We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Suture NYLON PREMISUT Prime · Needle 1/2 Circle Triangular Reverse Cutting HS26 (26 mm) · USP 2/0 (EP 3) · Black Thread 75 cm · Non-Absorbable Polyamide Monofilament · Box of 12 units (Ref. P642HS2620)

13,83 €

Suture NYLON PREMISUT Prime non-absorbable: uncoated polyamide monofilament (nylon 6/6.6), gauge USP 2/0 (metric EP 3), high-visibility black colour and 75 cm fluted strand with wound support greater than 3 months. It features a ½-circle needle with a triangular reverse cutting point HS26 Prime, 26 mm, the ideal geometry for skin, mucous membranes and firm tissues, as well as for precise approximation in ophthalmology and neurosurgery. Sterile by ethylene oxide, single-use, in a box of 12 individual pouches with batch traceability. Ref. P642HS2620 · SKU AMP642HS2620.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP642HS2620

Description

1. Commercial Introduction

The NYLON Suture PREMISUT Prime in USP size 2/0 with a ½ circle needle, reverse cutting triangular point of 26 mm (HS26 Prime profile) and black 75 cm strand is one of the most requested configurations in the non-absorbable suture catalogue from Cahnos for B2B supply: operating theatres, purchasing groups, general and specialised surgery departments, ophthalmology clinics and neurosurgery units. It combines a nylon monofilament (polyamide 6 or 6.6) with predictable clinical behaviour, identifying black colour and uncoated ribbed finish, mounted on a Prime needle with maximum sharpening precision. Sterile product, ready to use and with full batch traceability, designed for hospital replenishment, tenders and volume contracts.

2. Technical Explanation

Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely: it is gradually encapsulated by fibrous connective tissue and retains high tensile strength for more than three months, comfortably covering the critical healing phase. As an uncoated monofilament, the thread slides easily through tissues, reduces the sawing effect, minimises bacterial adhesion compared to multifilaments and promotes a firm, stable knot; its ribbed finish improves knot grip and prevents slippage.

The HS26 Prime 26 mm needle has a ½ circle curvature with a reverse cutting triangular body and point: the cutting edge cuts outward from the wound, preserving the skin edge and preventing the incision from enlarging. The ribbed needle body improves needle holder grip and rotation transmission, with a clean entry hole and a quality cosmetic result. This geometry is aimed at skin, mucosa and firm tissues of medium consistency, as well as precision approximation in ophthalmology and neurosurgery.

3. Technical Specifications

Parameter Specification
Factory reference P642HS2620
Reference Cahnos (SKU) AMP642HS2620
Brand / Quality Premisut Prime (premium range)
Thread material Nylon monofilament (polyamide 6 / 6.6), uncoated
Thread structure Monofilament, grooved finish
Absorption Non-absorbable; gradual encapsulation, wound support for more than 3 months
Gauge / USP size USP 2/0 (metric 3 / EP 3), conforming to USP and European Pharmacopoeia gauges
Strand diameter 0.30 – 0.339 mm
Thread length 75 cm (1 needle per suture)
Thread colour Black identifier (high visibility in surgical field)
Needle shape ½ circle (1/2 circular), grooved body
Tip type Reverse cutting triangular (Reverse Cutting), triangular body and point
Needle size HS26 Prime (26 mm)
Configuration 1 needle per suture
Sterilisation Ethylene oxide (EO); sterile, single-use, non-resterilisable
Indications Approximation of soft tissues, ligatures, ophthalmology and neurosurgery
Commercial presentation Box of 12 units (sterile individual sachets); batch traceability
Regulatory standard Complies with USP/EP Pharmacopoeia for non-absorbable sutures; CE marking (MDR)

Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture):

USP size Metric measurement (EP) Approximate thread diameter
4/0 1.5 0.15 – 0.199 mm
3/0 2 0.20 – 0.249 mm
2/0 (this product) 3 0.30 – 0.339 mm
0 3.5 0.35 – 0.399 mm

The thread diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without exceeding its limits. Minimal tissue reaction, excellent tensile strength, secure knot and completely predictable behaviour as there is no polymer degradation in the body.

4. Equivalences and Cross-References

The reference P642HS2620 corresponds to the official nomenclature of the PREMISUT Prime range (HS26 Prime reverse cutting needle 26 mm, USP size 2/0, black ribbed thread 75 cm) and Cahnos markets it without altering characters: no digit should be added, removed or reordered when ordering or tendering.

