Description
1. Commercial Introduction
The NYLON Suture PREMISUT 1/2 Cylindrical HR37 (factory ref. 642HR3720 · SKU AM642HR3720) is a permanent reference in the standard range of non-absorbable nylon sutures for procedures requiring a thread with predictable clinical behaviour, mounted on a cylindrical-bodied needle with a conical point. It combines a monofilament of polyamide 6 or 6.6 in identifying black, USP 2/0 (metric EP 3) gauge and a 75 cm fluted strand without coating, on a ½ circle needle with a 37 mm taperpoint tip (HR37 profile).
It is a common choice in ophthalmology, neurosurgery and general surgery departments, as well as in purchasing centres and tenders seeking a permanent thread with full batch traceability and an excellent balance between price and performance. Sterile, ready-to-use product, supplied in a box of 12 individual sterile sachets.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely, gradually encapsulating and maintaining high tensile strength for more than three months, comfortably covering the critical healing phase. Being an uncoated monofilament, the thread slides easily through tissues, reduces the wick effect and bacterial drag compared with multifilaments, and minimises the inflammatory reaction. The fluted finish of the strand improves knot retention and handling in the surgical field, while the black colour ensures optimal contrast on the field.
The 37 mm HR37 needle features a ½ circle curvature with a cylindrical body and conical (taperpoint) point: the sharp point without cutting edges passes through tissues by separating the fibres without cutting them, making it especially suitable for soft, well-vascularised tissues (fascia, peritoneum, muscle, conjunctiva) where minimising trauma is sought. The USP 2/0 (metric EP 3) gauge provides medium strength with excellent handling, ideal for superficial planes and low-to-medium tension tissues, and the 75 cm of thread offers sufficient length for continuous sutures or multiple stitches without re-threading. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical specifications and tables
3.1. General characteristics
| Parameter | Specification |
| Brand / Quality | PREMISUT (standard range) |
| Factory reference | 642HR3720 |
| Reference Cahnos (SKU) | AM642HR3720 |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament with grooved surface |
| Coating | None |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / Size | USP 2/0 (metric EP 3), conforming to USP and European Pharmacopoeia gauges |
| Approximate thread diameter | 0.30 – 0.339 mm |
| Thread length | 75 cm (free end, without loop) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | 1/2 circle (½ circular), cylindrical body |
| Tip type | Conical / Taperpoint, grooved |
| Needle size | HR 37 (37 mm) |
| Configuration | 1 needle per unit, 1 thread of 75 cm |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units in individual sterile sachets; batch traceability |
| Regulatory standard | Complies with USP/EP Pharmacopoeia; CE marking (MDR) |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 3/0 | 2 | 0.20 – 0.249 mm |
| 2/0 (this product) | 3 | 0.30 – 0.339 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
| 2 | 5 | 0.50 – 0.599 mm |
The thread diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without extending their limits.
3.3. PREMISUT HR37 family (½ circle 37 mm needle, taperpoint conical tip, black thread)
| Needle profile | USP size | Thread | Reference |
| HR 37 (standard) | 1 | 1 × 75 cm (black) | 642HR3701 / AM642HR3701 |
| HR 37 (standard) | 0 | 1 × 75 cm (black) | 642HR3710 / AM642HR3710 |
| HR 37 (standard) | 2/0 | 1 × 75 cm (black) | 642HR3720 / AM642HR3720 (this product) |
| HR 37 Prime | 2/0 | 1 × 75 cm (black) | P642HR3720 / AMP642HR3720 |
| HR 37 Prime | 2/0 | 2 × 75 cm (black, double thread) | P642HR3720.2 / AMP642HR3720.2 |
The same conical HR37 needle is available in other gauges (USP 1, 0) and in shorter needle profiles (HR26, HR30) or longer ones (HR40, HR50, series 643) for procedures requiring shorter or longer travel.
4. Equivalences and Cross-References
Reference 642HR3720 corresponds to the official nomenclature of the PREMISUT range (HR37 profile: ½ circle needle with 37 mm taperpoint conical point, USP 2/0 gauge, 75 cm black fluted thread) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering.
Non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercial type ‘Ethilon’). There is no manufacturer-validated equivalence table cross-referencing this specific configuration (½ circle needle with 37 mm conical point, USP 2/0 gauge, 75 cm black strand) with references from other houses; the analogous brands and families that must be reviewed property by property (material, gauge, curvature, point family, needle and strand length, colour and CE/MDR regulatory classification) before any substitution are: ETHILON® (Ethicon / J&J MedTech, black nylon monofilament), Monosof™ and Dermalon™ (Medtronic / Covidien), DemeLON™ (DemeTECH), SERALON® (Serag-Wiessner), LUXAMID® (LuxSutures) and SUPRAMID® (SMI). No reference from these houses has been verified in public sources that combines the exact HR37 37 mm + USP 2/0 + conical point + 75 cm black strand configuration.
Verification warning: reference C0930701 from the DAFILON® family (B. Braun) is cited in some secondary sources as an HR37 37 mm needle in USP 2/0 gauge; however, the GUDID/FDA regulatory database records it as DAFILON BLUE in USP 3/0 (EP 2) gauge, so it must not be used as an equivalent of a 2/0. Always confirm the exact gauge in the technical data sheet or IFU of the alternative manufacturer.
There is no manufacturer-validated equivalence table; consult the technical department before use in tenders. This needle geometry (HR37, USP 2/0, 75 cm black strand) is only fully safely interchangeable within the PREMISUT system itself: the Prime version with identical geometry and gauge (Ref. P642HR3720 · SKU AMP642HR3720) is a direct equivalent within the same manufacturer, and the double-thread Prime 2 × 75 cm presentation is supplied under Ref. P642HR3720.2 (SKU AMP642HR3720.2). Consult the technical department at Cahnos to validate any equivalence.
5. Selection tips and variants of interest
- Tissue to suture: the USP 2/0 (metric EP 3) gauge offers an excellent balance between strength and handling for subcutaneous tissue, skin with low-to-medium tension, mucous membranes and superficial planes, always with a conical-point needle to minimise tissue damage. For finer planes, consider USP 3/0 from the same family; for higher loads, USP 0 (Ref. AM642HR3710) or USP 1 (Ref. AM642HR3701) with the same HR37 needle.
- Prime quality: if the procedure requires maximum sharpening precision and batch-to-batch consistency, the Prime range offers this same geometry and gauge (Ref. P642HR3720 · SKU AMP642HR3720), a direct equivalent within the same manufacturer. If unit cost is a critical factor, this standard reference maintains the same dimensional specifications with standard sharpening performance.
- Double presentation: if the protocol requires two strands for continuous sutures without re-threading or to split the material across two surgical fields, it is available with the same needle and gauge in a double thread Prime 2 × 75 cm (Ref. P642HR3720.2 · SKU AMP642HR3720.2).
- Needle length: the HR37 profile of 37 mm covers medium-depth access. For smaller fields, the HR30 family is available (Ref. 642HR3020 / AM642HR3020 in USP 2/0) or HR26 (Ref. 642HR2620 / AM642HR2620 in USP 2/0); for deeper access, the HR40 or HR50 profiles (series 643).
- Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use, and keep the reference 642HR3720 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.
- B2B conditions: for volume purchases, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.