Description
1. Commercial Introduction
The Fiocchetti LABOR 2T 500 combined refrigerator with freezer (Ref. FIO-LABOR-2T-500) is a professional high-capacity refrigeration unit, designed to simultaneously store medicines and vaccines at positive temperature (from +2 °C to +15 °C) and temperature-sensitive products in freezing (from -10 °C to -25 °C). With two independent refrigeration units, two solid doors with lock and dual display with alarms, this two-chamber combination offers the safety, precision and traceability required by hospitals, hospital pharmacies, clinical laboratories, blood banks and health centres, complying with international standards for storage of vaccines and temperature-sensitive material. Manufactured in Italy by Fiocchetti Scientific S.r.l., it is sold on quotation: the manufacturer configures each unit to order.
2. Technical explanation of the equipment
The LABOR 2T series is characterised by integrating two independent compartments with two separate refrigeration units, allowing two different temperature regimes to be maintained simultaneously without interference between chambers: the refrigeration compartment regulates between +2 °C and +15 °C and the freezer compartment between -10 °C and -25 °C, with a resolution of 0.1 °C and an accuracy of ±0.3 °C.
Both chambers feature professional ventilated refrigeration, ensuring uniform temperature distribution throughout the volume, and adaptive automatic defrosting with evaporation of condensation water, without downtime or ice formation. The Full LED interior lighting covers the entire height of the chamber with intensity adjustment, and the unit incorporates the Night & Day energy-saving function. The two solid doors integrate a handle, magnetic gasket on all four sides, automatic lock, automatic closing at an angle of less than 90° and reversible door opening direction.
The structure is made of steel with a white antibacterial plasticised PVC finish on the inside and outside, rounded corners and a chamber with a base, on 4 unidirectional wheels and two front feet for maximum stability. The insulation is high-density injected polyurethane foam (43 kg/m³), CFC-free and with ecological water injection, with 75 mm at the rear and 60 mm on the sides, which minimises thermal losses.
Depending on the controller version chosen, the unit incorporates the ECT-F (backlit alphanumeric LCD display of 16 characters customisable in 5 languages, 4-membrane keypad, three types of temperature alarms and recording of 12 events), the ECT-F PLUS (adds backup battery for power failure alarm up to 48 h, minimum/maximum temperature recording and clean contact for remote alarm) or the ECT-F TOUCH (7\” touch screen, real-time graph, SD card, USB port, SIM port, integrated Web Server LAN RJ45, MODBUS TCP/IP, anti-freeze and anti-overheating protection, and dry contact for remote alarm).
3. Technical Specifications
Structure and refrigeration
| Parameter | Specification |
|---|---|
| Manufacturer / Series | Fiocchetti, LABOR 2T series (dual temperature) |
| Temperature range | +2/+15 °C | -10/-25 °C |
| Nominal capacity | 250+250 lt (8.82+8.82 cu ft) |
| Net capacity | 249+230 lt (8.80 + 8.13 cu ft) |
| Total capacity | 486 lt (17.16 cu ft) |
| Internal dimensions | 60 x 58.8 x 70 / 60 x 58.8 x 74 cm |
| External dimensions (HxDxW) | 72 x 74.5 x 208 cm |
| Insulation type | High-density injected polyurethane foam (43 kg/m³), CFC-free and with ecological water injection |
| Insulation thickness | 75 mm rear / 60 mm sides |
| Structure | Steel with white antibacterial plasticised PVC; rounded corners and chamber with a base |
| Mobility | 4 unidirectional wheels + 2 front stability feet |
| Internal lighting | Full LED across the full height of the chamber, with intensity adjustment |
| Cooling type | Professional ventilated |
| Defrosting type | Adaptive automatic with condensate evaporation |
| Energy saving | Night & Day function |
Technical data of the refrigerator
| Parameter | Value |
|---|---|
| Refrigerant gas type | R290 |
| Consumption | 4.5 kWh/24h |
| Absorbed power | kW 0.17+0.32 / Amp 1+2.3 |
| Starting absorption | Amp 3+5 |
| Noise level | <50 dBA |
| Heat output EN 12900 | W 187 |
| Max. no. of shelves | 3+3 (cm 56×55) |
| Max. no. of drawers | 5+3; with dividers cm 15x50x7.5 (3 spaces); without dividers cm 49x50x7.5 |
Electronic controller
| Parameter | Specification |
|---|---|
| Available controllers | ECT-F / ECT-F PLUS / ECT-F TOUCH |
| Display | Backlit alphanumeric LCD display of 16 characters, customisable in 5 languages; display configurable in four reading modes (ECT-F and PLUS versions) |
| Accuracy | ±0.3 °C (resolution of 0.1 °C) |
| Keyboard | 4 membrane keys with password protection (on-off and setpoint) |
