Description
1. Product Presentation
The disposable electrosurgical unit Ref. F4390 is the consumable your operating theatre team needs for open surgery: clean cutting, reliable haemostasis and the peace of mind of a sterile single-use product, ready to use in every procedure. Pedal activation frees the surgeon’s hands, who maintains full control of cutting and coagulation with the foot, without letting go of the instrument or distracting attention from the operative field.
Presented in a box of 50 sterile units with factory-mounted F4046 blade, it is the ideal option for hospitals, private clinics, ambulatory surgery centres and purchasing groups seeking the best balance between cost per procedure, safety, constant supply and performance in every intervention.
2. Technical explanation of the equipment and procedure
The pedal-controlled electrosurgical unit is a monopolar electrosurgery pencil: the radiofrequency current generated by the generator (ESU) travels through the cable to the active electrode (the F4046 blade) and concentrates at the point of contact with the tissue, producing the desired surgical effect —cutting, coagulation or mixed— and returning through the patient’s neutral (dispersive) plate.
- Pedal activation: foot control of cutting and coagulation, without manual buttons on the handle, ideal for prolonged manoeuvres and precision dissections.
- F4046 blade: blade electrode in stainless steel, 70 mm long, with a stable edge for repeated dissection and coagulation; shaft of 2.38 mm (3/32″), a standard diameter compatible with the housing of most pencils in the sector and with the F404x range of replaceable electrodes.
- 320 cm cable: wide reach over the surgical field without tension, designed to distribute the table and move the pencil freely.
- 3.2 mm connector: standard monopolar plug for quick and secure connection to the generator socket (adapters F4835–F4838 for other standards).
- Sterile single-use: eliminates the risk of cross-contamination and the costs of cleaning and re-sterilisation.
3. Technical Specifications
| Characteristic | Specification |
| Product type | Disposable electrosurgery pencil (electrosurgical unit), single-use |
| System | Monopolar, cut and coagulation |
| Activation | Foot pedal control (hands-free) |
| Electrode | F4046 stainless steel blade (blade, length 70 mm) |
| Shaft diameter | 2.38 mm (3/32″) |
| Cable length | 320 cm |
| Connector | 3.2 mm monopolar plug |
| Sterility | Sterile, single-use disposable |
| Presentation | Box of 50 units |
| Reference | F4390 |
Compatibility: the 3.2 mm connector fits the standard monopolar socket of most electrosurgical generators on the market. For generators with a different connection standard (Valleylab, 4 mm, Erbe), see the variants with a specific connector (e.g. F4390/4M with 4 mm plug) or the reusable adapters from the F4835–F4838 range.
F4390 family · disposable foot pedal control pencils (shaft Ø 2.38 mm):
| Reference | Cable | Connector | Electrode |
| F4390 | 320 cm | 3.2 mm | Blade F4046 |
| F4390/5 | 500 cm | 3.2 mm | Blade F4046 |
| F4390/A | 320 cm | 3.2 mm | Needle F4048 |
| F4390/P | 320 cm | 3.2 mm | F4044 ball electrode (Ø 4 mm) |
| F4390/L | 320 cm | 3.2 mm | Blade F4050 |
| F4390/AL | 320 cm | 3.2 mm | F4052 needle electrode |
| F4390/PL | 320 cm | 3.2 mm | Sphere F4067 |
| F4390/4M | 320 cm | 4 mm plug | Blade F4046 |
4. Equivalences and Cross-References
Reference F4390 is a distribution code proprietary to Cahnos. There is no manufacturer-validated equivalence table covering this reference; the following rows are functional comparisons verified against official catalogues and regulatory databases (GUDID/FDA), not 1:1 equivalences.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Aspen Surgical (Bovie) | Electrosurgical Foot Control Pencil (disposable foot pedal control pencil with blade electrode, box of 50 units) | ESP7 | Comparable by category (not interchangeable 1:1) | Same product type: disposable pedal-controlled, monopolar, sterile, single-use pencil with stainless steel blade electrode and box of 50 units; accepts standard 3/32″ (2.3 mm) shafts. Differs: 1-pin connector versus 3.2 mm plug, cable length and blade designation (F4046). Code and attributes verified on Aspen Surgical official website and GUDID/FDA. |
| Medline Industries | Pencil, Cautery, Foot Switch, PTFE Blade (cautery pencil with foot switch) | ESFS3002 | Comparable by category (not interchangeable 1:1) | Disposable cauterisation pencil with pedal activation and mounted electrode, presentation of 50 units (2 boxes/master carton). Differs: blade electrode with PTFE coating versus the stainless steel F4046 blade, as well as cable length and connector standard. Code and attributes verified in GUDID/FDA and authorised distribution catalogues (Medline). |
There is no manufacturer-validated equivalence table; consult the technical department before use in tenders. For a 1:1 substitution, always verify field by field: electrode type (blade versus needle or ball), shaft diameter (2.38 mm / 3/32″), cable length, connector type of the installed generator (3.2 mm versus 4 mm, 1 pin or Valleylab), sterility and presentation.
5. Selection tips and variants of interest
- Check your generator connector: this pencil has a 3.2 mm monopolar connector; if your ESU is of another standard (Valleylab, 4 mm, Erbe), choose the variant with specific connector F4390/4M (4 mm plug) or use the reusable adapters from the F4835–F4838 range.
- Choose the electrode geometry according to the technique: the F4046 blade is ideal for cutting and general dissection in open surgery; the same family is completed with the F4048 needle (F4390/A), the F4044 ball (F4390/P), the F4050 blade (F4390/L), the F4052 needle (F4390/AL) and the F4067 ball (F4390/PL), all with 2.38 mm shaft and 320 cm cable; the F4390/5 variant incorporates a 500 cm cable for maximum reach.
- Recommended kits and accessories: F4390/H and F4390/5H (with sterile sheath F4545) and F4390/75 and F4390/5-75 (with tip cleaner F7520); the F4545 sheath allows the pencil to be fixed to the field and the F7520 cleaner maintains electrode performance by removing eschar during the procedure.
- Single-use product: do not re-sterilise or reuse. For institutional volumes or tenders, consult our technical-commercial department.