Description
1. Commercial Introduction
Did you know that the noise generated by an MRI machine during sequence acquisition can exceed 100 dB? Protecting the patient’s hearing is not only a matter of comfort, but also of safety and diagnostic quality. The disposable earplugs CAHNOS-IRM30225 from Cahnos effectively reduce the sound pressure reaching the ear during the scan, helping the patient to remain calm and still and avoiding repeat examinations due to involuntary movements. Their presentation in a container of 100 units (50 pairs) makes them the hygienic and economical solution for radiology departments, MRI imaging clinics and hospitals that need continuous replenishment.
2. Technical Explanation
During an MRI scan, the rapid switching on and off of currents in the gradient coils causes mechanical vibrations that generate intense, pulsatile acoustic noise of variable frequency depending on the sequence used. These earplugs act as a passive physical barrier: once inserted into the ear canal, the foam expands and adapts to the morphology of the canal, reducing the sound pressure level reaching the inner ear. Their hollow interior relieves pressure on the ear and promotes comfort during long studies, while their disposable nature guarantees maximum hygiene between patients and avoids any risk of cross-contamination within the scanning room. As they contain no metal or ferromagnetic components, they are completely safe in the magnet environment and do not interfere with image quality.
3. Technical Specifications
The disposable MRI earplugs feature the following certified characteristics:
| Reference / SKU | CAHNOS-IRM30225 |
| Product type | Disposable foam earplug for MRI |
| Noise reduction rating | NRR 29 dB |
| Regulatory standard | ISO 17025 / ANSI S3.19-1974 |
| Diameter | Ø 13.3 mm |
| Interior design | Hollow, for a comfortable and stable fit |
| Material | High-performance disposable foam |
| Biocompatibility | Tested and certified for medical use |
| Presentation | Container of 100 units (50 pairs) |
| Type of use | Disposable, single patient |
| Application | Hearing protection for patients and staff in the MRI room (RM/IRM/RMN) |
To achieve the maximum level of attenuation in particularly noisy sequences, it is recommended to combine these earplugs with compatible hearing protection earmuffs.
4. Equivalences and Cross-References
These earplugs are part of Cahnos’s noise reduction range for MRI. Within the catalogue, the equivalent and complementary presentations are as follows:
| Reference | Product | Related items |
| R-MN-16 | Disposable anti-noise earplugs for MRI, box of 250 units. | Equivalent in larger volume format |
| R-MN-17 | Disposable anti-noise earplugs in dispenser of 500 units. | Equivalent for dispenser replenishment |
| CAHNOS-IRM3033 | Adjustable low-pressure earmuffs with attenuation up to 29 dB (ANSI) | Complementary for maximum attenuation |
| CAHIRM066 | Protective headphones with -27 dB noise reduction | Functional alternative |
| CAHNOS-IRM3002 | Radiotransparent hearing protection | Alternative with materials inert to the scanner |
| CAHNOS-IRM3013 | Earmuffs with attenuation up to 36 dB | Variant with maximum attenuation |
On the market, this type of disposable foam earplug with NRR 29 dB is comparable in performance to classic hypoallergenic polyurethane foam models such as 3M 1100/1110, as well as to polymer foam earplugs for MRI marketed by the main imaging accessory manufacturers, with the advantage of its hollow interior and certified biocompatibility for clinical use.
5. Selection tips and variants of interest
For particularly noisy sequences or very sensitive patients, combine these earplugs with hearing protection earmuffs (Ref. CAHNOS-IRM3033 or CAHNOS-IRM3013) and achieve attenuation values of up to 36 dB.
If your department requires frequent high-volume replenishment, consider the presentations in a box of 250 units (R-MN-16) or in a dispenser of 500 units (R-MN-17).
For patients scanned with a head coil, refer to the specific protection CAHIRM3012 (24 dB, according to CE regulation EN 61000).
For paediatric or infant patients (0-18 months), the Em’s 4 Bubs earmuffs are available (Ref. CAHNOS-IRM3320).
Always verify the compatibility of the accessory with your MRI equipment and your centre’s safety protocols. Should you have any questions, our technical-commercial department is at your disposal.