Fiocchetti MEDIKA 2T 400 two-temperature refrigerator | 330 L net, +2/+15 °C, double compartment and tempered glass doors | Ref. FIO-MEDIKA-2T-400 (MET0401 / MET0403 / MET0402)

Price on request

Heavy / bulky product. Shipping is neither free nor included in the price: it depends on the destination, Cahnos subsidises part of it and we will confirm the cost separately after your order. If you need it before buying, please contact us.

Professional double-compartment positive-temperature pharmacy refrigerator, the best seller of the Fiocchetti MEDIKA 2T series. With 400 nominal litres (200+200) and 330 net litres, two independent refrigeration units and two anti-fog tempered glass doors, it allows medicines and vaccines to be stored simultaneously in two configurable temperature ranges between +2 and +15 °C. Ventilated refrigeration, automatic defrosting, Full LED lighting, high-density polyurethane insulation and ecological R290 gas with consumption of 1.4 kWh/24h. Available in three controller levels (ECT-F, ECT-F PLUS and ECT-F TOUCH) depending on the required traceability and monitoring. Italian manufacture; sale on quotation.

International shipping. Import duties and taxes are payable by the recipient.

Reference
FIO-MEDIKA-2T-400

Description

1. Commercial Introduction

The Fiocchetti MEDIKA 2T 400 Refrigerator is the best-selling medium model in the MEDIKA 2T pharmacy series: a double-compartment unit with two independent refrigeration units offering 400 nominal litres (200+200) and 330 net litres, designed to store medicines and vaccines at two different positive temperatures simultaneously. Its two tempered glass doors allow the contents to be viewed without opening the chamber, reducing cold loss and facilitating daily visual control, a decisive factor in the pharmacy setting. Designed in accordance with international standards and the official pharmacopoeia, it is supplied in three controller versions (ECT-F, ECT-F PLUS and ECT-F TOUCH) to suit the level of traceability and monitoring required by each facility. Italian manufacture; sale by quotation with custom configuration.

2. Technical explanation of the equipment

The MEDIKA 2T series is characterised by integrating two independent compartments with two separate refrigeration units, which allows two different positive temperature regimes to be maintained without interference between chambers, each adjustable between +2 °C and +15 °C, with a resolution of 0.1 °C and accuracy of ±0.3 °C.

The doors are made of tempered glass in accordance with safety standard IEC 61010-1, anti-fog low-emissivity in an aluminium frame, with a long anodised aluminium handle, magnetic gasket for a tight seal, automatic closing at an angle below 90° and reversible opening. The structure is steel with white antibacterial plasticised PVC (with optional 18/10 AISI 304 stainless steel interior), rounded corners, chamber with bottom, 4 unidirectional castors and two front stabilising feet.

The unit features professional fan-assisted refrigeration, which ensures uniform temperature distribution throughout each chamber volume, and adaptive automatic defrost with condensate evaporation, without downtime. It includes full-height interior LED lighting with intensity adjustment, Night & Day energy-saving function, high-density injected polyurethane foam insulation (43 kg/m³, 70 mm rear / 50 mm side) and ecological refrigerant gas R290.

Electronic controllers available

ECT-F: backlit alphanumeric LCD display with 16 customisable characters in 5 languages, 4-membrane keypad with password, three types of temperature alarms and a 12-event log.

ECT-F PLUS: adds a backup battery for power failure alarm up to 48 hours, minimum/maximum temperature recording and a clean contact for remote alarm, key in vaccine cold chains.

ECT-F TOUCH: 7″ touchscreen with real-time graph, ports for SD card, USB and SIM (optional GSM module), integrated Web Server (LAN RJ45), MODBUS TCP/IP, anti-freeze and anti-overheating protection and a dry contact for remote alarm, with integration into local and cloud monitoring systems.

3. Technical Specifications

Structure and refrigeration

Parameter Specification
Manufacturer / Series Fiocchetti, MEDIKA 2T series (dual positive temperature)
Temperature range +2/+15 °C | +2/+15 °C (configurable per compartment)
Nominal capacity 200+200 lt (7.06 + 7.06 cu ft)
Net capacity 170+160 lt (6.01 + 5.66 cu ft) · total 330 lt
Internal dimensions 50 x 48.5 x 68.5 / 50 x 48.5 x 73 cm
External dimensions (HxDxW) 60 x 66 x 202 cm
Insulation type High-density injected polyurethane foam (43 kg/m³), CFC-free and with ecological water injection
Insulation thickness 70 mm rear / 50 mm on the sides
Structure Steel with white antibacterial plasticised PVC (interior/exterior) or optional 18/10 AISI 304 stainless steel interior; rounded corners and chamber with bottom
Doors 2 anti-fog tempered glass doors (IEC 61010-1), magnetic gasket, automatic closing <90° and reversible opening
Mobility 4 unidirectional wheels + 2 front stability feet
Internal lighting Full LED across the full height of the chamber, with intensity adjustment
Cooling type Professional ventilated
Defrosting type Adaptive automatic with condensate evaporation
Energy saving Night & Day function

Technical data of the refrigerator

Parameter Value
Refrigerant gas type R290
Consumption 1.4 kWh/24h
Absorbed power kW 0.17+0.17 / Amp 1+1
Starting absorption Amp 3+3
Noise level <50 dBA
Heat output EN 12900 W 58
Max. no. of shelves 3+3 (dimensions cm 46×45)
Max. no. of drawers 5+5 (with dividers LxDxH: cm 11.8x40x7.5, 3 spaces; without dividers: cm 39x40x7.5)
Max. no. of stainless steel wire drawers 5+5 (internal dimensions LxDxH: cm 43.5×40.5×6.2)

