Description
1. Introduction
The Nipro SafeTouch 18G x 50 mm safety intravenous catheter with wings and injection port (ref. NIC-SF-1850PWP-ET) is the solution your nursing service needs for fast, reliable and fully protected peripheral vascular access. It combines the comfort of secure wings, the versatility of a Y injection port and a passive safety mechanism that protects the professional against accidental needlestick injuries, one of the most common occupational hazards in healthcare settings. Supplied in a box of 50 sterile units, it is the usual choice in hospitalisation, emergency departments, outpatient clinics and transfusion services when a large gauge and high flow rate are required.
2. Technical Explanation
This peripheral safety catheter incorporates a passive and irreversible activation system: upon withdrawing the needle after venipuncture, the stainless steel protector automatically advances and covers the tip, with the lock confirmed by an audible click, requiring no additional action from the professional and without changing the puncture technique. The flexible wings provide a firm grip and precise control during insertion, and also facilitate securing the catheter to the patient’s limb once cannulated. The Y injection port with a universal luer connector allows administration of medication boluses or system flushing without disconnecting the main line, reducing unnecessary manipulations and the risk of contamination. The thermosensitive and radiopaque polyurethane cannula softens at body temperature, adapting to the venous bed, minimising kinking and maintaining a guaranteed minimum flow rate of 81 ml/min. The stainless steel needle with triple-bevel and silicone coating reduces penetration force and patient discomfort. It is manufactured latex-free, DEHP-free and PVC-free.
3. Technical Specifications
| Manufacturer reference | NIC-SF-1850PWP-ET |
| Brand / line | Nipro SafeTouch, catheter with wings and injection port |
| Gauge | 18G (green) |
| Size (diameter x length) | 1.3 x 50 mm (2″) |
| Minimum flow rate | ≥ 81 ml/min |
| Cannula material | Thermosensitive, radiopaque polyurethane (PUR) |
| Needle material | Stainless steel SUS-304, triple bevel, silicone-coated |
| Safety system | Passive and irreversible, with audible click lock (SafeTouch) |
| Design | Colour-coded flexible wings + Y injection port with universal Luer connector |
| Sterility | Sterile, single-use |
| Composition | Latex-free, DEHP and PVC-free |
| Presentation | Box of 50 units |
| Indications | Intravenous infusion, injection and transfusion |
| Regulatory classification | CE Class IIa medical device (Rule 7, MDD 93/42/EEC); compliant with ISO 10555-5, ISO 7864 and ISO 23908 |
Full range available in the same manufacturer line (catheter with wings and injection port), with references verified in the official technical data sheet:
| Reference | Gauge / Size | Minimum flow rate |
| NIC-SF-1650PWP-ET | 16G x 2″ (1.7 x 50 mm) | ≥ 162 ml/min |
| NIC-SF-1832PWP-ET | 18G x 1 1/4″ (1.3 x 32 mm) | ≥ 81 ml/min |
| NIC-SF-1850PWP-ET | 18G x 2″ (1.3 x 50 mm) | ≥ 81 ml/min |
| NIC-SF-2032PWP-ET | 20G x 1 1/4″ (1.1 x 32 mm) | ≥ 49 ml/min |
| NIC-SF-2050PWP-ET | 20G x 2″ (1.1 x 50 mm) | ≥ 49 ml/min |
| NIC-SF-2225PWP-ET | 22G x 1″ (0.8 x 25 mm) | ≥ 29 ml/min |
| NIC-SF-2232PWP-ET | 22G x 1 1/4″ (0.8 x 32 mm) | ≥ 29 ml/min |
| NIC-SF-2419PWP-ET | 24G x 3/4″ (0.7 x 19 mm) | ≥ 17 ml/min |
| NIC-SF-2425PWP-ET | 24G x 1″ (0.7 x 25 mm) | ≥ 17 ml/min |
4. Equivalences and Cross-References
Within the same manufacturer family (SafeTouch with wings and Y injection port), this catheter shares design, material and safety system with other sizes. The references from the same line verified in the manufacturer’s official documentation are shown below:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Nipro | SafeTouch with wings and injection port | NIC-SF-1832PWP-ET | Comparable by category (not interchangeable 1:1) | 18G x 32 mm (1.3 x 32 mm): same gauge, flow rate 81 ml/min and design; shorter usable length. Reference verified in official data sheet |
| Nipro | SafeTouch with wings and injection port | NIC-SF-2050PWP-ET | Comparable by category (not interchangeable 1:1) | 20G x 50 mm (1.1 x 50 mm): same length and design; smaller gauge and flow rate 49 ml/min. Reference verified in official data sheet |
| Nipro | SafeTouch with wings and injection port | NIC-SF-1650PWP-ET | Comparable by category (not interchangeable 1:1) | 16G x 50 mm (1.7 x 50 mm): same length; larger gauge for high flow rates (162 ml/min). Reference verified in official data sheet |
| Nipro | SafeTouch with wings (without injection port) | NIC-SF-1850P-ET | Comparable by category (not interchangeable 1:1) | 18G x 50 mm: same gauge and length, but without Y injection port; not interchangeable if the protocol requires a Y port |
As for other manufacturers, the product is comparable at category level with peripheral safety catheters with injection port and wings from brands such as B. Braun (Introcan Safety line), BD (Nexiva and Insyte Autoguard lines) or Vygon (Leader-Cath). Before substituting in a tender or internal protocol, the professional must verify in each brand’s technical data sheet the following fields: equivalent gauge, cannula length, material (polyurethane versus other polymers), type of safety mechanism (active/passive), presence of injection port and presentation per box. There is no equivalence table validated by the manufacturer that cross-references these references with other brands; consult with the technical department before using in a tender.
5. Selection tips and variants of interest
The 18G gauge with 50 mm length is an ideal choice for medium-duration access in adult patients with medium-calibre veins or for situations requiring a high flow rate (≥ 81 ml/min): surgery, emergency departments, administration of blood and blood products, or high-viscosity fluids. For paediatric patients or those with fragile veins, it is recommended to reduce the gauge (22G x 25 mm, ref. NIC-SF-2225PWP-ET, or 24G from the same line). For very high-flow transfusions, choose the 16G x 50 mm (ref. NIC-SF-1650PWP-ET, flow rate 162 ml/min). If your protocol requires an injection port, always check that the code includes the suffix PWP (Y port), as the SafeTouch line offers variants without a port (suffix P) that are not interchangeable 1:1. Always purchase presentations of 50 units to ensure correct stock rotation and availability in hospitalisation, emergency and operating theatre services.