Description
1. Commercial Introduction
The Fiocchetti MEDIKA 2T 1000 dual-temperature refrigerator is the professional dual-chamber solution for the safe storage of medicines, vaccines and thermosensitive biological material. It consists of two independent biological refrigerators of 500 litres each, with two opposite glass doors, two displays and positive temperatures. Designed especially for pharmacies, hospital pharmacies, hospital departments, clinical studies and health centres, it allows maintaining two distinct positive temperature regimes for products that must be stored at different temperatures, complying with international standards and the official pharmacopoeia.
2. Technical explanation of the equipment
The MEDIKA 2T® series is characterised by a double compartment with an independent refrigerating unit for each chamber, allowing medicines and vaccines to be kept at two different positive temperatures without interference between compartments. The two doors are made of tempered glass in accordance with the IEC 61010-1 safety standards, anti-fog and low emissivity on an aluminium structure, with a long anodised aluminium handle, magnetic gasket for an airtight seal and automatic closing when the opening angle is less than 90°, allowing the contents to be viewed without opening the chamber and reducing thermal losses.
The structure is made of steel with white antibacterial plasticised PVC on the inside and outside, with the option of an interior chamber in 18/10 AISI 304 stainless steel, rounded corners and a chamber with a base. It includes 4 unidirectional wheels for easy mobilisation and two front feet for maximum stability. The insulation is high-density injected polyurethane foam (43 kg/m³), CFC-free and with ecological water injection, with a thickness of 75 mm at the rear and 60 mm on the sides.
Both chambers feature professional ventilated refrigeration, which ensures a uniform and stable distribution of cold, and adaptive automatic defrosting with evaporation of the condensate. It includes full LED interior lighting along the entire height of the chamber with intensity adjustment and the Night & Day energy-saving function. It uses ecological refrigerant gas R290.
Depending on the version chosen, the unit incorporates one of these controllers: ECT-F (backlit alphanumeric LCD display of 16 characters customisable in 5 languages, resolution of 0.1 °C and accuracy of ±0.3 °C, 4-membrane keypad with customisable password, three types of temperature alarms and recording of 12 events), ECT-F PLUS (adds backup battery for power failure alarm up to 48 h, minimum/maximum temperature recording and clean contact for remote alarm) or ECT-F TOUCH (7″ touch screen, real-time graph, SD card, USB port, SIM port, integrated Web Server LAN RJ45 and MODBUS TCP/IP, anti-freeze and anti-overheating protection, dry contact for remote alarm and compatibility with local and cloud monitoring systems).
3. Technical Specifications
Structure and refrigeration
| Temperature range | +2 °C / +15 °C | +2 °C / +15 °C (dual chamber, adjustable) |
| Nominal capacity | 500+500 lt (17.65+17.65 cu ft) |
| Net capacity | 527+527 lt (18.61+18.61 cu ft) | 1,054 lt total |
| Internal dimensions | 60 x 58 x 150 cm (x 2) |
| Insulation type | High-density injected polyurethane foam (43 kg/m³), CFC-free, ecological water injection |
| Insulation thickness | 75 mm rear / 60 mm sides |
| Structure | Steel with white antibacterial plasticised PVC (interior/exterior) or interior option in 18/10 AISI 304 steel; rounded corners and chamber with base |
| Mobility | 4 unidirectional wheels + 2 front stability feet |
| Internal lighting | Full LED across the full height of the chamber, with intensity adjustment |
| Cooling type | Professional ventilated |
| Defrosting type | Adaptive automatic with condensate evaporation |
| Energy saving | Night & Day function |
Technical data of the refrigerator
| Refrigerant gas type | R290 |
| Consumption | 1+1 kWh/24h |
| Absorbed power | kW 0.17 + 0.17 / Amp 1 + 1 |
| Starting absorption | Amp 3 + 3 |
| Noise level | <45 dBA |
| Heat output EN 12900 | W 40+40 |
| Max. no. of shelves | 7+7 (dimensions cm 56×55) |
| Max. no. of drawers | 14+14 (with dividers: cm 15x50x7.5, 3 spaces; without dividers: cm 49x50x7.5) |
| Controller | ECT-F / ECT-F PLUS / ECT-F TOUCH; resolution 0.1 °C, accuracy ±0.3 °C |
| Alarms | Three types of temperature alarms and recording of 12 events (depending on version) |
Available references
| Model | Fiocchetti code | Controller | Temperature range | Capacity | External dimensions (HxDxW) |
|---|---|---|---|---|---|
| MEDIKA 2T 1000 ECT-F | MED0501 (x2) | ECT-F | +2/+15°C | +2/+15°C | 1054 lt (37.22 cu ft) | 144 x 76 x 208 cm |
| MEDIKA 2T 1000 ECT-F PLUS | MED0503 (x2) | ECT-F PLUS | +2/+15°C | +2/+15°C | 1054 lt (37.22 cu ft) | 144 x 76 x 208 cm |
| MEDIKA 2T 1000 TOUCH | MED0502 (x2) | ECT-F TOUCH | +2/+15°C | +2/+15°C | 1054 lt (37.22 cu ft) | 144 x 76 x 208 cm |
4. Equivalences and Cross-References
The three variants in this data sheet (MED0501 ECT-F, MED0503 ECT-F PLUS and MED0502 TOUCH) belong to the same MEDIKA 2T 1000 family from the manufacturer and share the cabinet, net capacity of 1,054 litres, temperature range (+2/+15 °C) and the set of refrigeration features; they differ exclusively in the electronic controller and its recording, alarm and monitoring features. They are interchangeable variants with identical dimensions and capacity, and the choice should be made according to the level of traceability required by the facility.