Available references

Model Fiocchetti code Controller Temperature range Capacity External dimensions (HxDxW)
MEDIKA 2T 400 ECT-F MET0401 ECT-F +2/+15°C | +2/+15°C 358 L (12.64 cu ft) 60 x 66 x 202 cm
MEDIKA 2T 400 ECT-F PLUS MET0403 ECT-F PLUS +2/+15°C | +2/+15°C 358 L (12.64 cu ft) 60 x 66 x 202 cm
MEDIKA 2T 400 TOUCH MET0402 ECT-F TOUCH +2/+15°C | +2/+15°C 358 L (12.64 cu ft) 60 x 66 x 202 cm

4. Equivalences and Cross-References

The three versions on this sheet (MET0401 ECT-F, MET0403 ECT-F PLUS and MET0402 TOUCH) belong to the same Fiocchetti MEDIKA 2T 400 platform and share the cabinet, double compartment, two refrigeration units, external dimensions (60 x 66 x 202 cm), capacity and temperature range (+2/+15 °C in both sections); they differ exclusively in the electronic controller and its recording, alarm and monitoring features. The choice should be made according to the level of traceability required by the facility.

Within the same manufacturer, the MEDIKA 2T series offers the same dual positive temperature concept with glass door in other capacities; and the LABOR 400 series (LAB0401/LAB0403/LAB0402) offers approximately the same capacity (347 net litres) with a solid door, ideal if light exposure is to be avoided. For combined positive cold + freezing storage, the LABOR 2T series (LAD0281/83/82, LAD0401/03/02, LAD0501/03/02, LAD0701/03/02) covers the dual regime +2/+15 °C and -10/-25 °C (down to -30 °C on the 2T 700).

There is no manufacturer-validated equivalence table cross-referencing this reference with other brands; consult the technical department before using it in tenders. At category level, in the segment of double-temperature pharmacy and vaccine refrigerators with glass door and electronic control with alarms, comparable families from Liebherr (MediLine range and pharmacy refrigerators), Kirsch, Gram Commercial, Dometic Medical, B Medical Systems, Haier Biomedical and PHC Europe stand out. Before any substitution between brands, the following must be checked one by one: net usable capacity per compartment, actual thermal range, door type, climatic class, refrigerant gas, installation dimensions and alarm and recording features.

5. Selection tips and variants of interest

Choose the controller according to your traceability needs: the ECT-F covers basic storage with three alarm types and a 12-event log; the ECT-F PLUS adds a 48-hour backup battery for power cuts, key in vaccine cold chains without guaranteed electricity supply; the ECT-F TOUCH is the option for integration with local and cloud monitoring systems, with real-time graphical recording and data export via SD card, USB or LAN network (MODBUS TCP/IP).

Check the installation space: the unit occupies 60 x 66 x 202 cm (width x depth x height); confirm door passage and adequate side and rear ventilation for optimum performance.

Use in pharmacy and vaccines: the double compartment allows separating medicines that require different storage temperatures within the range +2/+15 °C, or reserving one compartment for vaccines and another for pharmaceuticals; for vaccine storage, the ECT-F PLUS or TOUCH version is recommended for continuous recording and remote alarm, and thermal validation and equipment qualification should be carried out according to the centre’s protocol.

Customisable internal configuration: the unit can be completed with additional shelves, removable drawers and stainless steel wire drawers, as well as Fiocchetti monitoring accessories (electronic lock, acoustic and visual power failure alarm, DMLP TOUCH module, GSM and Wi-Fi modules and local and cloud monitoring systems), all available on request. Sale is made on quotation: Fiocchetti configures each unit to measure; contact the technical-commercial team at Cahnos for configuration and quotation.

Additional information

Product line

MEDIKA 2T

Controlador

ECT-F, ECT-F PLUS, ECT-F TOUCH

Capacity

358 L (12.64 cu ft)

Dimensions

60 x 66 x 202 cm

Manufacturer

Fiocchetti (Italian manufacture)

Set type

Double-compartment, dual-refrigeration-unit refrigerator for pharmacy

Temperature range

+2/+15 °C, +2/+15 °C

Nominal capacity

200+200 litres (400 litres)

Net capacity

170+160 litres (330 litres total)

External dimensions

60 x 66 x 202 cm (W x D x H)

Internal dimensions

50 x 48.5 x 68.5 / 50 x 48.5 x 73 cm

Cooling type

Professional ventilated

Defrosting type

Adaptive automatic with condensate evaporation

Refrigerant gas

R290

Energy consumption

1.4 kWh/24h

Door type

2 anti-fog tempered glass doors (IEC 61010-1), automatic closing

Available controllers

ECT-F (MET0401) / ECT-F PLUS (MET0403) / ECT-F TOUCH (MET0402)

Insulation

High-density injected polyurethane foam (43 kg/m³), CFC-free; 70 mm rear / 50 mm lateral

Lighting

Full LED across the full height of the chamber, with intensity adjustment

Mobility

4 unidirectional wheels + 2 front stability feet

Alarms

Temperature alarms, 12-event recording; optional 48 h backup battery and remote alarm (ECT-F PLUS/TOUCH)

Regulatory standard

International standards and official pharmacopoeia

Documentation

Reviews

There are no reviews yet.

Be the first to review “Fiocchetti MEDIKA 2T 400 two-temperature refrigerator | 330 L net, +2/+15 °C, double compartment and tempered glass doors | Ref. FIO-MEDIKA-2T-400 (MET0401 / MET0403 / MET0402)”

Your email address will not be published. Required fields are marked *

You may also like…