Description
Precision lighting for medical and technical equipment
The reflector halogen lamp Philips 6423FO (EFR) is the original spare part that guarantees maximum performance in medical electronics, projection and photo laboratory equipment that require a powerful, stable light source with high colour fidelity. With its 50 mm R50 reflector and precise beam optics, it provides a constant luminous flux in clinical and technical environments where every detail matters. It is the ideal solution for replacing the original lamp of your equipment while maintaining its exact performance.
How it works and why it is the right technical choice
The regenerative cycle halogen technology allows this lamp to maintain a stable luminous flux throughout its service life, with a warm light of 3380K and a colour rendering index (CRI) of 100 that ensures tissues, surfaces and colours are perceived with complete naturalness. Its low-voltage (15V) bipin GZ6.35 cap and integrated R50 reflector allow precise focusing of the light, while its dimmable design offers intensity control according to the needs of each procedure. The dichroic reflector dissipates heat towards the rear of the optical system, protecting the equipment components.
Technical specifications
| Manufacturer / Model | Philips 6423FO (EFR A1/232) |
| EOC / EAN reference | 871150040971360 |
| Lamp type | Halogen with R50 reflector (dichroic reflector) |
| Voltage | 15 V |
| Power | 150 W |
| Base | GZ6.35 (bipin) |
| Diameter | 50 mm |
| Total length | 42 mm |
| Colour temperature | 3380K (warm white) |
| CRI | 100 (precise colour rendering) |
| Luminous flux | 840 lumens |
| Duration | 50 hours |
| Dimmable (dimmer) | Yes |
| Max. cap temperature | 400 °C |
| Max. bulb temperature | 900 °C |
| Presentation | 1CT/10X5F |
| Applications | 8mm projection, photo laboratory, medical electronics, dentistry, endoscopy |
Equivalences and cross-references
The Philips 6423FO (EFR A1/232) lamp may appear on the market coded under the order reference 871150040971360 or the Philips code 31490-6, all of which are the same product. As an EFR 15V 150W reflector lamp, it is also identified by the import codes JCR15V-150W, PN201 and 522. It is interchangeable with spare parts of the same standard from other manufacturers, always checking voltage (15V), power (150W), cap (GZ6.35) and reflector diameter (50 mm).
Within the Cahnos catalogue, it is part of a family of medical electronics halogen lamps, among which the following stand out:
| Reference Cahnos | Model | Power / Voltage | Base |
| OSR64657-LM | Philips 6423FO | 150W / 15V | GZ6.35 (R50) |
| OSR15150-LM | Philips 6834FO | 100W / 12V | GZ6.35 (MR16) |
| OSR3210-LM | Philips 7158XHP | 150W / 24V | G6.35 |
Selection tips and variants of interest
Before replacing the lamp, confirm that your equipment operates at 15V and accepts a GZ6.35 cap, as well as the reflector diameter (R50 of 50 mm) and length (42 mm) to ensure the correct fit in your device. It must not be replaced with 6V, 12V or 24V lamps without checking equipment compatibility. Always handle the bulb with gloves or a clean, dry cloth: fingerprints or grease drastically reduce the service life of the halogen lamp. Carry out the replacement with the equipment switched off and cold. If your equipment accepts lower power while retaining the cap, you may consider the Philips 6834FO 100W (ref. OSR15150-LM); for 24V configurations without reflector, the 7158XHP range (ref. OSR3210-LM). Our technical-commercial team is at your disposal to advise you on selecting the exact spare part for your equipment fleet.





Reviews