Description
1. Commercial Introduction
The SafeTouch IV safety catheter from Nipro in 18G gauge and 32 mm length (1 1/4″), reference NIC-SF-1832P-ET, is the solution your nursing service needs to establish rapid, reliable and fully protected peripheral venous access in adult patients requiring high flow rates. Its passive safety technology, its biocompatible polyurethane cannula and its straight, wingless design respect the classic puncture technique and make it a common choice in hospitalisation, emergency, ICU, operating theatre and transfusion services. It is supplied in a box of 50 sterile single-use units.
2. Technical explanation of the device
In peripheral intravenous cannulation, the catheter is introduced mounted on a metal needle that passes through skin and venous wall; once blood return (flashback) is confirmed in the transparent body of the connector, the stylet is removed and the flexible cannula remains inside the vein to administer fluids, medication or blood products. The SafeTouch from Nipro technology is a passive and irreversible protection mechanism: when the needle is withdrawn, the protector advances automatically and covers the tip without requiring any additional manoeuvre from the professional or changing the puncture technique, in line with European Directive 2010/32/EU on the prevention of risks from sharp objects.
The cannula is made of thermosensitive, biocompatible and radiopaque polyurethane (PUR), a flexible and resistant material that softens with body temperature, reducing irritation of the venous wall and the risk of kinking in prolonged accesses. The luer-type connection allows coupling infusion equipment, three-way stopcocks or standard extension lines. All components are free of latex and PVC, and the product meets the applicable requirements of standards ISO 10555-5, ISO 7864 and ISO 23908 as a CE class IIa medical device.
3. Technical Specifications
| Specification | Value |
|---|---|
| Brand / Line | Nipro, SafeTouch IV family (straight, without wings) |
| Reference (SKU Cahnos) | NIC-SF-1832P-ET |
| Manufacturer catalogue code | NI-CSF1832PET (coding pattern of the SafeTouch IV family; confirm with the technical department) |
| Gauge | 18G (green colour coding, according to ISO 10555-5) |
| Size (diameter x length) | 1.0 x 32 mm (1 1/4″) |
| Reference flow rate | High, 18G series (≥ 81 ml/min according to family data; verify IFU for 32 mm) |
| Cannula material | Polyurethane (PUR) thermosensitive, biocompatible and radiopaque |
| Safety system | Passive needlestick protection (SafeTouch), automatic and irreversible activation |
| Design | Straight, without wings; transparent body for flashback verification |
| Injection port | No (there are variants with wings and with Y-type port in the same family) |
| Composition | Latex-free and PVC-free |
| Sterility / use | Sterile, single-use, in individual blister |
| Presentation | Box of 50 units |
| Indications | Intravenous injection, infusion and transfusion |
| Regulatory classification | CE Class IIa medical device; conforming to ISO 10555-5, ISO 7864 and ISO 23908 |
SafeTouch range without wings available at Cahnos:
| Reference | Gauge / Size |
|---|---|
| NIC-SF-1650P-ET | 16G x 50 mm (2″) |
| NIC-SF-1832P-ET | 18G x 32 mm (1 1/4″) — this product |
| NIC-SF-1850P-ET | 18G x 50 mm (2″) |
| NIC-SF-2032P-ET | 20G x 32 mm (1 1/4″) |
| NIC-SF-2050P-ET | 20G x 50 mm (2″) |
| NIC-SF-2225P-ET | 22G x 25 mm (1″) |
| NIC-SF-2232P-ET | 22G x 32 mm (1 1/4″) |
| NIC-SF-2419P-ET | 24G x 19 mm (3/4″) |
| NIC-SF-2425P-ET | 24G x 25 mm (1″) |
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer (Nipro) that cross-references the reference NIC-SF-1832P-ET with specific codes from other brands as direct 1:1 equivalents. After verifying official manufacturer catalogues and authorised distribution sources, the following safety catheters of 18G gauge and 32 mm length are identified, with which it shares clinical function, gauge and material:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Terumo | Surshield™ Versatus-WP, 18G x 32 mm | SR+DS1832PD | Comparable by category (not interchangeable 1:1) | Same 18G gauge (1.3 x 32 mm), polyurethane cannula and green colour, in a box of 50 units; it differs by incorporating wings and a Y-type injection port (this reference is straight without wings) and by its needle guard type safety mechanism. Code verified in authorised Terumo distribution sources. |
| B. Braun | Introcan Safety®, 18G x 1 1/4″ PUR, straight | 4251687-02 | Comparable by category (not interchangeable 1:1) | 18G x 1 1/4″ (32 mm) in polyurethane with automatic passive protection; it differs in the locking mechanism (passive shielding clip versus the SafeTouch protector) and in the needle diameter. Code located in authorised distribution listings; confirm in the official B. Braun catalogue before any substitution. |
At category level, the product is also comparable with 18G peripheral safety catheters from BD (Insyte™ Autoguard™ and Nexiva™ lines) and Vygon (Leader-Cath® family), whose specific codes must be checked in the official technical data sheet of each manufacturer before any substitution. Always verify gauge, length, cannula material (polyurethane versus Vialon or other polymers), type of safety mechanism (active/passive), presence of wings or port, and presentation per box. There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; consult the technical department before use in tenders.
5. Selection tips and variants of interest
The 18G gauge (green) with a length of 32 mm is an ideal choice for medium-duration accesses in adult patients with medium-calibre veins or for situations requiring a high flow rate: surgery, emergency, administration of blood and blood products, or high-viscosity fluids. Its 32 mm (1 1/4″) length is the most commonly used standard measure in routine peripheral cannulation.
Within the same SafeTouch IV family from the manufacturer (straight, without wings), if you require greater intravascular length, the 18G x 50 mm is available (ref. NIC-SF-1850P-ET); for even higher flow rates, move up to the 16G x 50 mm (ref. NIC-SF-1650P-ET). If your protocol requires greater fixation, the same line offers the winged variant of the same gauge and length (ref. NIC-SF-1832PW-ET) and, if you need to administer additional medication without reconnections, the version with wings and Y-type injection point (ref. NIC-SF-1832PWP-ET). For finer veins (paediatrics, geriatrics), consider the 22G and 24G gauges from the same series. Always check the integrity of the sterile packaging and the expiry date before each use, use the device only once and dispose of it in an approved container for sharp healthcare waste.




Reviews