We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Disposable Wound Retractor Ring Size M·L 150/160-150/220 | Incision Protector for Endoscopic Surgery and Assisted Laparoscopy (Ref. WZIPS-AML-150-220)

30,00 €

Disposable wound retractor ring, combined size M·L (150/160-150/220), ready for use in endoscopic surgery, assisted laparoscopy and medium-to-large incisions. Opens the incision 360° atraumatically, reduces bleeding and protects the wound edge, minimising the risk of surgical site infection (SSI) and maintaining wound bed moisture. 150 mm channel or tunnel with a length of 220 mm, inner ring of 160 mm and outer ring of 150 mm. Available in the IPS-1 polymer series (model A, adjustable height) and the IPS-B silicone series (model B, fixed height). Sterile single-use unit, B2B price per unit with immediate availability.

International shipping. Import duties and taxes are payable by the recipient.

Reference
WZIPS-AML-150-220

You will also find it in

Description

1. Incision retractor ring, ready for the operating theatre

The Disposable Wound Retractor Ring Size M·L (150/160-150/220), reference WZIPS-AML-150-220, is a single-use incision protector-retractor designed for endoscopic surgery, assisted laparoscopy and small or medium-large incision procedures. It advantageously replaces metal retractors: it distributes tension evenly around the entire wound contour, widens the field of view without aggressive traction and protects the tissue throughout the procedure.

It is a solution commonly used in abdominal surgery, digestive surgery, general surgery, obstetrics and gynaecology, with particular indication in the prevention of surgical site infection (SSI) and secondary endometriosis after caesarean section. Immediate availability and B2B price per unit for hospitals, clinics and purchasing centres.

2. What it is and how it works

The device consists of three functional elements: the outer ring, which remains outside the incision and acts as a stop on the skin; the insertion ring (green), which is introduced into the cavity; and the channel or tunnel, which crosses the abdominal wall, lines the edges of the incision and connects both rings. Once placed, the insertion ring expands inside and the outer ring folds outward, opening the incision 360° with uniform tension and without damaging the tissues.

  • Opens the incision and expands the surgical field without the need for continuous manual traction.
  • Maintains moisture and temperature in the wound bed, promoting healing.
  • Reduces bleeding from the incised edge (containment effect) and prevents exogenous contamination of the wound.
  • Protects the tissue against accidental burns from electrodes and electric scalpel, and against tumour seeding or implantation in the incision.
  • Allows the introduction of curved instruments and the extraction of pieces through the channel.

3. Technical Specifications

This unit corresponds to the combined size M·L of the family, with factory dimensional code 150/160-150/220 (tunnel 150 mm / inner ring 160 mm / outer ring 150 mm / length 220 mm) and dimensional tolerance of ±8.0 mm.

Parameter Value
Reference (SKU) WZIPS-AML-150-220
Factory dimensional code 150/160-150/220
Size M·L (combined, sizes M and L)
Inner ring diameter (D1) 160 mm
Tunnel / channel diameter (D2) 150 mm
Outer ring diameter (D3) 150 mm
Tunnel length 220 mm
Dimensional tolerance ± 8.0 mm
Models / materials Model A: IPS-1 series (polymers); Model B: IPS-B series (silicone)
Use Single-use, disposable
Presentation Unit
Application Endoscopic surgery, assisted laparoscopy, small incision and medium-large access

Materials of the available series

Series / Model Material Configuration
IPS-1 (Model A) Medical-grade polymers Variable tunnel length: adapts to different abdominal wall thicknesses
IPS-B (Model B) Medical-grade silicone Fixed length: stable geometry for defined incisions

Size family and series references (factory codes)

Series Dimensional code Inner ring (mm) Tunnel (mm) Outer ring (mm) Length (mm)
WZIPS-A 50/50-50/220 50 50 50 220
WZIPS-A 60/70-60/220 70 60 60 220
WZIPS-A 60/70-60/150 70 60 60 150
WZIPS-A 80/90-80/150 90 80 80 150
WZIPS-A 120/130-120/220 130 120 120 220
WZIPS-A (this product) 150/160-150/220 160 150 150 220
WZIPS-A 180/190-180/220 190 180 180 220
WZIPS-A 220/230-220/250 230 220 220 250
WZIPS-A 250/260-250/100 260 250 250 100
WZIPS-B 40/30-15/20 40 30 15 20
WZIPS-B 50/40-25/25 50 40 25 25
WZIPS-B 70/70-35/25 70 70 35 25
WZIPS-B 70/60-45/25 60 70 45 25
WZIPS-B 150/70-60/5 70 150 60 5

4. Equivalences and Cross-References

The dimensional code 150/160-150/220 corresponds to a factory nomenclature shared by several manufacturers of incision protector-retractors. The SKU WZIPS-AML-150-220 is a catalogue-specific code of Cahnos (WZIPS family, IPS-1 polymer series or IPS-B silicone series depending on the model). There is no manufacturer-validated equivalence table cross-referencing these references 1:1; the matches shown below are functional comparisons verified against public sources and sector catalogues, and must be confirmed with the technical department before use in tendering.

