Description
1. Commercial Introduction
Keep your endoscopic linear surgical stapler always operational with this articulated spare reload of 60 mm and white staple of 2.5 mm. It is the replacement that your surgical service needs to complete the WZULS series, with the guarantee of a new, sterile and single-use product, with traceable reference for warehouse control and management of operating theatre consumables. A reliable and precise solution for minimally invasive procedures, with a secure, homogeneous closure and effective haemostasis in each intervention.
2. Technical explanation
The endoscopic linear stapler (laparoscopic endocutter) simultaneously places several rows of staples and divides the tissue between them. This articulated reload has triple staggered rows of titanium staples that sew the tissue simultaneously, creating a continuous and uniform suture line; this configuration prevents postoperative bleeding, reduces clinical risk and improves the airtightness of the anastomosis compared with conventional double-row systems. When the tissue is compressed against the anvil, the staples close taking the ‘B’ shape, an indicator of a reliable mechanical suture with good sealing.
The articulated head incorporates a three-level rotation system (15°, 30° and 45°), allowing access to anatomical areas that are difficult to reach and adapting the approach angle without losing firing precision. The white colour identifies the 2.5 mm height configuration, associated with fine and vascular tissue (mesentery, thin wall, fine pulmonary parenchyma). The reload is single-use and is supplied in sterile packaging, eliminating the risk of cross-infection and guaranteeing the sharpness of the mechanism on each firing.
3. Technical Specifications
3.1. Characteristics of this reload (WZULS-P2-60-2.5)
| Characteristic | Specification |
|---|---|
| Reference Cahnos | WZULS-P2-60-2.5 |
| Product type | Articulated replacement load (reload) for endoscopic linear stapler |
| Staple line length | 60 mm |
| Staple height | 2.5 mm (B-shaped closure) |
| Identification colour | White (fine / vascular tissue) |
| Row configuration | Triple staggered row of staples |
| Staple material | Titanium |
| Rotation of the articulated head | 15°, 30° and 45° |
| Compatibility | Endoscopic linear surgical stapler series WZULS (universal handle, shaft diameter 12 mm) |
| Use | Single-use |
| Presentation | Sterile unit, ready for the operating theatre |
| Application | Resection, anastomosis and transection in endoscopic surgery of the gastrointestinal tract and other digestive tracts |
3.2. Family of replacement loads (WZULS-P2 series)
| Reference | Length (mm) | Staple height (mm) | Colour |
|---|---|---|---|
| WZULS-P2-30-2.5 | 30 | 2.5 | White |
| WZULS-P2-45-2.5 | 45 | 2.5 | White |
| WZULS-P2-45-3.5 | 45 | 3.5 | Blue |
| WZULS-P2-45-4.8 | 45 | 4.8 | Green |
| WZULS-P2-60-2.5 (this reference) | 60 | 2.5 | White |
| WZULS-P2-60-3.5 | 60 | 3.5 | Blue |
| WZULS-P2-60-4.8 | 60 | 4.8 | Green |
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer that cross-references the WZULS-P2 series with the references of the major mechanical suture houses; consult the technical department before use in tenders. The following references are offered as a functional category comparison verified against public sources from each manufacturer or authorised distributor, never as direct 1:1 interchangeable items. Before any substitution, validation must be carried out field by field: exact dimensions, material, anchor geometry, number of rows, regulatory classification and mechanical compatibility with the handle.
| Manufacturer / Brand | Family / Model | Indicative reference | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Medtronic (Covidien) | Endo GIA™ Universal Roticulator™ | 030457 (60 mm × 2.5 mm, white) | Comparable by category, not interchangeable 1:1 | White 60 mm articulated reload, titanium staples, 6 staggered rows, articulation up to 45° and 12 mm shaft. Proprietary anchor and anvil system; does not fit the WZULS handle. |
| Ethicon (Johnson & Johnson MedTech) | ECHELON ENDOPATH™ GST (GST technology + B shape) | GST60W (60 mm, white, fine tissue) | Comparable by category, not interchangeable 1:1 | White 60 mm reload for mesentery and fine tissue (open height 2.6 mm), 6 rows with B-shaped closure. Proprietary ECHELON platform with different anchor; not interchangeable 1:1. |
| Generic manufacturers of endoscopic reloads | White 60 mm articulated reload | No unified public reference | Comparable by category, not interchangeable 1:1 | Equivalent specification (60 mm, white, 2.5 mm, articulated) in generic reloads on the market; verify with each supplier before substituting. |
Traceability notice: the code WZULS-P2-60-2.5 is Cahnos’s own reference (WZ manufacturer); it has not been found in independent public sources, so it must be treated as a distribution/factory code and confirmed with the manufacturer before use in technical specifications. The third-party references shown (030457, GST60W) come from public sources of each manufacturer or authorised distributor and are offered solely as comparative guidance.
5. Selection tips and variants of interest
- Staple height by tissue: the white 2.5 mm reload (this reference) is the indicated option for fine and vascular tissue (mesentery, thin wall, fine parenchyma). For medium-wall tissue (stomach, small intestine, colon) select the blue 3.5 mm reload; for thick or oedematous tissue, the green 4.8 mm reload.
- Line length: choose 30 mm (WZULS-P2-30) for short lines or reduced fields, 45 mm (WZULS-P2-45) as the usual balance in digestive surgery and 60 mm (this reload) for wide transections or extensive resections.
- Articulated vs. standard head: the articulated version facilitates access to areas that are difficult to expose; if your protocol prioritises maximum shaft stability, consider the straight reloads from the same family (WZULS-P1 series, e.g. WZULS-P1-60-2.5).
- Verification before firing: confirm that the reload engages with the positioning click of the handle, the correct advance of the retention pin and the audible closure signal. Do not reuse or re-sterilise the unit.
- Compatibility in tenders: as this is an alternative reference to the major houses, verify acceptance of the reference in your internal operating theatre protocol and in public tenders before formalising the order. Consult our technical department for any compatibility queries.








Reviews
There are no reviews yet.