Description
1. Echocardiography couch with hydraulic scissor lift: versatility and accessibility in the cardiology clinic
The AGA echocardiography couch with scissor mechanism (SKU AGA-H-EKA-Y-920) is the ideal solution for cardiology clinics, non-invasive diagnostic units and echocardiography rooms that require equipment with an extraordinary height range (500–920 mm) without depending on the mains power supply. Thanks to its hydraulic operation via integrated foot pump, the professional can adjust the work surface with complete freedom, adapting it to each patient and each procedure.
Manufactured by AGA Sanitätsartikel GmbH (Löhne, Germany), this couch can descend to the height of a wheelchair: at its lowest position, the upper edge of the upholstery is approximately 500 mm from the floor, making it especially suitable for frail, elderly or patients with reduced mobility. It is supplied in two frame finishes (lacquered or chrome-plated) and two board widths (650 and 800 mm).
2. Technical explanation: how the hydraulic scissor lift works
Echocardiographic examination requires the patient to remain in lateral decubitus or supine position while the transducer rests on the acoustic window of the chest. This couch incorporates in the backrest section a specific opening of 325 x 260 mm for the transducer, which allows the specialist to introduce the catheter from the lower area of the patient, improving the working angle and image quality without forcing postures. The sliding upholstered insert, included as standard, closes the opening when the examination is not being performed.
The hydraulic system, adjustable independently of the electrical supply, is operated via the integrated foot pump: press the pedal to raise the upholstered frame and lift the pedal with your foot to lower it. The total travel of 420 mm is achieved thanks to the scissor mechanism, which allows the couch to be raised or lowered even with patients up to 200 kg without effort. The stability and robustness of the assembly are achieved through reinforcement gussets at the corners of the frame. The backrest is adjustable up to +30° in 13 locking positions.
3. Technical Specifications
The reference characteristics of the AGA hydraulic scissor echocardiography couch are detailed below:
Manufacturer’s specifications
| Characteristic | Value |
|---|---|
| Length | 1900 mm |
| Backrest / main panel | 800 / 1100 mm |
| Height adjustment | 500 – 920 mm (hydraulic) |
| Upholstery sections | 3 sections |
| Upholstery thickness | 64 mm |
| Backrest adjustment | +30° (rack, 13 positions) |
| Echocardiography opening | 325 x 260 mm (L x W) |
| Maximum load | 200 kg |
Note: the term “frame” in this range refers only to the upholstered board frame. The frame diagonals and the base frame are supplied only in lacquered finish.
Available references
| Reference AGA | Frame | Width |
|---|---|---|
| H-EKA 1065/Y 920 | Lacquered | 650 mm |
| H-EKA 2065/Y 920 | Chrome-plated | 650 mm |
| H-EKA 1080/Y 920 | Lacquered | 800 mm |
| H-EKA 2080/Y 920 | Chrome-plated | 800 mm |
The standard version includes: removable (sliding) upholstered insert to close the echocardiography opening and floor protectors (push caps) on the four adjustable legs.
Accessories and available options
| Reference | Item | Detail | Type |
|---|---|---|---|
| FPH-10 | Foot lever | With transmission shaft and connection piece. Allows the hydraulic height adjustment to be operated from both sides. | Accessory |
| LR-75 | Wheel set | Wheels Ø 75 mm — four swivel castors, two fully lockable. Retrofit not possible. | Factory option |
| LR-125 | Wheel set | Wheels Ø 125 mm — four swivel castors, two fully lockable. Retrofit not possible. | Factory option |
| LR/Z-125 | Central locking castor system | Double swivel castors Ø 125 mm — mobility via centralised locking system: the four castors connected to each other by rods, pedals arranged diagonally at head and foot ends, with colour marking (green = ready to move, red = locked). Retrofit not possible. | Factory option |
| P-2065/A | Paper roll holder | For 650 mm width — chrome-plated, consisting of two fixing kits, two brackets, two clamps and a roll holder bar (length 615 / 795 mm, Ø 20 x 1 mm), for mounting on the upholstery frame. | Accessory |
| P-2080/A | Paper roll holder | For 800 mm width — chrome-plated, consisting of two fixing kits, two brackets, two clamps and a roll holder bar (length 615 / 795 mm, Ø 20 x 1 mm), for mounting on the upholstery frame. | Accessory |
The hydraulic scissor echocardiography couches can be equipped, for example, with perimeter edge/impact protection or with synthetic leather upholstery in another colour on request. Each configuration is quoted individually (frame, upholstery colour, height and accessories).