Manufacturer / Brand Family / Model Code / Reference Equivalence level Technical differences / Remarks
Cahnos (own reference) WZIPS series, size M·L (IPS-1 / IPS-B) WZIPS-AML-150-220 Own reference Catalogue-specific SKU; dimensions D1 160 / D2 150 / D3 150 / length 220 mm. Available in models A (polymers) and B (silicone).
Applied Medical Alexis O (incision protector-retractor) Alexis series, intermediate sizes (according to the manufacturer’s official tables) Comparable by category (not interchangeable 1:1) Same principle of 360° retraction and surgical site protection; polyurethane sheath, size nomenclature by incision length and own regulatory classification. Verify material, dimensions and registration before replacing.
Grena Ltd. (United Kingdom) RingProtect (incision protector-retractor) Dimensional coding by size (e.g. verified for size S: 0221-060070150) Comparable by category The dimensional coding is shared in the category; confirm the specific reference for size M·L in the manufacturer’s official catalogue before use.
Another manufacturer WQA / WQB series Equivalent dimensional coding by size Comparable by category Polyurethane rings; silicone pin (fixed height, WQB series) or polyurethane pin (variable height, WQA series).
Another manufacturer Incision protector-retractor, CSQA series Equivalent dimensional coding by size Comparable by category Variable length series; medical-grade polymer; check the incision range of the equivalent size.
CITEC Group Disposable incision protector CITEC series by size (e.g. CIT-QKB for small sizes) Comparable by category Silicone series; presentations in multi-unit packaging; verify dimensions of size M·L.
Mindray Disposable incision protector-retractors Fixed and variable height series (without verified public 1:1 reference) Functional category comparison Reference family in laparoscopy; no 1:1 reference has been verified in its public catalogues.

Note: the literal match of the dimensional code between manufacturers does not imply automatic clinical interchangeability: before replacing one reference with another, the material, height (fixed or variable), actual diameters and regulatory classification of each product must be checked. There is no manufacturer-validated equivalence table for this reference; consult the technical department of Cahnos before use in tendering or hospital substitution process.

5. Selection tips and variants of interest

  • Size selection: size M·L (150/160-150/220) is the recommended intermediate option for medium-large incisions in assisted surgery; for smaller incisions, consider sizes S (60/70-60/150) and M (120/130-120/220); for wide access, sizes L (180/190-180/220) and XL (220/230-220/250) from the same family.
  • Model A vs. Model B: model A (IPS-1 series, polymers) offers variable tunnel length and is preferable when the thickness of the abdominal wall requires adjusting the height; model B (IPS-B series, silicone) provides maximum flexibility and stable geometry for defined incisions.
  • Channel compatibility: verify that the tunnel diameter (150 mm) accommodates the curved instruments or the part to be removed in single-incision or assisted procedures.
  • Single-use: do not re-sterilise; respect the expiry date and storage conditions of the sterile packaging.
  • Accessories: combine with disposable trocars and the rest of the laparoscopic equipment in the catalogue to complete the surgical field.

For quotations, tender documents and tenders, contact the technical department at Cahnos for validation of the reference and its equivalents.

Additional information

Reference

WZIPS-AML-150-220

Size

M·L (combined)

Dimensional code

150/160-150/220

Inner ring diameter

160 mm

Tunnel diameter

150 mm

Outer ring diameter

150 mm

Tunnel length

220 mm

Dimensional tolerance

± 8.0 mm

Material

Medical-grade polymers (IPS-1 series, model A) / Medical-grade silicone (IPS-B series, model B)

Configuration

Variable height (model A) / Fixed height (model B)

Use

Single-use (disposable)

Application

Endoscopic surgery, assisted laparoscopy, small incision and medium-large access

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Disposable Wound Retractor Ring Size M·L 150/160-150/220 | Incision Protector for Endoscopic Surgery and Assisted Laparoscopy (Ref. WZIPS-AML-150-220)”

Your email address will not be published. Required fields are marked *