Within the manufacturer’s own range, the MEDIKA 2T series offers the same dual positive temperature concept in the larger capacity MEDIKA 2T 1500 (MED0701/MED0703/MED0702, 1,240 net litres, dimensions 150 x 84.5 x 210 cm). For negative cold storage or combined refrigerator-freezer, the LABOR 2T series offers dual-temperature combinations (e.g. LABOR 2T 500, LAD0501/LAD0503/LAD0502).
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Bow ties | MEDIKA 2T 1000 ECT-F PLUS | MED0503 (x2) | Exact reference equivalence (same manufacturer) | Identical dimensions and capacity; adds 48 h backup battery, min/max recording and contact for remote alarm |
| Bow ties | MEDIKA 2T 1000 TOUCH | MED0502 (x2) | Exact reference equivalence (same manufacturer) | Identical dimensions and capacity; incorporates 7″ touch screen, SD/USB recording, web server and MODBUS |
| Bow ties | MEDIKA 2T 1500 | MED0701 / MED0703 / MED0702 | Comparable by category (not interchangeable 1:1) | Same dual-temperature family, larger capacity (1,240 L) and dimensions 150 x 84.5 x 210 cm |
There is no equivalence table validated by the manufacturer that cross-references this reference with specific codes from other brands; consult the technical department at Cahnos before use in tenders or specifications. At category level, in the segment of dual positive-temperature refrigerators for pharmacy and vaccine cold chain, the homologous families from Liebherr (MediLine / Pharmacare range), B Medical Systems (vaccine refrigerators with 24/7 monitoring), Haier Biomedical and PHC Europe stand out. Before any substitution between brands, the following must be verified field by field: net usable capacity, thermal range, door type, climate class, refrigerant gas, installation dimensions and alarm and recording features.
5. Selection tips and variants of interest
Choose the controller according to your traceability needs: the ECT-F covers basic storage with three types of temperature alarm and logging of 12 events; the ECT-F PLUS adds a 48 h backup battery for power cuts, minimum/maximum logging and a clean contact for remote alarm, key in pharmacy and environments without continuous supervision; the ECT-F TOUCH is the hospital option for integration with local and cloud monitoring systems, real-time graphical logging and data export via SD/USB/LAN (MODBUS TCP/IP).
Check the installation space: the unit occupies 144 x 76 x 208 cm (width x depth x height); confirm door passage and adequate ventilation for optimal performance. With 1,054 net litres in total, it is the dual-chamber solution in the series; for greater capacity consider the MEDIKA 2T 1500 (1,240 L), and for smaller volumes consult the MEDIKA positive-temperature glass-door series (from 100 to 1,500 litres).
You can complete the unit with additional shelves, pull-out drawers on telescopic guides, baskets or wire drawers in stainless steel, a lockable narcotics drawer, wheel kit with brakes, pass-through ports and Fiocchetti monitoring accessories (GSM/Wi-Fi modules, DMLP TOUCH, local and cloud monitoring systems), all available on request. Sale is made on quotation: the manufacturer configures each unit to order.






























Reviews