance) and configuration (single needle vs. double needle 2×75 cm). Confirm IFU and CE/MDR classification before substituting. |
| B. Braun (Aesculap) | DAFILON® – uncoated polyamide monofilament, USP 1 (EP 4), blue suture 100 cm, HR40 needle of 40 mm (½ circle, round body, conical point) | B0935549 (verified on official B. Braun catalogue and GUDID) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6/6.6), USP 1 gauge (EP 4), ½ circle curvature, conical point family and needle size (HR40 of 40 mm, identical within the tolerance of ±1 mm); they differ in thread colour (blue versus black), length (100 cm versus 2×75 cm) and configuration (single needle versus double). Confirm the IFU and CE/MDR classification before substituting. |
Other homologous families on the market that must be reviewed property by property (material, gauge, curvature, point family, needle and thread length, colour and CE/MDR regulatory classification) before any substitution: DERMALON™ (Medtronic), LUXAMID® (LuxSutures) and SUPRAMID® (SMI). No codes from these manufacturers have been verified in public sources for the exact HR40 40 mm, USP 1 and black 75 cm double-needle configuration; they must be confirmed with the manufacturer before use in substitution or tendering.
There is no equivalence table validated by the manufacturer for this configuration; check in the technical data sheet or instructions for use of the alternative manufacturer the exact gauge, thread length, needle geometry and size, colour and regulatory classification (CE/MDR) before using this information in tenders or direct substitution. This needle geometry (HR40 Prime, USP 1, double needle 2×75 cm) is only fully safely interchangeable within the PREMISUT system itself. Consult the technical department of Cahnos to validate any equivalence.
5. Selection tips and variants of interest
- Tissue to suture: the USP 1 (EP 4) gauge offers high tensile strength for subcutaneous tissue, fasciae, aponeuroses and soft tissues under high tension, always with a conical point needle to minimise tissue damage. For finer planes, consider USP 0 (Ref. AMP642HR4010) or lower gauges from the same Prime family.
- Needle length: the HR40 40 mm profile covers medium-depth accesses. For smaller fields, the HR30 family from the same Prime range is available (Ref. AMP642HR3001 and double version AMP642HR3001.2); for larger fields, the HR50 profile (Ref. AMP643HR5001).
- Thread length and presentation: this reference is double-needle 2×75 cm, ideal for continuous sutures without re-swaging or for dividing the thread across two fields. If you prefer a single 75 cm strand, the Ref. AMP642HR4001 is available; if you need a larger gauge, the USP 2 version (Ref. AMP642HR4002) and its double version (Ref. AMP642HR4002.2).
- Prime quality: if the procedure requires maximum sharpening precision and batch-to-batch consistency, the Prime range offers this same geometry and gauge; if unit cost is a critical factor, the standard range (Ref. AM642HR4001) maintains the same dimensional specifications with standard sharpening performance.
- Sterility verification: sterile product by ethylene oxide and single-use; check the blister integrity and expiry date before each use, and keep the reference P642HR4001.2 and batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.
For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial manufacturers, contact the technical-commercial team of Cahnos.





Reviews