Description
1. Commercial Introduction
The Fiocchetti MEDIKA 500 refrigerator is the high-capacity professional solution from the MEDIKA® series for the safe storage of medicines, vaccines, sera, diagnostic kits and heat-sensitive biological material at positive temperature. In column format with 500 nominal litres (527 net litres), its tempered glass door allows the contents to be viewed without opening the chamber, reducing cold loss and speeding up stock control in the pharmacy office and vaccination rooms.
Designed especially for pharmacies, hospital departments, clinical studies, aesthetic, dental and ophthalmological centres, laboratories and the pharmaceutical industry, it complies with current international standards and offers the possibility of customising the internal configuration. Manufactured in Italy by Fiocchetti Scientific S.r.l., it is marketed on a quotation basis: the manufacturer configures each unit to order.
2. Technical explanation of the equipment
The MEDIKA® series combines robust, hygienic construction with advanced traceability features. The structure is made of steel with antibacterial plasticised PVC in white on the inside and outside, with the option of an internal chamber in 18/10 AISI 304 stainless steel, rounded corners and a chamber with a base. It incorporates 4 unidirectional wheels for easy mobility and two front feet for maximum stability.
The tempered glass door complies with the IEC 61010-1 safety standards, is anti-fog and low-emissivity on an aluminium frame, with a magnetic gasket for an airtight seal, automatic closing when the opening angle is less than 90° and reversible opening. The insulation is high-density injected polyurethane foam (43 kg/m³), CFC-free and with ecological water injection, with a thickness of 75 mm at the rear and 60 mm at the sides.
The unit features professional ventilated refrigeration, which ensures a uniform and stable distribution of cold, and adaptive automatic defrosting with evaporation of the condensate. It includes full LED interior lighting along the entire height of the chamber with intensity adjustment, Night & Day energy-saving function and eco-friendly R290 refrigerant gas, with a consumption of only 1 kWh/24h and a noise level below 45 dBA.
The electronic controller offers temperature display and configuration with a resolution of 0.1 °C and an accuracy of ±0.3 °C, a backlit alphanumeric LCD screen of 16 characters customisable in 5 languages and a 4-membrane keypad with a customisable password. It is available in three levels: ECT-F (three types of temperature alarms and recording of 12 events), ECT-F PLUS (backup battery of up to 48 h in the event of power cuts, recording of minimum/maximum temperatures and a clean contact for remote alarm) and ECT-F TOUCH (7″ touch screen with real-time graph, SD card, USB port, SIM port, integrated Web Server LAN RJ45, MODBUS TCP/IP and integration with local and cloud monitoring systems).
3. Technical Specifications
3.1. Structure and refrigeration
| Parameter | Specification |
| Brand / Manufacturer | Fiocchetti Scientific S.r.l. |
| Series | MEDIKA® (positive temperature, glass door) |
| Temperature range | +2 / +15 °C |
| Nominal capacity | 500 L (17.65 cu ft) |
| Net capacity | 527 L (18.61 cu ft) |
| Internal dimensions | 60 x 58 x 150 cm |
| External dimensions (HxDxW) | 72 x 76 x 208 cm |
| Insulation type | High-density injected polyurethane foam (43 kg/m³), CFC-free and with ecological water injection |
| Insulation thickness | 75 mm rear / 60 mm sides |
| Structure | Steel with white antibacterial plasticised PVC (interior/exterior) or interior option in 18/10 AISI 304 steel; rounded corners and chamber with a base |
| Mobility | 4 unidirectional wheels + 2 front stability feet |
| Door | Tempered glass IEC 61010-1, anti-fog and low emissivity on an aluminium frame; magnetic gasket; automatic closing <90°; reversible opening |
| Internal lighting | Full LED across the full height of the chamber, with intensity adjustment |
| Cooling type | Professional ventilated |
| Defrosting type | Adaptive automatic with condensate evaporation |
| Energy saving | Night & Day function |
3.2. Electronic controller
| Parameter | Specification |
| Available controllers | ECT-F / ECT-F PLUS / ECT-F TOUCH |
| Display | Backlit alphanumeric LCD screen of 16 characters, customisable in 5 languages; screen configurable in four reading modes (ECT-F / ECT-F PLUS); 7″ touch screen (ECT-F TOUCH) |
| Resolution / accuracy | 0.1 °C / ±0.3 °C |
| Keyboard | 4 membrane keys with password protection (on-off and setpoint) |
| Alarms (ECT-F) | Three types of temperature alarms and 12-event recording |
