Description
1. Commercial Introduction
The combined blood and plasma bank Fiocchetti PLASMA-VISION 2T 500 TOUCH (ref. Cahnos FIO-DMD0502, factory code DMD0502) is the dual-temperature solution in a single vertical unit with two glass doors: it stores blood at positive temperature (+2/+6 °C) and frozen plasma at -10/-20 °C in two completely independent compartments, each with its own refrigeration unit. With a capacity of 486 litres, it is certified as a class IIa medical device in accordance with Directive 93/42/EEC and its amendment 2007/47/EC, is registered in the Medical Devices Register of the Italian Ministry of Health and complies with the RoHS Directive 2011/65/EU.
The two glass doors allow visual supervision of the contents without opening the unit, minimising cold losses, while the customisable interior (shelves and drawers) optimises the storage of blood bags, fresh frozen plasma and blood products. It is the reference choice for blood banks, transfusion services and small and large volume laboratories that require rigorous thermal traceability. It is supplied on order and formal quotation; contact our technical-commercial team to configure the interior.
2. Technical explanation of the equipment
The PLASMA-VISION 2T series integrates two independent refrigeration circuits in a single vertical cabinet, allowing simultaneous storage of refrigerated blood (usually +4 °C) and frozen plasma (-20 °C) without the risk of cross-contamination of temperatures. The cooling is professional ventilated: cold air is distributed homogeneously throughout the chamber, with adaptive automatic defrosting and evaporation of condensate, which eliminates manual maintenance and minimises thermal fluctuations.
The high-density injected polyurethane foam insulation (43 kg/m³), CFC-free and with ecological water injection, complemented by the Night & Day energy-saving function, ensures a contained consumption of 5.5 kWh/24h. The monobloc structure is made of steel with white antibacterial plasticised PVC, interior and exterior, with rounded corners and a chamber with base; it includes 4 unidirectional wheels and two front feet for maximum stability, as well as full LED lighting with intensity adjustment along the entire height of the chamber.
The microprocessor controller ECT-F TOUCH with 7″ touch screen simultaneously displays a real-time graph, the current temperature, the programmed setpoint and the alarm limits (both editable), the energy consumption and the battery status, with a resolution of 0.1 °C and an accuracy of ±0.3 °C. It includes as standard the independent recording module DMLP TOUCH with backup battery, which maintains the temperature and alarm log even during a power outage, the product temperature simulation probe, the electronic lock with generic or individual password per user, dry contacts for remote alarm and RJ45 port with integrated web server and MODBUS TCP/IP protocol. The acoustic and visual alarms, which can be silenced, are automatically recorded with date, time, type, duration and maximum temperature reached. It is always possible to integrate the optional GSM and Wi-Fi modules and local or cloud monitoring systems.
3. Technical Specifications
3.1. Structure and refrigeration
| Configuration | Combined refrigerator + freezer, 2 independent compartments with 2 refrigeration units and 2 glass doors |
| Temperature range | Compartment A (blood): +2/+6 °C | Compartment B (plasma): -10/-20 °C |
| Nominal capacity | 250+250 lt (8.82+8.82 cu ft) |
| Net capacity | 249+230 lt (8.80 + 8.13 cu ft) |
| Internal dimensions | 60 x 58.8 x 70 / 60 x 58.8 x 74 cm |
| External dimensions (HxDxW) | 72 x 76 x 208 cm |
| Electronic controller | ECT-F TOUCH (7″ touchscreen) |
| Insulation type | High-density injected polyurethane foam (43 kg/m³), CFC-free and with ecological water injection |
| Insulation thickness | 75 mm rear / 60 mm sides |
| Structure | Steel with white antibacterial plasticised PVC (interior and exterior); rounded corners and chamber with base. 4 unidirectional wheels included and 2 front feet for maximum stability |
| Internal lighting | Full LED across the full height of the chamber, with intensity adjustment |
| Cooling type | Professional ventilated |
| Defrosting type | Adaptive automatic with condensate evaporation |
| Energy saving | Night & Day function |
3.2. Electronic controller ECT-F TOUCH and safety
| Display | 7″ touchscreen with real-time graph; resolution 0.1 °C and accuracy ±0.3 °C |
| Registration | Temperatures and alarms with date, time, type, duration and maximum temperature; history on SD card |
| Ports | SD card (data history), USB (download and system update) and SIM card (for optional GSM module) |
| Connectivity | Integrated web server for LAN (RJ45) and MODBUS TCP/IP; dry contacts for remote alarm |