| Alarms | Temperature alarms and recording of 12 events; power failure alarm options (48 h backup battery), min/max recording and clean contact for remote alarm (ECT-F PLUS) |
| ECT-F TOUCH | 7\” touch screen, real-time graph, SD card, USB port, SIM port (optional GSM module), integrated Web Server (LAN RJ45) and MODBUS TCP/IP; optional accessories: electronic lock, DMLP TOUCH module, GSM and Wi-Fi modules, integration with local and cloud monitoring systems |
Available references
| Model | Fiocchetti code | Controller | Temperature range | Capacity | External dimensions (HxDxW) |
|---|---|---|---|---|---|
| LABOR 2T 500 ECT-F | LAD0501 | ECT-F | +2/+15°C | -10/-25°C | 486 lt (17.16 cu ft) | 72 x 74.5 x 208 cm |
| LABOR 2T 500 ECT-F PLUS | LAD0503 | ECT-F PLUS | +2/+15°C | -10/-25°C | 486 lt (17.16 cu ft) | 72 x 74.5 x 208 cm |
| LABOR 2T 500 TOUCH | LAD0502 | ECT-F TOUCH | +2/+15°C | -10/-25°C | 486 lt (17.16 cu ft) | 72 x 74.5 x 208 cm |
4. Equivalences and Cross-References
This datasheet covers the three controller variants of the same Fiocchetti unit (LAD0501 ECT-F, LAD0503 ECT-F PLUS and LAD0502 TOUCH), which share the cabinet, external dimensions, 486-litre capacity and temperature range of -10/-25 °C; the choice depends solely on the level of traceability and monitoring required by the facility. The variants are interchangeable with each other while maintaining identical measurements, capacity and refrigeration performance.
Within the same manufacturer and the same LABOR 2T platform, in different capacities, the following family models are available (same dual-temperature performance):
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Bow ties | LABOR 2T 500 ECT-F PLUS | LAD0503 | Exact reference equivalence (same manufacturer) | Identical dimensions and capacity; adds 48 h backup battery, min/max recording and contact for remote alarm |
| Bow ties | LABOR 2T 500 TOUCH | LAD0502 | Exact reference equivalence (same manufacturer) | Identical dimensions and capacity; incorporates 7″ touch screen, SD/USB recording, web server and MODBUS |
| Bow ties | LABOR 2T 400 | LAD0401 / LAD0403 / LAD0402 | Comparable by category (not interchangeable 1:1) | Same family, lower capacity (358 L) and same range -10/-25 °C; dimensions 60 x 64.5 x 202 cm |
| Bow ties | LABOR 2T 280 | LAD0281 / LAD0283 / LAD0282 | Comparable by category (not interchangeable 1:1) | Same family, lower capacity (306 L) and range -10/-20 °C; dimensions 52 x 66.5 x 166.5 cm |
| Bow ties | LABOR 2T 700 | LAD0701 / LAD0703 / LAD0702 | Comparable by category (not interchangeable 1:1) | Same family, higher capacity (593 L) and extended range down to -30 °C |
There is no manufacturer-validated equivalence table cross-referencing this reference with other manufacturers; consult the Cahnos technical department before using it in a tender. By category, the homologous families of combined fridge-freezer units for pharmacy and laboratory are those from Liebherr (MediLine range and pharmacy combinations), B Medical Systems (vaccine refrigerators/freezers with monitoring), Haier Biomedical and PHC Europe (dual-temperature combinations for pharmaceutical storage). Before any substitution between brands, the following must be verified one by one: actual temperature range, net capacity, dimensions, refrigerant gas, climate class, alarm/recording system and applicable vaccine regulations.
5. Selection tips and variants of interest
Choose the controller according to your traceability needs: the ECT-F covers basic management with three types of temperature alarm and recording of 12 events; the ECT-F PLUS adds a 48 h backup battery for power cuts, minimum/maximum recording and a clean contact for remote alarm, essential in vaccine cold chains without guaranteed power supply; the TOUCH provides continuous recording, real-time graphs and LAN/MODBUS connectivity for integration into local or cloud monitoring systems.
Check the installation space: the unit occupies 72 x 74.5 x 208 cm; confirm door clearances and side and rear ventilation distances for optimal performance.
Capacity: with 250+250 nominal litres and 486 total useful litres, it is the high-volume option in the dual-temperature series. For smaller volumes, consider the LABOR 2T 400 (358 L) or the LABOR 2T 280 (306 L); for greater capacity and deep freezing down to -30 °C, the LABOR 2T 700 (593 L), all from the same Fiocchetti family.
Pharmacy use: if the destination is vaccine storage, the ECT-F PLUS or TOUCH version is recommended for temperature recording and remote alarm, and thermal validation and equipment qualification should be carried out according to the facility’s protocol. Sale is made on quotation: Fiocchetti configures each unit to order.