| ECT-F PLUS | Backup battery for power cut alarm (up to 48 h), recording of minimum/maximum temperature and clean contact for remote alarm |
| ECT-F TOUCH | SD card with data history, USB port for download and update, SIM port (optional GSM module), integrated Web Server (LAN RJ45) and MODBUS TCP/IP; anti-freeze and anti-overheating protection; dry contact for remote alarm; silencable acoustic and visual alarms with automatic recording |
3.3. Technical data of the refrigerator
| Parameter | Value |
| Refrigerant gas type | R290 |
| Consumption | 1 kWh/24h |
| Absorbed power | kW 0.17 / Amp 1 |
| Starting absorption | Amp 3 |
| Noise level | <45 dBA |
| Heat output EN 12900 | 40 W |
| Max. no. of shelves | 7 (shelf dimensions: cm 56×55) |
| Max. no. of drawers | 14; with dividers (LxDxH): cm 15x50x7.5 (3 spaces); without dividers: cm 49x50x7.5 |
3.4. Available references
| Model | Fiocchetti code | Controller | Temperature range | Capacity | External dimensions (HxDxW) |
|---|---|---|---|---|---|
| MEDIKA 500 ECT-F | MED0501 | ECT-F | +2 / +15°C | 527 L (18.61 cu ft) | 72 x 76 x 208 cm |
| MEDIKA 500 ECT-F PLUS | MED0503 | ECT-F PLUS | +2 / +15°C | 527 L (18.61 cu ft) | 72 x 76 x 208 cm |
| MEDIKA 500 TOUCH | MED0502 | ECT-F TOUCH | +2 / +15°C | 527 L (18.61 cu ft) | 72 x 76 x 208 cm |
4. Equivalences and Cross-References
The three versions in this datasheet (MED0501 ECT-F, MED0503 ECT-F PLUS and MED0502 TOUCH) belong to the same MEDIKA 500 platform from the manufacturer and share the cabinet, a net capacity of 527 litres, dimensions (72 x 76 x 208 cm) and temperature range (+2/+15 °C); they differ exclusively in the electronic controller and its recording, alarm and monitoring features. They therefore constitute exact reference equivalences within the same manufacturer, and the choice should be made according to the level of traceability required by the facility.
Within the manufacturer’s own range, the MEDIKA 2T 1000 series comprises two MEDIKA 500 refrigerators (references MED0501/MED0503/MED0502 x2) to offer independent dual positive temperature (1,054 litres net, dimensions 144 x 76 x 208 cm). The LABOR series offers the same positive temperature concept with a solid door in comparable capacities, and the EMOTECA series configures the same platform as a blood bank at +4 °C. For smaller volumes with a glass door, the MEDIKA 400 series (MED0401/MED0403/MED0402, 347 L net) offers the same concept; for larger capacity, the MEDIKA 700 series (MED0701/MED0703/MED0702, 620 L net).
There is no manufacturer-validated equivalence table cross-referencing this reference with specific codes from other brands; consult the technical department before use in tenders. At category level, in the segment of large-volume refrigerators for pharmacy and vaccine cold chain with glass door, the homologous families of Liebherr (MediLine / Pharmacare range), Kirsch, Gram Commercial, Dometic Medical, B Medical Systems, Haier Biomedical and PHC Europe stand out. Before any substitution between brands, the following must be verified field by field: net useful capacity, actual thermal range, door type, climate class, refrigerant gas, installation dimensions and alarm and recording features.
5. Selection tips and variants of interest
Choose the controller according to your traceability needs: the ECT-F covers basic storage with three types of temperature alarm and recording of 12 events; the ECT-F PLUS adds a 48 h backup battery for power cuts, minimum/maximum recording and a clean contact for remote alarm —key in pharmacy and vaccine cold chains without continuous supervision—; the ECT-F TOUCH is the hospital option for integration with local and cloud monitoring systems, with real-time graphical recording and data export via SD card, USB or LAN network (MODBUS TCP/IP). For vaccine storage, the ECT-F PLUS or TOUCH version is recommended, along with thermal validation of the equipment according to the centre’s protocol.
Check the installation space: the unit occupies 72 x 76 x 208 cm (width x depth x height); confirm door passage and leave adequate lateral and rear ventilation for optimal performance. The internal configuration is customisable and adjustable in height: the unit can be completed with additional shelves (up to 7 of 56×55 cm), removable drawers with or without dividers (up to 14), a lockable narcotics drawer, a wheel kit with brakes and Fiocchetti monitoring accessories (electronic lock, acoustic and visual power-failure alarm, DMLP TOUCH module, GSM and Wi-Fi modules, external terminal box and local and cloud monitoring systems), all available on request. Sale is made on quotation: contact the technical-commercial team at Cahnos for configuration and offer.