Description
1. Introduction
The intravenous safety catheter with wings and injection port Nipro SafeTouch 20G x 32 mm (ref. NIC-SF-2032PWP-ET) is the solution your nursing service needs to achieve fast, reliable and fully protected peripheral vascular access. It combines the comfort of securement wings, the versatility of a Y injection port and a passive safety mechanism that protects the professional against accidental needlestick injuries, one of the most common occupational hazards in the healthcare environment. Supplied in a box of 50 sterile units, it is the usual choice in hospitalisation, emergency, outpatient and transfusion services.
2. Technical Explanation
This peripheral safety catheter incorporates a system of passive and irreversible activation: upon removal of the needle after venipuncture, the stainless steel protector advances automatically and covers the tip, with the lock confirmed by an audible click, without requiring any additional manoeuvre from the professional and without changing the puncture technique. The flexible wings allow a firm grip and precise control during insertion, and also facilitate fixation of the catheter to the patient’s limb once cannulated. The Y injection port with universal Luer connector allows administration of medication boluses or flushing of the system without disconnecting the main line, reducing unnecessary manipulations and the risk of contamination. The thermosensitive and radiopaque polyurethane cannula softens at body temperature, adapting to the venous bed, minimises kinking and maintains a guaranteed minimum flow rate of 49 ml/min. The stainless steel needle with triple bevel and silicone coating reduces penetration force and patient discomfort. It is manufactured latex-free, DEHP-free and PVC-free: infusion duration from hours to several days, depending on clinical indication.
3. Technical Specifications
| Manufacturer reference | NIC-SF-2032PWP-ET |
|---|---|
| Brand / line | Nipro SafeTouch, catheter with wings and injection port |
| Gauge | 20G (pink) |
| Size (diameter x length) | 1.1 x 32 mm (1 1/4″) |
| Minimum flow rate | ≥ 49 ml/min |
| Cannula material | Thermosensitive, radiopaque polyurethane (PUR) |
| Needle material | Stainless steel SUS-304, triple bevel, silicone-coated |
| Safety system | Passive and irreversible, with audible locking click |
| Design | Colour-coded flexible wings + Y injection port with universal Luer connector |
| Sterility | Sterile, single-use |
| Composition | Latex-free, DEHP and PVC-free |
| Presentation | Box of 50 units |
| Indications | Intravenous infusion, injection and transfusion |
| Regulatory classification | CE Class IIa medical device (Rule 7, MDD 93/42/EEC); compliant with ISO 10555-5, ISO 7864 and ISO 23908 |
Full range available in the same manufacturer’s line (catheter with wings and injection port), with references verified in the official technical data sheet:
| Reference | Gauge / Size | Minimum flow rate |
|---|---|---|
| NIC-SF-1650PWP-ET | 16G x 2″ (1.7 x 50 mm) | ≥ 162 ml/min |
| NIC-SF-1832PWP-ET | 18G x 1 1/4″ (1.3 x 32 mm) | ≥ 81 ml/min |
| NIC-SF-1850PWP-ET | 18G x 2″ (1.3 x 50 mm) | ≥ 81 ml/min |
| NIC-SF-2032PWP-ET | 20G x 1 1/4″ (1.1 x 32 mm) | ≥ 49 ml/min |
| NIC-SF-2050PWP-ET | 20G x 2″ (1.1 x 50 mm) | ≥ 49 ml/min |
| NIC-SF-2225PWP-ET | 22G x 1″ (0.8 x 25 mm) | ≥ 29 ml/min |
| NIC-SF-2232PWP-ET | 22G x 1 1/4″ (0.8 x 32 mm) | ≥ 29 ml/min |
| NIC-SF-2419PWP-ET | 24G x 3/4″ (0.7 x 19 mm) | ≥ 17 ml/min |
| NIC-SF-2425PWP-ET | 24G x 1″ (0.7 x 25 mm) | ≥ 17 ml/min |
4. Equivalences and Cross-References
Within the same manufacturer’s family (SafeTouch with wings and Y injection port), this catheter shares design, material and safety system with other sizes. The references from the same line verified in the manufacturer’s official documentation are shown below:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Nipro | SafeTouch with wings and injection port | NIC-SF-2050PWP-ET | Comparable by category (not interchangeable 1:1) | 20G x 50 mm (1.1 x 50 mm): same gauge, design and flow rate; longer usable length. Reference verified in official data sheet |
| Nipro | SafeTouch with wings and injection port | NIC-SF-1832PWP-ET | Comparable by category (not interchangeable 1:1) | 18G x 32 mm (1.3 x 32 mm): larger gauge, flow rate 81 ml/min, same length |
| Nipro | SafeTouch with wings and injection port | NIC-SF-2232PWP-ET | Comparable by category (not interchangeable 1:1) | 22G x 32 mm (0.8 x 32 mm): smaller gauge, flow rate 29 ml/min, same length |
As for other manufacturers, the product is comparable at category level with peripheral safety catheters with injection port and wings from brands such as B. Braun (Introcan Safety line), BD (Nexiva and Insyte Autoguard lines) or Vygon (Leader-Cath). Before substituting in a tender or internal protocol, the professional must verify in each brand’s technical data sheet the following fields: equivalent gauge, cannula length, material (polyurethane versus other polymers), type of safety mechanism (active/passive), presence of injection port and presentation per box. There is no equivalence table validated by the manufacturer that cross-references these references with other brands; consult the technical department before use in a tender.
5. Selection tips and variants of interest
The 20G gauge with 32 mm length is a balanced choice for medium-duration access in adult patients with medium-sized veins, suitable for most infusion fluids, medication administration and blood transfusions. For paediatric patients or those with fragile veins, it is recommended to reduce the gauge (22G x 25 mm, ref. NIC-SF-2225PWP-ET, or 24G from the same line). For surgery, emergency or high-flow transfusions, opt for larger gauges such as 18G or 16G from the same family, with flow rates of 81 and 162 ml/min respectively. If your protocol requires an injection port, always check that the code includes the PWP suffix (Y port), as the SafeTouch line offers variants without a port that are not interchangeable 1:1. Always purchase 50-unit presentations to ensure correct stock rotation and availability in hospitalisation, emergency and operating theatre services.