Replacement LED bulb 3.7 V for E-SCOPE® Ophthalmoscope · Ref. 31563 (GM31563)

128,25 €

Original 3.7 V LED bulb for E-SCOPE® ophthalmoscope, replacement reference 31563. High-efficiency lighting spare that maintains the true-colour white light (5,500 K) of the E-SCOPE® family, with low consumption, high contrast and an estimated service life of up to 20,000 hours. Essential part to ensure continuity of care in fundus examination without replacing the head. Compatible with the Riester family mounting system. Sales unit: 1 unit; class I medical device. For large orders, you may request a quote: check conditions and availability with our technical-commercial team.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM31563

Description

LED bulb 3.7 V for E-SCOPE® Ophthalmoscope (Ref. 31563)

1. Introduction

This 3.7 V LED bulb is the original lighting replacement for the E-SCOPE® family ophthalmoscope (Ref. 31563, SKU GM31563). Designed and manufactured, it restores the complete optical performance of the head without the need to purchase a new instrument. It is the wear part recommended by the manufacturer for general medicine, paediatrics, ophthalmology and ear, nose and throat (ENT) practices working with the E-SCOPE® range, ensuring continuity of care and clear, reliable fundus examination.

2. Technical Explanation

The 3.7 V LED bulb generates the innovative illumination of the E-SCOPE® family: true-colour white light at 5,500 K that supports high-contrast diagnostics and very faithful colour reproduction of the retina, optic disc and vasculature. Thanks to LED technology, it offers a long estimated service life of up to 20,000 hours and very low consumption: the E-SCOPE® lighting system achieves up to 50 hours of operation thanks to the integrated IPC converter, which regulates the voltage of AA batteries to the optimal voltage required by the LED.

As a lighting replacement, handling is simple and requires no special tools, following the manufacturer’s instructions. It is recommended not to touch the LED glass with fingers when installing it to avoid shortening its service life, and to keep a spare unit in stock to avoid interrupting clinical activity.

3. Technical Specifications

Product data

Manufacturer GIMA
Manufacturer reference 31563
Reference Cahnos (SKU) GM31563
Family E-SCOPE®
Sales unit 1 pc (1 unit)
Device type Medical device
Device class I

Technical features

Bulb type Replacement LED for ophthalmoscope
Voltage 3.7 V
Application E-SCOPE® Ophthalmoscope (E-SCOPE® family heads)
Lighting technology True-colour white light LED (5,500 K)
Estimated LED service life Up to 20,000 hours
Consumption / battery life Up to 50 hours of operation with AA batteries via integrated IPC converter (regulates battery voltage to the optimal LED voltage)
Fixation system Compatible with the Riester family attachment system

Available references

Reference Description Sales unit
GM31563 LED bulb 3.7 V (E-SCOPE® OPHTHALMOSCOPE BULB LED 3.7V) 1 pc

4. Equivalences and Cross-References

This 3.7 V LED bulb corresponds to the manufacturer’s official coding (Ref. 31563) for the E-SCOPE® ophthalmoscope. Within the same E-SCOPE® family, the following related references are documented:

Reference Product Observations
31562 (GM31562) Xenon bulb 2.5 V for E-SCOPE® ophthalmoscope Lighting variant with different voltage and technology (xenon versus LED); not interchangeable 1:1
31564 (GM31564) E-SCOPE® otoscope-ophthalmoscope set with 3.7 V LED illumination in rigid case Complete unit using the same 3.7 V LED lighting system

The mounting system of the E-SCOPE® family is compatible with Riester range accessories: reusable autoclavable ear specula (refs. GM31816 to GM31821, Ø 2 to 5 mm) and single-use disposable specula (e.g., model R, 4 mm, ref. 2471040B). No 1:1 equivalences validated by the manufacturer with bulbs from other commercial brands have been identified for this reference; any substitution must be validated in advance with the technical-commercial department of Cahnos.

5. Selection tips and variants of interest

Always check the reference engraved on the bulb or in your equipment documentation before ordering the replacement: Ref. 31563 corresponds to the 3.7 V LED bulb of the E-SCOPE® ophthalmoscope, while Ref. 31562 is the 2.5 V xenon variant of the same ophthalmoscope. Keep a spare bulb in the practice to avoid interrupting examinations in case of lighting failure. If your facility has the E-SCOPE® kit (Ref. 31564), this replacement ensures correct functioning of the ophthalmoscopic part. For institutional orders, tenders or compatibility queries, contact the technical-commercial team of Cahnos. For large orders, you may request a quote.

Additional information

Manufacturer reference

31563

Family

E-SCOPE®

Product type

Replacement LED bulb for ophthalmoscope

Voltage

3.7 V

Lighting technology

True-colour white light LED (5,500 K)

LED service life

Up to 20,000 hours

Battery life

Up to 50 hours with AA batteries via integrated IPC converter

Compatibility

E-SCOPE® ophthalmoscope from · Fixation system compatible with the Riester family

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

I

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityMultilingüe PDF
📜 ISO 9001 / 13485 certificatesDownload PDF

Reviews

There are no reviews yet.

Be the first to review “Replacement LED bulb 3.7 V for E-SCOPE® Ophthalmoscope · Ref. 31563 (GM31563)”

Your email address will not be published. Required fields are marked *