4. Equivalences and Cross-References
The four AGA references in this family (H-EKA 1065/Y 920, H-EKA 2065/Y 920, H-EKA 1080/Y 920 and H-EKA 2080/Y 920) are variants from the same manufacturer (AGA Sanitätsartikel, Germany) that differ only in the frame finish (lacquered or chrome-plated) and the tabletop width (650 or 800 mm); any reference in the series can be considered a direct equivalent within the brand itself if the required width matches. The versions with manual crank lift (H-EKA …/H), standard hydraulic (H-EKA …/Y) and electric (H-EKA …/E) perform the same clinical function with a different drive system.
At category level, specific echocardiography solutions exist from other manufacturers, expressed as a functional comparison, not interchangeable 1:1:
| Manufacturer / Brand | Family / Model | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|
| MPI – Medical Positioning (USA) | EchoBed® X – Echo Table | Comparable by category (not interchangeable 1:1) | Echocardiography table with transducer access and design oriented to specialist ergonomics. Verify height adjustment (electric vs hydraulic), opening dimensions, maximum load and material before replacement. |
| Mirion (USA) | Echo Pro™ Echocardiography Table | Comparable by category (not interchangeable 1:1) | Open chassis with folding cardiac examination cushion allowing transducer access from both sides. Verify height range, maximum load and tabletop dimensions against the AGA H-EKA/Y 920. |
| Oakworks Medical (USA) | Ultrasound/echocardiography table series 65258-Txx | Comparable by category (not interchangeable 1:1) | Ultrasound table with cut-out for transducer and positioning accessories. Confirm specific reference, height travel and maximum load before use in tendering. |
There is no equivalence table validated by the manufacturer that cross-references the AGA H-EKA/Y 920 with third-party codes on a 1:1 basis; for any replacement in tenders or competitions, it is recommended to verify field by field (tabletop length and width, height range, opening dimensions, maximum load and included accessories) and consult our technical department.
5. Selection tips and variants of interest
- Tabletop width: the 650 mm version (H-EKA 1065/Y 920 or H-EKA 2065/Y 920) is ideal for practices with limited space; the 800 mm version (H-EKA 1080/Y 920 or H-EKA 2080/Y 920) offers a larger support surface, recommended for larger patients or prolonged examinations.
- Frame finish: chrome-plated (20xx series) offers greater resistance to impacts and external agents; lacquered (10xx series) maintains the same structural stability.
- Maximum travel: if you need to lower the stretcher to wheelchair height (approximately 500 mm) or adapt to very low surfaces, this hydraulic scissor variant is the reference option; the electric scissor version (H-EKA …/E 965, travel 535–965 mm) is the motorised alternative in the same family.
- Dual-side actuation: to operate the hydraulics from both sides, order the additional foot lever FPH-10.
- Mobility: the stretcher is supplied with fixed levelling legs; if you need to move it around the practice, order the wheel set LR-75 or LR-125, or the centralised brake system LR/Z-125 (factory option, not retrofittable).
- Additional equipment: paper roll holder P-2065/A (650 mm) or P-2080/A (800 mm) for mounting on the upholstery frame.
For special configurations, upholstery colours, tender specifications or volume quotations, our technical-commercial team is at your disposal.



















Reviews
There are no reviews yet.