We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Med-Lap 200 ml laparoscopic extraction bag – Sample and fluid recovery (Medline, Ref. 100200)

60,83 €

Med-Lap 200 ml laparoscopic extraction bag, original Medline reference (100200/100200A), designed for the safe recovery of specimens and fluids in minimally invasive surgery. Made of latex-free polyurethane, single-use, with self-opening wire and preloaded system with insertion sleeve and pusher, compatible with 10 and 12 mm trocars.

International shipping. Import duties and taxes are payable by the recipient.

Reference
100200

Description

1. Introduction

The Med-Lap 200 ml extraction bag is a single-use surgical accessory designed for the safe recovery of samples, specimens and fluids during laparoscopic procedures. Its compact volume makes it the ideal solution for low-volume extractions, minor gynaecological surgery and diagnostic procedures, where maximum hygiene, specimen control and simple handling by the surgical team are required.

2. Technical explanation

The Med-Lap bag (Medline range) is manufactured in latex-free polyurethane, a resistant, flexible and sterile material that prevents leaks and minimises the risk of cross-contamination. It incorporates a self-opening wire that keeps the mouth of the bag open, facilitating sample placement and reducing the surgeon’s handling effort. It is presented preloaded in an insertion sleeve accompanied by a pusher, allowing it to be deployed and removed smoothly through the trocar working channel. It is compatible with 10 and 12 mm trocars, the standard diameters in laparoscopic surgery, and is indicated for single-patient use in hospital settings.

3. Technical Specifications

The main technical features of the Med-Lap 200 ml extraction bag are detailed below:

Characteristic Specification
Capacity 200 ml (low-volume extractions)
Material Polyurethane (latex-free)
Use Single-use (disposable)
Compatibility 10 and 12 mm trocars
Opening system Self-opening wire (automatic opening)
Presentation Preloaded with insertion sleeve and pusher
Packaging Box of 5 units (master box of 100 units)
Manufacturer reference 100200 / 100200A (Medline)

4. Equivalences and Cross-References

The Med-Lap 200 ml bag is part of the Medline sample recovery range, available in different volumes to suit each procedure. Within the same family we find references 100400 (400 ml) and 100800 (800 ml) in standard version, as well as the handle variants 110310 (300 ml), 0110320 (550 ml Grip handle) and 0110380 (800 ml handle). This range is comparable to endoscopic recovery bags (endo-bags) from manufacturers such as LEPU Medical, AESCULAP or Steris, which offer equivalent formats for specimen extraction in minimally invasive surgery.

5. Selection tips and variants of interest

Choose the bag capacity according to the expected sample or fluid volume: for small specimens opt for this 200 ml version; for moderate procedures select the 400 ml one; and for bulky extractions, the 800 ml one. If you prioritise an ergonomic grip and additional control during handling, consider the handle variants of the Med-Lap range. Always verify compatibility with the trocar diameter (10 or 12 mm) used in your laparoscopic tower to ensure correct deployment and safe specimen extraction.

Additional information

Material

Latex-free polyurethane

Use

Single-use (disposable)

Compatibility

Trocar of 10 and 12 mm

Opening system

Self-opening wire

Presentation

Preloaded with insertion sleeve and pusher

Packaging

Box of 5 units (master box of 100 units)

Manufacturer reference

100200 / 100200A (Medline)

Capacidad

200 ml

Esterilidad

Sterile

Latex

Latex-free

Reviews

There are no reviews yet.

Be the first to review “Med-Lap 200 ml laparoscopic extraction bag – Sample and fluid recovery (Medline, Ref. 100200)”

Your email address will not be published. Required fields are marked *