Description
Precision replacement for your anal speculum bulb and diagnostic equipment
Keep your instruments always operational with this replacement XHL xenon halogen bulb of 3.5 V, the spare part indicated for the head or bulb of the separable and divaricable anal speculum. It is the same lamp that equips the Finoff alpha+ and Glaucotest transilluminators and the F.O.4 fibre-optic laryngoscope handles, making it the ideal solution for hospitals, clinics and practices that need to quickly and reliably replace the light source of their equipment without replacing the complete instrument.
Technical explanation: XHL xenon-halogen technology
This bulb uses XHL technology (xenon halogen), which combines xenon gas with the halogen cycle to offer high luminous performance in a compact format. The result is a white, bright and stable light that allows faithful appreciation of tissue colour in each examination, without shadows or flickering. Operating at low voltage (3.5 V), consumption is reduced and the heat generated is lower, which protects the head and the optical housing of the instrument. Its screw base ensures a firm seat and quick replacement without tools, minimising downtime of the clinical equipment.
Technical specifications
The characteristics of the replacement XHL xenon halogen bulb of 3.5 V (ref. Cahnos 500028566) are detailed below:
| Characteristic | Value |
|---|---|
| Lamp type | XHL xenon halogen replacement bulb |
| Voltage | 3.5 V |
| Consumption | Approx. 0.7 A |
| Approximate power | 2.45 W |
| Base / cap | 8-32 UNC thread (Heine XHL standard) |
| Total length | 18 mm |
| Maximum diameter | 5.5 mm |
| Indicative average life | Approx. 20 hours of use |
| Technology | Xenon halogen XHL |
| Light tone | Bright and stable white |
| Manufacturer reference | Heine X-002.88.044 (XHL #044 bulb) |
| Compatibility | Bulb for divaricable anal speculum, Finoff alpha+ and Glaucotest transilluminators, and F.O.4 NT, F.O.4 SLIM NT, F.O.4 SHORT NT and angled F.O. laryngoscope handles |
Main applications: scleral transillumination (Finoff alpha+, Glaucotest), laryngoscopy with F.O.4 fibre-optic handles and examination with bulb for divaricable anal speculum.
Equivalences and cross-references
This bulb corresponds to the Heine XHL #044 lamp, original reference X-002.88.044 (also cited as X-02.88.044 and X00288044). On the market it is also known by the alternative codes CL889 / CL-889 and CA889 / CA-889, as well as by the Propper reference 199405 and the EAN 4053755143801. It shares a platform with the rest of the XHL series lamps of 3.5 V, so in many handles it is interchangeable with the Heine #049 and #051 variants depending on the specific instrument.
In the Cahnos catalogue, this same XHL bulb of 3.5 V is available associated with different equipment: 500028561 (F.O.4 SLIM NT handle), 500028562 (standard F.O.4 NT handle), 500028563 (Glaucotest), 500028564 (Finoff alpha+), 500028565 (Heine diagnostic lamp), 500028567 (angled F.O. handle) and 500028568 (F.O.4 SHORT NT). It should not be confused with the XHL lamps of 2.5 V from the same series (Heine models #035, #037, #038, #041, #042 and #056), used in otoscopes and other examination instruments with lower power supply.
Selection tips and variants of interest
- Before replacing the bulb, verify that your handle or head operates at 3.5 V; do not use this reference in 2.5 V equipment.
- Check the model of your equipment: bulb for divaricable anal speculum, Finoff alpha+ or Glaucotest transilluminator, or standard F.O.4 handle (NT), slim (SLIM NT), short (SHORT NT) or angled F.O., and select the specific reference for your instrument.
- Handle the bulb with gloves or a clean, dry cloth; direct contact with fingers can damage the glass and shorten its service life.
- Periodically check the condition of the head housing and the handle contacts to ensure optimal luminous performance.
- For intensive use, consider upgrading to long-lasting LED lighting modules, available as an alternative to XHL bulbs in compatible instruments.