Description
1. Introduction
The Fiocchetti blood bank EMOTECA TWIN 1500 TOUCH (code DMW1502) is the high-capacity solution of the EMOTECA TWIN series for the safe storage of whole blood, plasma, blood products and donated breast milk at a constant temperature of +4 °C. Designed and certified as a class IIa medical device, it is the ideal equipment for hospitals, blood banks, services and transfusion centres, nursing homes and blood collection centres with high activity volumes that demand reliability, traceability and compliance with the most restrictive health regulations, both national and international.
This equipment is supplied on a quotation basis: Fiocchetti configures each unit to order according to the centre’s needs.
2. Technical explanation of the equipment
The EMOTECA TWIN series features two independent refrigeration units with alternating function: the dual ECT-F TOUCH controller alternately activates the two compressors in each operating cycle. In the event of failure of one of them, the remaining one is activated with an immediate alarm signal to the operator, maintaining performance at the highest level. Each refrigeration system (A or B) is controlled independently and diagnoses its own faults (sensors, condenser overheating, low evaporator temperature, etc.).
It incorporates as standard the microprocessor controller with 7\” touch screen (resolution of 0.1 °C and accuracy of ±0.3 °C) with continuous recording of temperatures and alarms, real-time graph, editable setpoint and alarm limits, energy consumption and battery status. It also includes the DMLP TOUCH module with backup battery for independent recording of data and alarms even in the event of a power failure, the product temperature simulation probe, the electronic lock for access control, dry contacts for remote alarm and RJ45 port with integrated web server (LAN and MODBUS TCP/IP). It is possible to integrate optional GSM and Wi-Fi modules, as well as local and cloud monitoring systems.
Professional ventilated refrigeration ensures uniform cold distribution with adaptive automatic defrosting with condensate collection and Night & Day energy saving function. Its 14 drawers with separators for blood bags facilitate the organisation, access and traceability of the stored product.
Fiocchetti blood banks are medical devices that comply with Directive 93/42/EEC and its amendment 2007/47/EEC (class IIa), are registered in the Medical Devices Register of the Italian Ministry of Health and comply with standards DIN 13277 and 2011/65/EC (RoHS).
3. Technical Specifications
Available references
| Model | Fiocchetti code | Controller | Temperature range | Capacity | External dimensions (HxDxW) |
|---|---|---|---|---|---|
| EMOTECA TWIN 1500 TOUCH | DMW1502 | ECT-F TOUCH | +4°C | 1355 lt (47.85 cu ft) | 144 x 83 x 204 cm |
Structure and refrigeration
| Characteristic | Specification |
|---|---|
| Internal dimensions | 130 x 67 x 150 cm |
| Blood bag capacity (450 ml) | No. 672 |
| Nominal capacity | 1500 lt (52.97 cu ft) |
| Net capacity | 1355 lt (48.87 cu ft) |
| Insulation type | High-density injected polyurethane foam in the walls (43 kg/m³), CFC-free and with ecological water injection |
| Insulation thickness | 70 mm |
| Structure | Steel with white antibacterial plasticised PVC (interior and exterior) or option of internal structure in 18/10 Aisi 304 steel; rounded corners and chamber with base |
| Stability | 4 height-adjustable feet to ensure maximum stability |
| Refrigerating units | No. 2 with alternating function (systems A and B with independent control) |
| Internal lighting | Full LED along the entire height of the internal chamber with intensity adjustment |
| Cooling type | Professional ventilated |
| Defrosting type | Adaptive automatic with condensate collection |
| Energy saving | Night & Day function |
Electronic controller with 7″ touch screen
| Characteristic | Specification |
|---|---|
| Controller | ECT-F TOUCH (microprocessor with 7″ touch screen) |
| Resolution / accuracy | 0.1 °C / ±0.3 °C |
| Ports (window with 3 ports) | SD card (data history), USB (system download and update), SIM (for optional GSM module) |
| Connectivity | Integrated web server for LAN network connection (RJ45) and MODBUS TCP/IP |
| Safety | Anti-freezing and anti-overheating safety device; dry contacts for remote alarm |
| Standard equipment | Electronic lock, DMLP TOUCH module with backup battery, product temperature simulation probe and terminal box for dry contacts and RJ45 port |
| Alarms | Acoustic and visual, can be silenced, for all abnormal conditions, with automatic recording |
Technical data of the refrigerator
| Characteristic | Specification |
|---|---|
| Refrigerant gas type | R290 |
| Consumption | 2.5 kWh/24h |
| Absorbed power | kW 0.4 / Amp 1.8 |
| Starting absorption | Amp 6 |
| Noise level | 55 dBA |
| Heat output EN 12900 | W 125 |
| No. of drawers included | 14 |
| Maximum number of drawers | 14 |
| Internal dimension of drawers with dividers (LxPxH) (x number of spaces) | cm 15 x 60 x 7.5 (3) |
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer Fiocchetti against other brands; it is recommended to consult with the technical department of Cahnos before its use in tenders. The references of other manufacturers indicated below are comparable by category (blood bank refrigerators at +4 °C), not interchangeable 1:1, and require verification of specifications (capacity, dimensions, controller and regulations) before any substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| B Medical Systems | Blood bank refrigerator B401 | B401 | Comparable by category (not interchangeable 1:1) | Single-chamber refrigerator, gross volume 478 L / storage 390 L, 270 bags of 450 ml, +4 °C, R600a gas, compliant with AABB and EU MDR class IIa. It differs in capacity, refrigerant and in not having a dual refrigeration unit. |
| Helmer Scientific | i.Series Blood Bank Refrigerator (double door) | iBR245-GX / iBR256-GX | Comparable by category (not interchangeable 1:1) | Double-door refrigerators for blood at +4 °C with i.C3 touch screen monitor, AABB certified. They differ in capacity and refrigeration technology. |
| Bow ties | EMOTECA 1500 TOUCH (one chamber, one refrigeration unit) | DME1502 | Variant of the same range | Same chamber capacity (1355 lt net, 672 bags of 450 ml) and external dimensions 144 x 83 x 207 cm, with a single refrigeration unit. The EMOTECA TWIN 1500 (DMW1502) adds cold redundancy with two independent refrigeration units with alternating function. |
5. Selection tips and variants of interest
Before choosing, assess the number of bags to be stored (this model holds 672 blood bags of 450 ml), the available floor space (144 x 83 x 204 cm), the noise level and consumption (55 dBA / 2.5 kWh per 24 h) and the need for remote monitoring and access control, elements that this unit includes as standard with the touch controller, the DMLP TOUCH module, the electronic lock and the RJ45 port. The twin refrigeration unit with alternating function makes it especially recommended for facilities where cold continuity is critical, as it guarantees preservation even if one of the two systems fails.
Within the EMOTECA TWIN series itself, Fiocchetti offers the following variants of the same twin refrigeration unit architecture: EMOTECA TWIN 250 TOUCH (DMW0252, 150 bags), EMOTECA TWIN 400 TOUCH (DMW0402, 180 bags) and EMOTECA TWIN 700 TOUCH (DMW0702, 366 bags). If cold redundancy is not a priority, the single-chamber EMOTECA series offers the EMOTECA 1500 TOUCH (DME1502), with identical capacity. To separate products in independent chambers, the dual-chamber, dual-door EMOTECA 2T range (DMB0282, DMB0402, DMB0502) is the recommended alternative. All incorporate the ECT-F TOUCH touch controller; always check compatibility with your local or cloud monitoring system via the RJ45 port. The unit is custom-configured and sold on quotation.