Description
1. 3-piece insulin syringe: precision for the diabetic patient’s day-to-day
The insulin syringe Nipro MYSHOT™ 3-part with fixed needle is the classic, reliable solution for daily subcutaneous insulin administration. With a capacity of 1 ml and U-100 graduation (100 units), it allows the exact dose prescribed by the healthcare professional to be loaded and administered, with a smooth puncture thanks to its ultra-thin triple-bevel needle and a uniform, effortless plunger movement. It is presented in an individual blister and a box of 100 units, ideal for hospitals, clinics, pharmacies and patients who need a continuous supply with guaranteed sterility until the moment of use.
2. Technical Explanation
This syringe from the MYSHOT™ line of Nipro is constructed in three parts: barrel, plunger and seal. The double-contact seal, made of polyisoprene rubber, guarantees an airtight seal that allows easy, controlled, leak-free injection; the transparent polypropylene barrel allows the unit scale to be read clearly, printed in dark stroke and conforming to standard ISO 7886-1. The fixed needle of SUS-304 stainless steel, 30G × 13 mm (0.3 × 13 mm), ultra-thin and triple-bevel, minimises discomfort during puncture. The design integrates finger grips and a large push disc for safe handling, and its low residual volume (< 0.07 ml) reduces insulin loss and the risk of incorrect dosing at the end of the stroke. It is a single-use product, sterilised by ethylene oxide, latex-free and pyrogen-free, suitable for administration of U-100 insulin by subcutaneous injection.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Product type | 3-piece insulin syringe with fixed needle, sterile, single-use |
| Line / family | Nipro MYSHOT™ (blister-packed) |
| Official manufacturer reference | SYMS1U1003013B-EC |
| SKU Cahnos | SYMS1U1003013BEC |
| Capacity | 1 ml (100 IU, U-100 concentration) |
| Graduation / scale | U-100 scale; 1 division = 0.01 ml (1 IU) |
| Needle | Fixed, ultra-fine triple-bevel, 30G × 13 mm (0.3 mm × 13 mm) |
| Barrel | Transparent polypropylene (PP) |
| Plunger | Polypropylene (PP) |
| Gasket | Elastomer / double-contact polyisoprene rubber |
| Cannula | Stainless steel SUS-304 |
| Lubricant | Silicone (dimethicone oil, traces) |
| Residual volume | < 0.07 ml (low) |
| Materials | Latex-free, BPA-free, DEHP-free, PVC-free |
| Sterilisation | Ethylene oxide (EO); shelf life 5 years |
| Regulatory classification | Medical device class IIa, rule 6 (MDD 93/42/EEC) |
| Standards | ISO 8537:2016 · ISO 7864:2016 · ISO 11135 · EN ISO 10993-4 and 10993-11 |
| Barrel printing | In accordance with ISO 7886-1, carbon black ink, Nipro logo |
| Symbols and labelling | EN 980:2003 · ISO/CD 15223-1:2007 |
| Colour identification | ISO 6009:1992 (single-use hypodermic needles) |
| Individual packaging | Paper and polyethylene/polypropylene film blister (152 × 34 mm); in accordance with BS EN 868:1999 |
| Presentation | Individual blister; inner box of corrugated cardboard with 100 units; outer box with 36 inner boxes (3,600 units) |
Materials (according to official MYSHOT™ technical data sheet): piston in isoprene rubber; plunger, barrel and cap in polypropylene; lubricant dimethicone oil; printing ink carbon black; stainless steel needle. All materials are suitable for medical use, contain no latex or pyrogens.
4. Equivalences and Cross-References
Verification status (codes): the official manufacturer reference SYMS1U1003013B-EC is CONFIRMED against the official technical data sheet of Nipro (MYSHOT™ datasheet) and the brand’s distribution catalogues; the Cahnos SKU (SYMS1U1003013BEC) is a proprietary code that reproduces the official construction without hyphens. Within the same Nipro family there are variants of the same volume with other gauges and lengths —SYMS1U1002913B-EC (29G × 13 mm), SYMS1U1003008B-EC (30G × 8 mm) or SYMS05U1003013B-EC (0.5 ml)— that share design and materials but are not 1:1 interchangeable when the gauge, needle length or volume changes.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Embecta (formerly BD) | Ultra-Fine™ (U-100 insulin syringe) | 328411 | Comparable by category (not interchangeable 1:1) | 1 ml U-100; fixed needle 30G × 12.7 mm; same capacity and same gauge, needle 0.3 mm shorter; blister packed. Code verified in GUDID (catalog 328411, Embecta Medical II LLC). |
| Terumo | Myjector / insulin syringe with needle | SS.10M2913KA | Comparable by category (not interchangeable 1:1) | 1 ml U-100; fixed needle 29G × 13 mm; same needle length, gauge 0.04 mm larger (29G vs 30G). Code verified at Thermo Fisher and authorised distributors. |
Other short-needle market references have also been verified (embecta Ultra-Fine™ 320469 and B. Braun Omnican® 100 9151133S, both 1 ml and 30G × 8 mm) which cannot be considered interchangeable with this product due to the difference in needle length (8 mm vs 13 mm), outside the acceptable tolerance for substitution.
There is no equivalence table validated by the manufacturer that cross-references this product with other manufacturers; consult the technical department before using in tenders or substitution. For any substitution between brands, each field must be checked: insulin concentration (U-100), nominal capacity, graduation, needle gauge and length, residual volume, materials (latex-free, BPA, DEHP and PVC-free), sterility and regulatory classification of the actual product.
5. Selection tips and variants of interest
- For small doses or paediatric patients, consider the 0.5 ml variant of the same Nipro family (Ref. SYMS05U1002913B-EC, 29G × 13 mm).
- If a shorter needle is preferred for scant subcutaneous tissue, the 30G × 8 mm variant (Ref. SYMS1U1003008B-EC) reduces the puncture length, although it is not 1:1 interchangeable with this reference.
- Always check the vial concentration: a U-100 syringe with U-40 insulin would dose 2.5 times more; the U-100 and U-40 scales are not interchangeable.
- Single-use product: dispose of each syringe after administration in a biohazard container, in accordance with the facility’s regulations.
- Storage: store in a dry, cool place protected from light; open the blister only at the time of use to guarantee sterility.




Reviews