Description
Stable surgical exposure and hands-free for the surgeon
The WZRR-A-D Abdominal Retractor Ring is a disposable, manually operated, self-locking retraction system developed for anorectal, rectal, general and paediatric surgical procedures. Its lightweight, ergonomic design in high-strength technical polymer maintains a stable exposure of the operative field without the need for continuous assistance, reducing fatigue of the surgical team and improving the precision of the procedure.
It is indicated for procedures such as repair of anal and rectovaginal fistula, perineal proctectomy, sphincteroplasty, LAR/coloanal anastomosis, Hirschsprung procedures and total proctocolectomy with anal anastomosis/mucosectomy, as well as for any pelvic or abdominal surgery in which effective and sustained tissue retraction is required.
How the self-locking retractor system works
The WZRR-A-D system consists of three elements: a retractor ring of technical polymer with a stepped opening of 3 mm – 2 mm – 1 mm, mobile screws integrated into the ring and retractor hooks that attach to the tissue. The sequence of use is simple:
- Placement of the ring in the correct position around the incision.
- Traction of the tissue or anatomical structure with the retractor hooks.
- Fixing the hooks to the ring using the mobile screws: the self-locking mechanism prevents them from sliding or coming loose throughout the procedure.
The self-retaining ball stops increase the holding force, while the 10 suture windows allow the tissue to be secured at multiple points, distributing tension evenly and reducing the risk of tissue injury. The result is a wide, stable surgical field, with the surgeon’s hands free to work with total precision and without relying on an assistant to maintain exposure.
Technical specifications
The specifications detailed below correspond to reference WZRR-A-D, verified within the WZRR-A retractor ring family against the manufacturer’s official catalogue and authorised distribution sources.
| Characteristic | Technical data |
|---|---|
| System type | Ring retractor with manual self-locking |
| Composition | Retractor ring + movable screws + retractor hooks |
| Ring material | High-strength technical polymer (polycarbonate, PC); fixing elements in stainless steel 304 |
| Fixation mechanism | Self-locking movable screws |
| Opening design | Stepped 3 mm – 2 mm – 1 mm |
| Suture windows | 10 positions |
| Retention system | Self-retaining ball stops |
| Clinical applications | Anorectal, rectal, general and paediatric surgery |
| Use | Single-use (disposable) |
| Presentation | Unit |
WZRR-A retractor ring family (factory references)
| Reference | Main applications |
|---|---|
| WZRR-A-A | Gynaecology, head and neck |
| WZRR-A-B | ENT |
| WZRR-A-C | Thyroid, breast and plastic surgery |
| WZRR-A-D | Anorectal, rectal, general and paediatric |
| WZRR-A-E | Gynaecology and male urology |
| WZRR-A-F | Urology and thyroid |
| WZRR-A-G | General surgery, head and neck |
| WZRR-A-H | Gynaecology and urological surgery |
Compatible retractor hooks (WZRR-P series)
| Hook type | Size | Reference |
|---|---|---|
| Blunt (blunt tip) | S | WZRR-P1-S-1 |
| Blunt (blunt tip) | L | WZRR-P1-L-1 |
| Sharp | S | WZRR-P2-S-1 |
| Sharp | L | WZRR-P2-L-1 |
| Rake | L | WZRR-P3-L-1 / -3 / -4 |
Equivalences and cross-references
The code WZRR-A-D has been cross-checked against the manufacturer’s catalogue and independent commercial sources. There is no equivalence table validated by the manufacturer for this family; the references indicated below are comparable at category level (unless otherwise stated) and should not be considered 1:1 interchangeable without verifying their specific specifications. Consult our technical department before use in tenders.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| National Surgical Corporation (Australia) | Ascot Retractor System – Type D | MC-WZRR-A-D | Exact reference equivalence | Same factory system; the «MC» prefix is the Australian distributor’s code |
| CooperSurgical (USA) | Lone Star Retractor System – Colorectal Kit | 3707 (ring 3307G of 14.1 x 14.1 cm + hooks 3311-8G) | Comparable at category level, not interchangeable 1:1 | Square grooved ring with elastic stay-type hooks; no adjustment screws; reusable and disposable configurations |
| Chamfond Biotech (China) | Self-Retaining Retractor C11 | C11 (14.4 x 14.4 cm) | Comparable at category level, not interchangeable 1:1 | Indicated for colorectal, general and head and neck surgery; different manufacturer; confirm material and geometry |
| Grena (United Kingdom) | RingProtect™ Disposable Retractor | Adjustable models (consult catalogue) | Comparable at category level, not interchangeable 1:1 | Circumferential elastic retraction; also protects the surgical wound; without screw self-locking mechanism |
Note: before replacing this reference with any alternative, verify ring dimensions, material, hook type, single-use or reusable status and regulatory classification in the corresponding manufacturer’s datasheet. There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.
Selection tips and variants of interest
- Clinical indication: reference WZRR-A-D is intended for anorectal, rectal, general and paediatric surgery. For other specialties, the WZRR-A family includes specific variants: WZRR-A-A (gynaecology, head and neck), WZRR-A-B (ear, nose and throat (ENT)), WZRR-A-C (thyroid, breast and plastic surgery), WZRR-A-E (gynaecology and male urology), WZRR-A-F (urology and thyroid), WZRR-A-G (general surgery, head and neck) and WZRR-A-H (gynaecology and urological surgery).
- Retractor hooks: the system accepts blunt, sharp and rake-type hooks, in sizes S and L. Select the hook according to the tissue to be retracted. The disposable hooks WZRR-P1-S-1 and WZRR-P1-L-1 are the direct accessories for this ring.
- Compatibility: if you already have a ring from another manufacturer, check that the hooks are compatible with the ring’s stepped 3-2-1 mm opening before purchasing them separately.
- Single-use product: being disposable eliminates the risk of cross-contamination and reprocessing costs, ensuring consistent performance in every procedure.
- Volume and tenders: for hospital orders or public tenders, contact our technical department to validate references, special conditions and availability









Reviews