There is no manufacturer-validated equivalence table that cross-references this specific configuration (½ circle HS26 needle 26 mm, USP 2/0, black, 75 cm) with references from other brands; the following match is a functional comparison verified against the manufacturer’s official store and authorised distribution, and should not be treated as interchangeable 1:1 without prior technical validation.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
DemeTECH DemeLON® – black nylon monofilament, USP 2/0, 75 cm, 26 mm DCP-2 ½ circle reverse cutting needle NL262026B4P (confirmed in DemeTECH official store) Comparable by category (not interchangeable 1:1) They match in material (nylon 6/6.6), USP size 2/0, black colour, thread length (75 cm), ½ circle curvature, needle size (26 mm) and reverse cutting point; they differ in needle profile (DCP-2 vs. HS26), manufacturer and commercial presentation. Confirm IFU and CE/MDR marking before substituting.

Other homologous families of non-absorbable nylon monofilament must be reviewed property by property (material, size, curvature, point family, needle and strand length, colour and CE/MDR regulatory classification) before any substitution: Ethicon ETHILON® (its verified reference W1626BH mounts a PS Prime needle of 26 mm but in ⅜ circle curvature, not ½; no ETHILON code with a ½ circle 26 mm needle in this configuration has been located in public sources), Medtronic MONOSOF™ (reference SN-682 mounts a C-25 needle of 30 mm in ½ circle with reverse cutting, outside the ±1 mm tolerance with respect to the HS26 of 26 mm, and SN-664 is ⅜ curvature) and B. Braun DAFILON® (polyamide; the black polyamide 6.6 variant is reserved for microsurgery and ophthalmology, and the blue reference C0935360 in USP 2/0 mounts a DS24 needle of 24 mm in ⅜ circle: they differ in colour, curvature and needle size). None of these references enters the table because they do not meet all matching fields.

There is no manufacturer-validated equivalence table for this configuration (HS26 needle 26 mm, USP 2/0, black, 75 cm); consult with the technical-commercial department of Cahnos before using in a tender. This needle geometry (HS26 Prime, USP 2/0, 75 cm) is only interchangeable with full safety within the PREMISUT system itself. The brands cited belong to their respective manufacturers and are mentioned only as an equivalence reference.

5. Selection tips and variants of interest

Size according to anatomical area: USP 2/0 (metric EP 3) is very versatile, indicated for skin, subcutaneous tissue and soft tissues with moderate tension, as well as for precision approximation in ophthalmology and neurosurgery; for finer planes consider the 3/0 of the same HS26 Prime family (AMP642HS2630).

Presentation: if the protocol requires several stitches without re-threading, the same configuration is available in double thread format 2 × 75 cm (AMP642HS2620.2), and for a more adjusted cost there is the standard non-Prime range (AM642HS2620).

Needle length and profile: for deeper planes or wide fields you have the same range in DS26 profiles (3/8 circle, AMP642DS2620) and HR26 (taper point, AMP642HR2620).

Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use, and keep the reference P642HS2620 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.

For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team of Cahnos.

Additional information

Manufacturer reference

P642HS2620

Product line

Premisut Prime (premium range)

Material

Nylon monofilament (polyamide 6 / 6.6), uncoated

Structure

Monofilament, grooved finish

Absorption

Non-absorbable; gradual encapsulation, wound support for more than 3 months

USP size

2/0 (metric 3 / EP 3)

Thread diameter

0.30 – 0.339 mm

Needle shape

½ circle (1/2 circular), grooved body

Tip type

Reverse cutting triangular (Reverse Cutting), triangular body and point

Needle size

HS26 Prime (26 mm)

Configuration

1 needle per suture

Sterilisation

Ethylene oxide (EO); sterile, single-use, non-resterilisable

Use

Single-use, sterile. Do not re-sterilise

Presentation

Box of 12 units (individual sterile sachets)

Indications

Approximation of soft tissues, ligatures, ophthalmology and neurosurgery

Regulatory standard

Conforms to USP/EP Pharmacopoeia; CE marking (MDR)

Thread structure

Monofilament, grooved finish

Needle tip

Triangular reverse cutting (Reverse Cutting)

Swaged

1 needle per suture

Medida de aguja

HS 26

Usp

2/0

Color

Black

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Suture NYLON PREMISUT Prime · Needle 1/2 Circle Triangular Reverse Cutting HS26 (26 mm) · USP 2/0 (EP 3) · Black Thread 75 cm · Non-Absorbable Polyamide Monofilament · Box of 12 units (Ref. P642HS2620)”

Your email address will not be published. Required fields are marked *