| DMLP TOUCH module | Independent recording with backup battery (operates during power outage); product temperature simulation probe |
| Safety | Anti-freezing and anti-overheating devices; electronic lock with generic or per-user password; silenceable acoustic and visual alarms |
| Optional accessories | GSM and Wi-Fi modules; local and cloud monitoring systems |
3.3. Technical data of the refrigerator
| Refrigerant gas type | R290 |
| Consumption | 5.5 kWh/24h |
| Absorbed power | kW 0.17+0.32 / Amp 1+2.3 |
| Starting absorption | Amp 3+5 |
| Noise level | <50 dBA |
| Heat output EN 12900 | W 229 |
| Number of shelves included | 4 (2+2) |
| Max. no. of shelves | 3+3 |
| Shelf dimensions | cm 56×55 |
| Max. no. of drawers | 5+3 |
| Internal dimension of drawers with dividers (LxDxH) x number of spaces | cm 15x50x7.5 (3) |
| Internal dimension of drawers without dividers (LxWxH) | cm 49x50x7.5 |
| Classification | Medical device class IIa (Directive 93/42/CEE and amendment 2007/47/CEE); RoHS 2011/65/CE |
3.4. Available references
| Model | Fiocchetti code | Controller | Temperature range | Capacity | External dimensions (HxDxW) |
|---|---|---|---|---|---|
| PLASMA-VISION 2T 500 TOUCH | DMD0502 | ECT-F TOUCH | +2/+6°C | -10/-20°C | 486 lt (17.16 cu ft) | 72 x 76 x 208 |
| PLASMA-VISION 2T 400 TOUCH | DMD0402 | ECT-F TOUCH | +2/+6°C | -10/-20°C | 358 L (12.64 cu ft) | 60 x 66 x 202 |
| PLASMA-VISION 2T 700 TOUCH | DMD0702 | ECT-F TOUCH | +2/+6°C | -10/-20°C | 593 L (20.94 cu ft) | 72 x 85.5 x 203 |
4. Equivalences and Cross-References
The factory code of this unit is DMD0502 (model PLASMA-VISION 2T 500 TOUCH), verified in the official technical data sheet of the manufacturer Fiocchetti Scientific S.r.l. and on its corporate website; the corresponding Cahnos SKU is FIO-DMD0502. The variants of the same series and from the same manufacturer with glass doors are DMD0402 (2T 400, 358 litres) and DMD0702 (2T 700, 593 litres), identical in controller and certification and differing only in capacity and dimensions. As variants from the same manufacturer with solid door, the PLASMA-LABOR 2T series offers DML0502 and DML0402, and the PLASMA-SUPERARTIC 2T series the DMT0702 (-20/-40 °C).
There is no equivalence table validated by the manufacturer relating this model to specific codes from other manufacturers of combined refrigerator-freezer cabinets for blood banks with glass doors; consult the technical department before using in tenders. The comparable brands and families in the sector for this category (dual-temperature cabinets for blood + plasma, positive range +2/+6 °C and frozen -20/-25 °C, with continuous recording and alarms, for blood bank and transfusion use) include Angelantoni Life Science, Kirsch, Liebherr (Medline range), Gram and Labcold. They are comparable at category level, not interchangeable 1:1: each manufacturer has different chamber geometry, controller, internal equipment, door type, consumption, refrigerant gas and certifications. Before any replacement, compare field by field the thermal range of both compartments, net capacity, dimensions, chamber material, controller type and regulatory classification, validating with the technical department of Cahnos.
5. Selection tips and variants of interest
Installation space: provide access for a unit of 72 x 76 x 208 cm (W x D x H) and ensure adequate ventilation (75 mm insulation at the rear and 60 mm on the sides). Check doorways, corridors and delivery platform before placing the order; the unit includes 4 unidirectional wheels to facilitate its movement.
Traceability and regulations: if your specification requires independent continuous recording and alerts in the event of power cuts, this model includes it as standard with the DMLP TOUCH module with backup battery, product temperature simulation probe, dry contacts and RJ45. For integration into the hospital network, request the GSM/Wi-Fi modules and cloud monitoring.
Internal configuration: the unit supports up to 3+3 shelves (includes 4 as standard, 56×55 cm) and up to 5+3 drawers with or without dividers, allowing you to organise blood bags (red blood cell concentrates, platelets) and fresh frozen plasma according to your service flow. Racks and accessories are quoted separately.
Variants of the same family: if your patient volume is lower, the PLASMA-VISION 2T series offers the 400 model (DMD0402, 358 litres); if you need greater capacity, the 700 (DMD0702, 593 litres), both with the same controller and certification. If you only need to store frozen plasma, see the PLASMA-VISION (DMV0402, DMV0702) or PLASMA-FREEZER TOUCH series; if your centre’s regulations require a solid door or deeper ranges, consider the PLASMA-LABOR 2T series. Sales are made under a formal quotation; contact our technical-commercial team to size the correct solution and receive the regulatory documentation (technical data sheet, CE certificate) for tenders and bids.